DC and AC parameters M27C2001
13/25
4 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Tabl e 5 , Operating and AC Measurement Conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Figure 6. AC Testing Input Output Waveform
Table 5. AC Measurement conditions
High Speed Standard
Input Rise and Fall Times ≤ 10ns ≤ 20ns
Input Pulse Voltages 0 to 3V 0.4V to 2.4V
Input and Output Timing Ref. Voltages 1.5V 0.8V and 2V
Table 6. Capacitance
(1)
(T
A
= 25°C, f = 1 MHz)
1. Sampled only, not 100% tested
Symbol Parameter Test Condition Min Max Unit
C
IN
Input Capacitance V
IN
= 0V 6 pF
C
OUT
Output Capacitance V
OUT
= 0V 12 pF
AI01822
3V
High Speed
0V
1.5V
2.4V
Standard
0.4V
2.0V
0.8V