PS2381-1
R08DS0134EJ0200 Rev.2.00 Page 11 of 12
Oct 30, 2015
SPECIFICATION OF VDE MARKS LICENSE DOCUMENT
Parameter Symbol Spec. Unit
Climatic test class (IEC 60068-1/DIN EN 60068-1) 40/115/21
Dielectric strength
maximum operating isolation voltage
Test voltage (partial discharge test, procedure a for type test and random test)
U
pr = 1.6 UIORM, Pd 5 pC
UIORM
Upr
1 130
1 808
V
peak
Vpeak
Test voltage (partial discharge test, procedure b for all devices)
U
pr = 1.875 UIORM, Pd 5 pC
U
pr 2 119 Vpeak
Highest permissible overvoltage UTR 8 000 Vpeak
Degree of pollution (DIN EN 60664-1 VDE0110 Part 1) 2
Comparative tracking index (IEC 60112/DIN EN 60112 (VDE 0303 Part 11)) CTI 175
Material group (DIN EN 60664-1 VDE0110 Part 1) III a
Storage temperature range Tstg –40 to +125 C
Operating temperature range TA –40 to +115 C
Isolation resistance, minimum value
V
IO = 500 V dc at TA = 25C
V
IO = 500 V dc at TA MAX. at least 100C
Ris MIN.
Ris MIN.
10
12
10
11
Safety maximum ratings (maximum permissible in case of fault, see thermal derating
curve)
Package temperature
Current (input current I
F, Psi = 0)
Power (output or total power dissipation)
Isolation resistance
V
IO = 500 V dc at TA = Tsi
Tsi
Isi
Psi
Ris MIN.
175
400
700
10
9
C
mA
mW