Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 14 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
3.6.23 Fluid Immersion. When terminated connector assemblies are tested as specified in
4.5.25, the connectors shall show no evidence of damage detrimental to performance or
handling. Some softening and / or parting of the cable clamp elastomeric strain relief is
permissible as long as functionality is not impaired.
3.6.24 Magnetic Permeability. When unmated connector assemblies are tested as specified in
4.5.26, the relative permeability shall be 2.0 maximum.
3.6.25 Solderability.
(Boxmount connectors with pre-tinned PBC mount tails only). When
unterminated boxmount PCB terminals are tested as specified in 4.5.27, the termination
surfaces of the terminals shall be at least 95 percent covered with a continuous new
solder coating.
3.6.26 Industrial Gas.
When terminated, unmated connector assemblies are tested as specified
in 4.5.28, the connectors shall meet the subsequent performance requirements of Table
X1. The contacts shall show no evidence of damage detrimental to the performance or
handling of the connector.
3.6.27 Contact Inductive Load Switching. When terminated, mated connector assemblies are
tested as specified in 4.5.29, they shall meet the room- temperature, after-conditioning,
contact resistance requirements of Table 111.
3.6.28 Overload Current and Circuit Breaker Compatibility. When terminated, mated
connector assemblies are tested as specified in 4.5.30, the connectors shall meet the
room-temperature, after-conditioning, contact resistance requirements of Table III.
3.6.29 Temperature Rise at Rated Current. When mated connector assemblies are tested as
specified in 4.5.31, the temperature rise shall be 100°C maximum.
3.6.30 Insert Material Requirements.
3.6.30.1 Tensile Strength. When tested as specified in 4.5.32.1, the tensile strength shall be
13,000 psi (90 MPa) minimum.
3.6.30.2 Deflection Temperature.
When tested as specified in 4.5.32.2, the deflection
temperature shall be 185°C minimum.
3.6.30.3 Water Absorption. When tested as specified in 4.5.32.3, the water absorption shall be
0.5 percent maximum.
3.6.30.4 Flammability. When tested as specified in 4.5.32.4, the insert material shall meet the
requirements for U.L. flammability rating 94 V-O.
3.6.30.5 Smoke Generation. When tested in accordance with 4.5.32.5, the corrected specific
optical density shall be 15 maximum for each specimen tested.