MY
MY
4
Characteristics
Item All
relays
Contact resistance
50 m
:
max.
Operate time
20 ms max.
Release time
20 ms max.
Max. operating frequency
Mechanical:
18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
:
min. (at 500 VDC)
Dielectric strength
2,000 V
AC, 50/60 Hz for 1 min (1,000 V
AC
between contacts of same polarity)
V
ibration resistance
Destruction:
10 to 55 Hz, 1.0-mm double amplitude
Malfunction:
10 to 55 Hz, 1.0-mm double amplitude
Shock resistance
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction:
200 m/s
2
(approx. 20G)
Life expectancy
See following table.
Ambient operating temperature*
Single- and double-pole standard, bifurcated-contact, test-button, relays:
–55q
C to 70
q
C (with no icing)
All other relays: –55
q
C to 60
q
C (with no icing)
Ambient operating humidity
35% to 85%
Weight
Approx. 85 g
Note:
The values given above are initial values.
Life Expectancy Characteristics
Relays Mechanical
life
(at 18,000 operations/hr)
Electrical life
(at 1,800 operations/hr under rated load)
Normal,
With test button (except relays
with operation
indicator), With CR
AC
50,000,000 operations min.
DC:
100,000,000 operations min.
1-,2-,3-pole:
500,000 operations min.
4-pole:
200,000 operations min.
With operation indicator or built-in diode
AC
50,000,000 operations min.
DC:
100,000,000 operations min.
1-,2-,3-pole:
500,000 operations min.
4-pole:
200,000 operations min.
With bifurcated contacts
2-pole:
50,000,000 operations min.
4-pole:
2-pole:
200,000 operations min.
4-pole:
100,000 operations min.
Note:
See following tables for real load life expectancies.
Life Expectancies Under Real Loads
MY2
Rated
voltage
Load type
Conditions
Operating frequency
Electrical life
100 V
AC
AC motor
50 W
, 100 V
AC single-phase with
2.8-A inrush current, 0.4-A carry
current
ON for 2 s, OFF for 30 s
100,000 operations
50 W
, 100 V
AC single-phase with
1.6-A inrush current, 1-A carry current
ON for 1 s, OFF for 30 s
300,000 operations
AC solenoid
24 W with 1-A carry current ON for 1.5 s, OFF for 1.5 s
4,000,000 operations
MY4
Rated voltage
Load type
Conditions
Operating frequency
Electrical life
100 V
AC
AC solenoid
50 V
A with 2-A inrush current, 0.7A
carry current
ON for 1 s, OFF for 3 s
25,000 operations
DC magnetic
switch
25 W with L/R = 40 ms , 0.2-A carry
current
AC magnetic
switch
35 V
A with 1.5-A inrush current,
0.35-A carry current
500,000 operations
24 VDC
DC solenoid 40 W with L/R = 10 ms, 1.6-A carry
current
ON for 0.5 s, OFF for 1.5 s
5,000,000 operations
30 W with L/R = 10 ms with 0.34-A
carry current
ON for 0.5 s, OFF for 1.5 s
6,000,000 operations
MY
MY
5
Approved by Standards
Some MY Relays are available in models meeting various safety
standards.
When ordering, you must specify
the desired standards.
Refer
to
Ordering Information
for specific models. Note that the rat
-
ing recognized by the various standards sometimes vary from the
ratings
of the individual relays.
UL 508 Recognitions (File No. 41515)
No.
of poles
Coil ratings Contact ratings
2
6 to 240 V
AC
6 to 125 VDC
5 A, 120 V
AC resistive load
5 A, 28 VDC resistive load
5 A, 240 V
AC inductive load
3
5 A, 28 VDC resistive load
5 A, 240 V
AC inductive load
4
6 to 240 V
AC
6 to 125 VDC
3 A 28 VDC resistive load
3 A 120 V
AC inductive load
1.5 A, 240 V
AC inductive load
5 A, 240 V
AC inductive load
(between contacts of same
polarity)
5 A, 28 VDC resistive load
(between contacts of same
polarity)
0.2 A, 120 VDC
CSA 22.2 No. 0 and No.14 (File No. LR31928)
Model No.
of
poles
Coil
ratings
Contact ratings
MY
2, 3 6 to 240
VAC
6 to 120
VDC
5 A, 28 VDC resistive
load
5 A, 240 V
AC inductive
load
4
3 A, 28VDC resistive
load
3 A, 240 V
AC inductive
load
5 A, 240 V
AC inductive
load (between contacts
of same polarity)
5 A, 28 VDC resistive
load (between contacts
of same polarity)
0.2 A, 120 VDC
LR (No. 563KOB-204524)
Model No.
of
poles
Coil
ratings
Contact ratings
MY -LR
2
6 to 240
VAC
6 to 120
VDC
2 A, 30 VDC inductive
load
2 A, 200 V
AC inductive
load
4
1.5 A, 30 VDC
inductive load
0.8 A, 200 V
AC
inductive load
1.5 A, 1
15 V
AC
inductive load
Engineering Data
Maximum Switching Capacity
MY2, MY3
Switching
voltage (V)
Switching current (A)
AC resistive load
DC resistive
load
DC inductive
load (L/R = 7 ms)
AC inductive load
(cosf
= 0.4)
MY
MY
6
MY4, MY4Z
Switching
voltage (V)
Switching current (A)
AC resistive
load
DC resis-
tive load
DC Inductive
load
L/R = 7 ms
AC inductive load
(cosf
= 0.4)
Life Expectancy
Switching current (A)
MY2, MY3 (Inductive Loads)
Switching current (A)
MY2, MY3 (Resistive
Loads)
110 VAC resistive load
220 VAC
resistive load
24 VDC resistive
load
24 VDC inductive load
(L/R = 7 ms)
110 VAC inductive
load (cosf
= 0.4)
220 VAC in-
ductive load
(cosf
= 0.4)
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Switching current (A)
MY4 (Inductive Loads)
Switching current (A)
MY4 (Resistive Loads)
110 VAC resistive
load
30 VDC resistive
load
220 VAC resis-
tive load
110 VAC Inductive
load
220 VAC Inductive
load
30 VDC Inductive
load
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Switching current (A)
MY4Z (Inductive Loads)
Switching current (A)
MY4Z (Resistive Loads)
220 VAC resis-
tive load
24 VDC resistive load
110 VAC (cosf
= 0.4)
24 VDC
L/R = 7 ms
220 VAC (cosf
= 0.4)
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Life expectancy (x10 operations)
3
1,000
500
100
5,000

MY4-02 AC12

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
General Purpose Relays GP Relay
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: