DAC8426
–3–
REV. C
CAUTION
1. Do not apply voltages higher than V
DD
or less than V
SS
po-
tential on any terminal.
2. The digital control inputs are zener-protected; however,
permanent damage may occur on unprotected units from
high-energy electrostatic fields. Keep units in conductive
foam at all times until ready to use.
3. Do not insert this device into powered sockets. Remove
power before insertion or removal.
4. Stresses above those listed under “Absolute Maximum Rat-
ings” may cause permanent damage to device.
Burn-In Circuit
ABSOLUTE MAXIMUM RATINGS
V
DD
to AGND or DGND . . . . . . . . . . . . . . . . .–0.3 V, +17 V
V
SS
to AGND or DGND . . . . . . . . . . . . . . . . . . . . . –7 V, V
DD
V
DD
to V
SS
. . . . . . . . . . . . . . . . . . . . . . . . . . . .–0.3 V, +24 V
AGND to DGND . . . . . . . . . . . . . . . . . . . . . . . .–0.3 V, +5 V
Digital Input Voltage to DGND . . . . . . . . . . . . . –0.3 V, V
DD
V
REF
OUT to AGND
1
. . . . . . . . . . . . . . . . . . . . . –0.3 V, V
DD
V
OUT
to AGND
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . V
SS
, V
DD
Operating Temperature
Military AR/BR . . . . . . . . . . . . . . . . . . . . –55°C to +125°C
Extended Industrial ER/EP/FR/FP/FS . . . . –40°C to +85°C
Maximum Junction Temperature . . . . . . . . . . . . . . . . +150°C
Storage Temperature . . . . . . . . . . . . . . . . . . –65°C to +150°C
Lead Temperature (Soldering, 60 sec) . . . . . . . . . . . . +300°C
THERMAL RESISTANCE
Package Type u
JA
2
u
JC
Units
20-Pin Cerdip (R) 70 7 °C/W
20-Pin Plastic DIP (P) 61 24 °C/W
20-Pin SOL(S) 80 22 °C/W
NOTES
1
Outputs may be shorted to any terminal provided the package power dissipation
is not exceeded. Typical output short-circuit current to AGND is 50 mA.
2
θ
JA
is specified for worst case mounting conditions, i.e., θ
JA
is specified for de-
vice in socket for cerdip and P-DIP packages; θ
JA
is specified for device sol-
dered to printed circuit board for SOL package.
20-Pin Cerdip
(R Suffix)
20-Pin Epoxy DIP
(P Suffix)
20-Pin SOL
(S Suffix)
PIN CONNECTIONS
ORDERING GUIDE
1
Model Total Unadjusted Error Temperature Range Package Description
DAC8426AR
2
±1 LSB –55°C to +125°C 20-Pin Cerdip (Q-20)
DAC8426ER ±1 LSB –40°C to +85°C 20-Pin Cerdip (Q-20)
DAC8426EP ±1 LSB –40°C to +85°C 20-Pin Plastic DIP (N-20)
DAC8426BR
2
±2 LSB –55°C to +125°C 20-Pin Cerdip (Q-20)
DAC8426FR ±2 LSB –40°C to +85°C 20-Pin Cerdip (Q-20)
DAC8426FP ±2 LSB –40°C to +85°C 20-Pin Plastic DIP (N-20)
DAC8426FS
3
±2 LSB –40°C to +85°C 20-Lead SOL (R-20)
NOTES
1
Burn-in is available on commercial and industrial temperature range parts in cerdip, plastic DIP, and TO-can packages.
2
For devices processed in total compliance to MIL-STD-883, add /883 after part number. Consult factory for 883 data sheet.
3
For availability and burn-in information on SO and PLCC packages, contact your local sales office.