AQ2AD1-3/28VDC

–1–
ASCTB24E 201509-T
ORDERING INFORMATION
High capacity up to 10A
PCB terminal type SSR
AQ1 RELAYS
Please contact us about
TÜV certified products.
Certified
AQ1AD2-3/28VDC and
AQ2AD1-3/28VDC
Certified
AQ3A2-ZT4/32VDC,
AQ3A2-J-ZT4/32VDC and
AQ10A2-ZT4/32VDC
Certified
AQ1AD2-3/28VDC
and AQ2AD1-3/28VDC
Certified
AQ10A2-ZT4/32VDC,
AQ3A2-ZT4/32VDC,
and AQ3A2-J-ZT4/32VDC
Certified
AQ1AD2-3/28VDC
and AQ2AD1-3/28VDC
VDE
FEATURES
1. 10A high-capacity realized for PC
board terminal (when using heat sink)
SSR for compact PC boards with 10 A
capacity that is two times greater than
our previous model. It is suitable for long-
life, highly frequent control.
2. VDE (EN60950-1) reinforced
insulation compliant
Fully satisfies demand for safety by
guaranteeing compliance with
EN60950-1 safety standard and featuring
3,000 V reinforced insulation (AQ3A2-
ZT4/32VDC, AQ3A2-J-ZT4/32VDC and
AQ10A2-ZT4/32VDC).
3. Superior anti-vibration and anti-
shock characteristics
The body is molded as a single unit with
flame resistant resin which makes it
highly resistant against vibration and
shock, and gives it superior protection
from environment. The body can also be
washed.
4. Vertical types with SIL terminal
arrangement and flat types are
available.
1) The vertical type is available in
thicknesses of 10 mm (2 A and 3 A types)
and 12 mm (10 A type). Terminal
arrangement is SIL in integral multiples of
2.54 mm (0.1 inch).
2) The height of the flat type is 12 mm.
The terminal arrangement is DIL in
integral multiples of 2.54 mm.
5. Reduced noise generation
The load will operate at close to zero
voltage even when the input signal is
applied during a cycle. Also, even if an
input signal is cancelled during a cycle,
the load is cut off at close to zero current.
For this reason, hardly any noise is
produced and radio frequency
interference (RFI) and electromagnetic
interference (EMI) are kept to a minimum.
6. Built-in snubber circuit prevents
malfunction.
TYPICAL APPLICATIONS
• Printing machines
• Packing machines
Traffic signal control
• Automatic ticket punchers
Terminal equipment of data processing
• Computer peripherals
• NC machines
RoHS compliant
Load current
1 A, 2 A, 3 A, 10 A
AQ
Shape
Nil:
J:
Vertical type
Flat type
Input voltage
3/28 V DC: 3 to 28 V DC
4/32 V DC: 4 to 32 V DC
Load voltage
2:
D1:
D2:
75 to 250 V AC
3 to 60 V DC
10 to 200 V DC
Nil:
ZT:
DC output
Zero-cross AC output (Phototriac coupler)
* Random types are available by custom order.
AQ1
–2–
ASCTB24E 201509-T
TYPES
1. AQ1 Solid State Relays
Standard packing: Carton 20 pcs., Case 200 pcs.
Notes: *1. Random type also available. Please inquire.
*2. 5 A without heat sink
2. Heat sink for AQ1 solid state relay
Standard packing: Carton 20 pcs., Case 200 pcs.
SPECIFICATIONS
1. Rating (Ambient temperature: 20°C 68°F, Ripple factor: less than 1%)
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When load current is below the rating, refer to “Cautions for Use”.
*5. When heat sink (AQ-HS-5A) is installed. The max. load current is 5 A when heat sink is not installed.
2. Characteristics (Ambient temperature: 20°C 68°F, Ripple factor: less than 1%)
Load Isolation Zero-cross function Type Load current Load voltage Input voltage Part No.
AC Phototriac coupler Zero-cross*
1
Vertical 3 A 75 to 250 V AC 4 to 32 V DC AQ3A2-ZT4/32VDC
Flat 3 A 75 to 250 V AC 4 to 32 V DC AQ3A2-J-ZT4/32VDC
Vertical 10 A*
2
75 to 250 V AC 4 to 32 V DC AQ10A2-ZT4/32VDC
DC Phototransistor
Vertical 1 A 10 to 200 V DC 3 to 28 V DC AQ1AD2-3/28VDC
Vertical 2 A 3 to 60 V DC 3 to 28 V DC AQ2AD1-3/28VDC
Product name Part No.
Heat sink for AQ10A2-ZT4/32VDC AQ-HS-5A
Type
Item
AC output type
DC output type
RemarksZero-cross
3 A type 10 A type 1 A type 2 A type
Input
side
Input voltage 4 to 32 V DC 3 to 28 V DC
*
1
Input impedance Approx. 1.6 kΩ
Input current, max. 20 mA
Drop-out voltage, min. 1.0 V 0.8 V
Load
side
Max. load current*
2
3 A 10 A*
5
1 A 2 A Refer to REFERENCE DATA
“1. Load current vs. ambient
temperature characteristics”.
Load voltage 75 to 250 V AC 10 to 200 V DC 3 to 60 V DC
Non-repetitive surge
current*
3
100 A 5 A
AC: In one cycle at 60 Hz,
DC: 1s
Max. “OFF-state” leakage
current
5 mA 1 mA
AC: at 200 V, 60Hz
DC: When maximum load
voltage is applied.
Max. “ON-state” voltage
drop
1.6 V 1.6 V 2.3 V At Max. carrying current
Min. load current*
4
50 mA 5 mA
Type
Item
AC output
DC output RemarksZero-cross
3 A type 10 A type
Operate time, Max. 1/2 cycle of voltage sine wave + 1 ms 0.5 ms
Release time, Max. 1/2 cycle of voltage sine wave + 1 ms 2 ms
Insulation resistance, Min. 100 M Ω for input, output and case 100 M Ω for input, output at 500 V DC
Breakdown voltage
4,000 Vrms between input and output
2,500 Vrms between input, output and case
3,000 Vrms
between input-output
For 1 minute
Vibration
resistance
Destructive 10 to 55 Hz at double amplitude of 2 mm
10 to 55 Hz
at double amplitude of 2 mm
1 hour for
X, Y, Z axis
Functional 10 to 55 Hz at double amplitude of 2 mm
10 to 55 Hz
at double amplitude of 2 mm
10 minutes for
X, Y, Z axis
Shock
resistance
Destructive Min. 980 m/s
2
{100 G} Min. 980 m/s
2
{100 G}
5 times each for
X, Y, Z axis
Functional Min. 980 m/s
2
{100 G} Min. 980 m/s
2
{100 G}
4 times each for
X, Y, Z axis
Ambient temperature –30°C to +80°C –22°F to +176°F
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn-ON and Turn-OFF)
AQ1
–3–
ASCTB24E 201509-T
REFERENCE DATA
1.-(1) Load current vs. ambient temperature
(AC output, 3 A type) Part No.: AQ3A2-ZT4/32VDC
and AQ3A2-J-ZT4/32VDC
Allowable ambient temperature:
–30°C to +80°C –22°F to +176°F
1.-(2) Load current vs. ambient temperature
(AC output, 10 A type) Part No.: AQ10A2-ZT4/32VDC
(A) When not using a heat sink
(B) When using a standard heat sink AQ-HS-5A
(When attached to a heat sink, use a heat conductive
compound (Ex. Toshiba silicone YG6111 or TSK5303)
of similar coating to improve cooling.)
1.-(3) Load current vs. ambient temperature
(DC output, 1 A and 2 A types) Part No.: AQ1AD2-3/
28VDC and AQ2AD1-3/28VDC
Allowable ambient temperature:
–30°C to +80°C –22°F to +176°F
1
2
3
4
5
0
0-30 20 40 60 80 100
Ambient temperature, °C
Load current, A
0 20 40 60 80 100
2
4
6
8
10
0
-30
(A)
(B)
Ambient temperature, °C
Load current, A
0.5
1.0
1.5
2.0
2.5
0
0-30 20 40 60 80
2A type
1A type
Ambient temperature, °C
Load current, A
2.-(1) Non-repetitive surge current vs.
carrying time
(AC output, 3 A and 10 A types)
Part No.: AQ3A2-ZT4/32VDC, AQ3A2-J-ZT4/32VDC
and AQ10A2-ZT4/32VDC
2.-(2) Non-repetitive surge current vs.
carrying time
(DC output) Part No.: AQ1AD2-3/28VDC and
AQ2AD1-3/28VDC
3.-(1) Input current vs. input voltage
characteristics
(AC output, 3 A and 10 A types)
Part No.: AQ3A2-ZT4/32VDC, AQ3A2-J-ZT4/32VDC
and AQ10A2-ZT4/32VDC
0
50
25
100
75
125
1 10 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
2
4
6
8
10
12
14
16
18
20
22
1 50 500 1,000100
Carrying time, ms
Non-repetitive surge current, A
5
10
15
20
25
0
100 5 15 20 25 30 35
Input voltage, V
Input current, mA
3.-(2) Input current vs. input voltage
characteristics
(DC output)
Part No.: AQ1AD2-3/28VDC and AQ2AD1-3/28VDC
4.-(1) Load current vs. ambient temperature
characteristics for adjacent mounting
(AC output, 3A vertical type)
Part No.: AQ3A2-ZT4/32VDC
4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting
(AC output, 10A type)
Part No.: AQ10A2-ZT4/32VDC (without heat sink)
2
4
6
8
10
12
14
16
18
20
22
24
26
28
0 4 8 121620242830
Input voltage, V
Input current, mA
5
4
3
2
1
0
200
-20-30
40 60 10080
=15.24mm
.600inch
= Adjacent mounting pitch
Ambient temperature, °C
Load current, A
6
5
4
3
2
1
0
200
-20-30
40 60 80 100
= Adjacent mounting pitch
=20.32mm
.800inch
Load current, A
Ambient temperature, °C

AQ2AD1-3/28VDC

Mfr. #:
Manufacturer:
Panasonic
Description:
Solid State Relays - PCB Mount 2A 3/28V Non-Zero Cross
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet