Data Sheet ADM3054
Rev. D | Page 5 of 20
REGULATORY INFORMATION
Table 3. ADM3054 Approvals
Organization Approval Type Notes
Recognized under the component recognition
program of Underwriters Laboratories, Inc.
In accordance with UL 1577, each ADM3054 is proof tested by
applying an insulation test voltage ≥ 6000 V rms for 1 second
VDE Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
In accordance with DIN V VDE V 0884-10, each ADM3054 is proof
tested by applying an insulation test voltage ≥ 1590 V peak for
1 second (partial discharge detection limit = 5 pC)
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 4.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (External Clearance) L(I01) 8.0 mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 7.6 mm Measured from input terminals to output terminals,
shortest distance along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303-1
Isolation Group II Material group (DIN VDE 0110)