ADM3054 Data Sheet
Rev. D | Page 4 of 20
TIMING SPECIFICATIONS
Each voltage is relative to its respective ground, 3.0 V ≤ V
DD1
≤ 5.5 V. T
A
= −40°C to +125°C, 4.75 V ≤ V
DD2
≤ 5.25 V, unless otherwise noted.
Table 2.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
DRIVER
Maximum Data Rate 1 Mbps
Propagation Delay TxD On to Bus Active t
onTxD
90 ns R
L
= 60 Ω, C
L
= 100 pF, see Figure 23
and Figure 27
Propagation Delay TxD Off to Bus Inactive t
offTxD
120 ns R
L
= 60 Ω, C
L
= 100 pF, see Figure 23
and Figure 27
RECEIVER
Propagation Delay TxD On to Receiver Active t
onRxD
200 ns R
L
= 60 Ω, C
L
= 100 pF, see Figure 23
and Figure 27
Propagation Delay TxD Off to Receiver Inactive t
offRxD
250 ns R
L
= 60 Ω, C
L
= 100 pF, see Figure 23
and Figure 27
POWER-UP
Enable Time, V
DD2
High to V
DD2SENSE
Low t
SE
300 µs See Figure 26
Disable Time, V
DD2
Low to V
DD2SENSE
High t
SD
10 ms See Figure 26
Data Sheet ADM3054
Rev. D | Page 5 of 20
REGULATORY INFORMATION
Table 3. ADM3054 Approvals
Organization Approval Type Notes
UL
Recognized under the component recognition
program of Underwriters Laboratories, Inc.
In accordance with UL 1577, each ADM3054 is proof tested by
applying an insulation test voltage ≥ 6000 V rms for 1 second
VDE Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
In accordance with DIN V VDE V 0884-10, each ADM3054 is proof
tested by applying an insulation test voltage ≥ 1590 V peak for
1 second (partial discharge detection limit = 5 pC)
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 4.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (External Clearance) L(I01) 8.0 mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 7.6 mm Measured from input terminals to output terminals,
shortest distance along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303-1
Isolation Group II Material group (DIN VDE 0110)
ADM3054 Data Sheet
Rev. D | Page 6 of 20
VDE 0884 INSULATION CHARACTERISTICS
This isolator is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data must be ensured
by means of protective circuits.
Table 5.
Description Test Conditions/Comments Symbol Characteristic Unit
CLASSIFICATIONS
Installation Classification per DIN VDE 0110 for
Rated Mains Voltage
≤150 V rms I to IV
≤300 V rms
I to IV
≤400 V rms I to III
Climatic Classification 40/125/21
Pollution Degree DIN VDE 0110 2
VOLTAGE
Maximum Working Insulation Voltage V
IORM
846 V peak
Input-to-Output Test Voltage, Method B1 V
IORM
× 1.875 = V
PR
, 100% production tested,
t
m
= 1 sec, partial discharge < 5 pC
V
PR
1590 V peak
Input-to-Output Test Voltage, Method A
After Environmental Tests, Subgroup 1 V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
1357 V peak
After Input and/or Safety Test,
Subgroup 2/Subgroup 3:
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
1018 V peak
Highest Allowable Overvoltage V
TR
6000 V peak
SAFETY LIMITING VALUES
Case Temperature T
S
150 °C
Input Current I
S, INPUT
265 mA
Output Current I
S, OUTPUT
335 mA
Insulation Resistance at T
S
R
S
>10
9
Ω

ADM3054WBRWZ-RL7

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
DGTL ISOLATOR 5KV 3CH CAN 16SOIC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet