Nexperia
74AUP1G34
Low-power buffer
74AUP1G34 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 7 — 28 March 2017
10 / 21
11.1 Waveforms and test circuit
mnb153
t
PHL
t
PLH
V
M
V
M
A input
Y output
GND
V
I
V
OH
V
OL
Measurement points are given in Table 9 .
V
OL
and V
OH
are typical output voltage levels that occur with the output load.
Figure 10. The data input (A) to output (Y) propagation delays
Table 9. Measurement points
Supply voltage Output Input
V
CC
V
M
V
M
V
I
t
r
= t
f
0.8 V to 3.6 V 0.5 × V
CC
0.5 × V
CC
V
CC
≤ 3.0 ns
001aac521
DUT
R
T
V
I
V
O
V
EXT
V
CC
R
L
5 kΩ
C
L
G
Test data is given in Table 10 .
Definitions for test circuit:
R
L
= Load resistance.
C
L
= Load capacitance including jig and probe capacitance.
R
T
= Termination resistance should be equal to the output impedance Z
o
of the pulse generator.
V
EXT
= External voltage for measuring switching times.
Figure 11. Test circuit for measuring switching times
Table 10. Test data
Supply voltage Load V
EXT
V
CC
C
L
R
L
[1]
t
PLH
, t
PHL
t
PZH
, t
PHZ
t
PZL
, t
PLZ
0.8 V to 3.6 V 5 pF, 10 pF, 15 pF and 30 pF 5 kΩ or 1 MΩ open GND 2 × V
CC
[1] For measuring enable and disable times R
L
= 5 kΩ, for measuring propagation delays, setup and hold times and pulse width R
L
= 1 MΩ.