AQ1
–2–
ASCTB24E 201509-T
TYPES
1. AQ1 Solid State Relays
Standard packing: Carton 20 pcs., Case 200 pcs.
Notes: *1. Random type also available. Please inquire.
*2. 5 A without heat sink
2. Heat sink for AQ1 solid state relay
Standard packing: Carton 20 pcs., Case 200 pcs.
SPECIFICATIONS
1. Rating (Ambient temperature: 20°C 68°F, Ripple factor: less than 1%)
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When load current is below the rating, refer to “Cautions for Use”.
*5. When heat sink (AQ-HS-5A) is installed. The max. load current is 5 A when heat sink is not installed.
2. Characteristics (Ambient temperature: 20°C 68°F, Ripple factor: less than 1%)
Load Isolation Zero-cross function Type Load current Load voltage Input voltage Part No.
AC Phototriac coupler Zero-cross*
1
Vertical 3 A 75 to 250 V AC 4 to 32 V DC AQ3A2-ZT4/32VDC
Flat 3 A 75 to 250 V AC 4 to 32 V DC AQ3A2-J-ZT4/32VDC
Vertical 10 A*
2
75 to 250 V AC 4 to 32 V DC AQ10A2-ZT4/32VDC
DC Phototransistor –
Vertical 1 A 10 to 200 V DC 3 to 28 V DC AQ1AD2-3/28VDC
Vertical 2 A 3 to 60 V DC 3 to 28 V DC AQ2AD1-3/28VDC
Product name Part No.
Heat sink for AQ10A2-ZT4/32VDC AQ-HS-5A
Type
Item
AC output type
DC output type
RemarksZero-cross
3 A type 10 A type 1 A type 2 A type
Input
side
Input voltage 4 to 32 V DC 3 to 28 V DC
*
1
Input impedance — Approx. 1.6 kΩ
Input current, max. 20 mA —
Drop-out voltage, min. 1.0 V 0.8 V
Load
side
Max. load current*
2
3 A 10 A*
5
1 A 2 A Refer to REFERENCE DATA
“1. Load current vs. ambient
temperature characteristics”.
Load voltage 75 to 250 V AC 10 to 200 V DC 3 to 60 V DC
Non-repetitive surge
current*
3
100 A 5 A
AC: In one cycle at 60 Hz,
DC: 1s
Max. “OFF-state” leakage
current
5 mA 1 mA
AC: at 200 V, 60Hz
DC: When maximum load
voltage is applied.
Max. “ON-state” voltage
drop
1.6 V 1.6 V 2.3 V At Max. carrying current
Min. load current*
4
50 mA 5 mA
Type
Item
AC output
DC output RemarksZero-cross
3 A type 10 A type
Operate time, Max. 1/2 cycle of voltage sine wave + 1 ms 0.5 ms
Release time, Max. 1/2 cycle of voltage sine wave + 1 ms 2 ms
Insulation resistance, Min. 100 M Ω for input, output and case 100 M Ω for input, output at 500 V DC
Breakdown voltage
4,000 Vrms between input and output
2,500 Vrms between input, output and case
3,000 Vrms
between input-output
For 1 minute
Vibration
resistance
Destructive 10 to 55 Hz at double amplitude of 2 mm
10 to 55 Hz
at double amplitude of 2 mm
1 hour for
X, Y, Z axis
Functional 10 to 55 Hz at double amplitude of 2 mm
10 to 55 Hz
at double amplitude of 2 mm
10 minutes for
X, Y, Z axis
Shock
resistance
Destructive Min. 980 m/s
2
{100 G} Min. 980 m/s
2
{100 G}
5 times each for
X, Y, Z axis
Functional Min. 980 m/s
2
{100 G} Min. 980 m/s
2
{100 G}
4 times each for
X, Y, Z axis
Ambient temperature –30°C to +80°C –22°F to +176°F
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn-ON and Turn-OFF) —