ACPL-K370, ACPL-K376
Isolated Voltage/Current Detector
Data Sheet
Description
The ACPL-K370 and ACPL-K376 are voltage/current
threshold detection optocouplers. The ACPL-K376 is a low-
current version of the ACPL-K370. To obtain lower current
operation, the ACPL-K376 uses a high-eciency AlGaAs
LED which has higher light output at lower drive currents.
Both devices have a threshold sensing input buer IC
that allows threshold levels to be set by a single external
resistor over a wide range of input voltages.
The input buer has several performance enhancing
features: hysteresis for extra noise immunity and
switching immunity, a diode bridge for easy use with AC
input signals, and internal clamping diodes to protect the
buer and LED from over-voltage and over-current tran-
sients. Because threshold sensing is done prior to driving
the LED, variations in optical coupling from the LED to the
detector will not eect the threshold levels.
The ACPL-K370 input buer IC has a nominal turn-on
threshold of 3.8 V(V
TH+
) and 2.77 mA (I
TH+
). The buer
IC for the ACPL-K376 is designed for lower input current.
The nominal turn-on threshold for the ACPL-K376 is 3.8 V
(V
TH+
) and 1.32 mA (I
TH+
), which reduces power dissipa-
tion by 52%.
The high-gain output stage features an open-collector
output for both TTL compatible saturation voltages and
CMOS compatible breakdown voltages.
By combining many unique functions in a single package, the
ACPL-K370 and ACPL-K376 are ideal components for indus-
trial control computer input boards and other applications
where a predetermined input threshold level is needed.
Functional Diagram
Features
x ± 5% voltage detection accuracy
x Wide AC or DC detection range: up to 1140 Vpeak
x User congurable single/dual detection levels
x Built-in hysteresis improves noise immunity
x Very low threshold current: 1.32 mA (ACPL-K376)
x Logic compatible output
x Wide output supply voltage: 2 V to 18 V
x –40°C to +105°C operating temperature range
x SSO-8 package with 8 mm creepage and clearance
x Safety and regulatory approval:
IEC/EN/DIN EN 60747-5-5: 1140 Vpeak working
insulation voltage
UL 1577: 5000 Vrms/1minute double protection
rating
CSA: Component Acceptance Notice #5
Applications
x Limit switch sensing
x Low voltage detector
x AC mains and DC-link voltage detection
x Relay contact monitor
x Relay coil voltage monitor
x Current sensing
x Microprocessor interfacing
x Telephone ring detection
Connection Diagram
1
2
3
4
8
7
6
5
AC1
DC+
DC
AC2
V
CC
V
O
GND
TRUTH TABLE
(POSITIVE LOGIC)
INPUT
H
L
OUTPUT
L
H
NC
I
CC
I
O
D1
D2
D3
D4
Figure 1. Functional Diagram
AC/DC
POWER
CONTROLLER
ISOLATION BARRIER
ACPL-K370
ACPL-K376
GND1 GND2
R
X
Figure 2. Connection Diagram
2
Table 1. Ordering Information
The ACPL-K370 and ACPL-K376 are UL recognized with 5000 Vrms for 1 minute per UL1577.
Part number
Option
Package Surface Mount
Tape
& Reel
IEC/EN/
DIN EN
60747-5-2 Quantity
RoHS
Compliant
ACPL-K370
ACPL-K376
-000E
Stretched
SO-8
X
80 per tube
-060E
XX
80 per tube
-500E
XX
1000 per reel
-560E
XXX
1000 per reel
To form a complete ordering part number, choose a part number from the part number column and combine it with the
desired option from the option column.
Example 1:
ACPL-K370-560E orders an RoHS compliant part with an IEC/EN/DIN EN 60747-5-5 certication and Tape & Reel
packaging.
Package Outline Drawings
Stretched SO-8 Package (SSO-8)
5.850 ± 0.50
(0.230 ± 0.010)
5
678
4321
Dimensions in millimeters and (inches).
Lead coplanarity = 0.1 mm (0.004 inches).
6.807 ± 0.127
(0.268 ± 0.005)
RECOMMENDED LAND PATTERN
12.650 (0.5)
1.905 (0.1)
3.180 ± 0.127
(0.125 ± 0.005)
0.381 ± 0.130
(0.015 ± 0.005)
1.270
(0.050) BSG
(0.453 ± 0.010)
(0.008 ± 0.004)
(0.0295 ± 0.010)
0.200 ± 0.100
0.750 ± 0.250
11.50 ± 0.250
(0.063 ± 0.005)
1.590 ± 0.127
(0.018)
0.450
45°
Z = OPTION CODE
[1]
RoHS-COMPLIANCE
INDICATOR
PART NUMBER
DATE CODE
K370
Z
YYWW
Note 1. “V = Options comprise 060; other options are not marked.
Figure 3.
3
Recommended Lead-Free IR Soldering Prole
The recommended reow soldering prole is per JEDEC Standard J-STD-020 (latest revision). Non-halide ux should be
used.
Table 2. Insulation Related Specications
Parameter Symbol Value Units Conditions
Minimum External Air Gap
(Clearance)
L(IO1) 8 mm L(IO1)
Minimum External Tracking Path
(Creepage)
L(IO2) 8 mm Measured from input terminals to output terminals
Minimum Internal Plastic Gap
(Clearance)
0.08 mm Through insulation distance conductor to conductor
Tracking Resistance CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group
(per DIN VDE 0109)
IIIa Material Group DIN VDE 0109
Regulatory Information
The ACPL-K370/K376 is approved by the following organizations:
IEC/EN/DIN EN 60747-5-5 (with option 060)
Approved with a maximum working insulation voltage of
V
IORM
= 1140 Vpeak, and with a highest allowable over-
voltage of V
IOTM
= 8000 Vpeak.
UL
Approval under the UL 1577 component recognition
program up to V
ISO
= 5000 V
RMS
/ 1 minute. File E55361.
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.

ACPL-K370-500E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Logic Output Optocouplers Optocoupler
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS