74AHC1G4210GWH

Nexperia
74AHC1G4210
10-stage divider and oscillator
10 Static characteristics
Table 6. Static characteristics
Voltages are referenced to GND (ground = 0 V).
25 °C -40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ Max Min Max Min Max
Unit
X1
V
CC
= 2.0 V 1.7 - - 1.7 - 1.7 - V
V
CC
= 3.0 V 2.4 - - 2.4 - 2.4 - V
V
IH
HIGH-level
input voltage
V
CC
= 5.5 V 4.4 - - 4.4 - 4.4 - V
X1
V
CC
= 2.0 V - - 0.3 - 0.3 - 0.3 V
V
CC
= 3.0 V - - 0.6 - 0.6 - 0.6 V
V
IL
LOW-level
input voltage
V
CC
= 5.5 V - - 1.1 - 1.1 - 1.1 V
Q; V
I
= V
IH
or V
IL
I
O
= -50 μA; V
CC
= 2.0 V 1.9 2.0 - 1.9 - 1.9 - V
I
O
= -50 μA; V
CC
= 3.0 V 2.9 3.0 - 2.9 - 2.9 - V
I
O
= -50 μA; V
CC
= 4.5 V 4.4 4.5 - 4.4 - 4.4 - V
I
O
= -4.0 mA; V
CC
= 3.0 V 2.58 - - 2.48 - 2.40 - V
I
O
= -8.0 mA; V
CC
= 4.5 V 3.94 - - 3.8 - 3.70 - V
X2; V
I
= V
IH
or V
IL
I
O
= -50 μA; V
CC
= 2.0 V 1.9 2.0 - 1.9 - 1.9 - V
I
O
= -50 μA; V
CC
= 3.0 V 2.9 3.0 - 2.9 - 2.9 - V
I
O
= -50 μA; V
CC
= 4.5 V 4.4 4.5 - 4.4 - 4.4 - V
I
O
= -2.0 mA; V
CC
= 3.0 V 2.58 - - 2.48 - 2.40 - V
V
OH
HIGH-level
output voltage
I
O
= -3.0 mA; V
CC
= 4.5 V 3.94 - - 3.8 - 3.70 - V
Q; V
I
= V
IH
or V
IL
I
O
= 50 μA; V
CC
= 2.0 V - 0 0.1 - 0.1 - 0.1 V
I
O
= 50 μA; V
CC
= 3.0 V - 0 0.1 - 0.1 - 0.1 V
I
O
= 50 μA; V
CC
= 4.5 V - 0 0.1 - 0.1 - 0.1 V
I
O
= 4.0 mA; V
CC
= 3.0 V - - 0.36 - 0.44 - 0.55 V
I
O
= 8.0 mA; V
CC
= 4.5 V - - 0.36 - 0.44 - 0.55 V
X2; V
I
= V
IH
or V
IL
I
O
= 50 μA; V
CC
= 2.0 V - 0 0.1 - 0.1 - 0.1 V
I
O
= 50 μA; V
CC
= 3.0 V - 0 0.1 - 0.1 - 0.1 V
I
O
= 50 μA; V
CC
= 4.5 V - 0 0.1 - 0.1 - 0.1 V
I
O
= 2.0 mA; V
CC
= 3.0 V - - 0.36 - 0.44 - 0.55 V
V
OL
LOW-level
output voltage
I
O
= 3.0 mA; V
CC
= 4.5 V - - 0.36 - 0.44 - 0.55 V
I
I
input leakage
current
X1; V
I
= 5.5 V or GND;
V
CC
= 0 V to 5.5 V
- - 0.1 - 1.0 - 2.0 μA
74AHC1G4210 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2018. All rights reserved.
Product data sheet Rev. 3 — 25 April 2018
4 / 12
Nexperia
74AHC1G4210
10-stage divider and oscillator
25 °C -40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ Max Min Max Min Max
Unit
I
CC
supply current V
I
= V
CC
or GND; I
O
= 0 A;
V
CC
= 5.5 V
- - 1.0 - 10 - 40 μA
C
I
input
capacitance
X1 - 3 8 - 8 - 8 pF
11 Dynamic characteristics
Table 7. Dynamic characteristics
GND = 0 V; t
r
= t
f
= ≤ 3.0 ns. For test circuit see Figure 7. For waveforms see Figure 5 and Figure 6.
25 °C -40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ Max Min Max Min Max
Unit
X1 to X2
[1]
V
CC
= 3.0 V to 3.6 V
[2]
C
L
= 15 pF - 3 7 1 11 1 13 ns
C
L
= 50 pF - 7 13 1 16 1 18 ns
V
CC
= 4.5 V to 5.5 V
[3]
C
L
= 15 pF - 2 5 1 7 1 9 ns
C
L
= 50 pF - 6 10 1 11 1 12 ns
X1 to Q
[1]
V
CC
= 3.0 V to 3.6 V
[2]
C
L
= 15 pF - 24 41 1 50 1 59 ns
C
L
= 50 pF - 26 45 1 53 1 63 ns
V
CC
= 4.5 V to 5.5 V
[3]
C
L
= 15 pF - 17 27 1 33 1 39 ns
t
pd
propagation
delay
C
L
= 50 pF - 19 30 1 38 1 44 ns
X1 HIGH or LOW
V
CC
= 3.0 V to 3.6 V 4 - - 5 - 7 - ns
t
W
pulse width
V
CC
= 4.5 V to 5.5 V 3 - - 4 - 5 - ns
X1
V
CC
= 3.3 V 125 - - 100 - 70 - MHz
f
max
maximum
frequency
V
CC
= 5 V 165 - - 125 - 100 - MHz
C
L
= 50 pF; f
i
= 1 MHz;
V
I
= GND to V
CC
[4]
V
CC
= 3.3 V - 4 - - - - - pF
C
PD
power
dissipation
capacitance
V
CC
= 5 V - 5 - - - - - pF
[1] t
pd
is the same as t
PLH
and t
PHL
.
[2] Typical values are measured at V
CC
= 3.3 V.
[3] Typical values are measured at V
CC
= 5.0 V.
[4] C
PD
is used to determine the dynamic power dissipation P
D
(μW).
P
D
= C
PD
x V
CC
2
x f
i
+ C
L
x V
CC
2
x f
i
/1024 where:
f
i
= input frequency in MHz; C
L
= output load capacitance in pF; V
CC
= supply voltage in Volt.
74AHC1G4210 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2018. All rights reserved.
Product data sheet Rev. 3 — 25 April 2018
5 / 12
Nexperia
74AHC1G4210
10-stage divider and oscillator
11.1 Waveforms and test circuit
aaa-022703
X1 input
X2 output
t
PHL
t
PLH
GND
V
I
V
M
V
M
V
OH
V
OL
t
W
Measurement points are given in Table 8.
V
OL
and V
OH
are typical output voltage levels that occur with
the output load.
Figure 5.  Input X1 to output X2 propagation delay times
t
PHL
t
PLH
V
M
V
M
1/f max
aaa-022704
X1 input
Q output
GND
V
I
V
OH
V
OL
Measurement points are given in Table 8.
V
OL
and V
OH
are typical output voltage levels that occur with
the output load.
Figure 6.  Input X1 to output Q propagation delay times
Table 8. Measurement points
Inputs Output
V
I
V
M
V
M
GND to V
CC
0.5 × V
CC
0.5 × V
CC
mna101
V
CC
V
I
V
O
R
T
C
L
PULSE
GENERATOR
DUT
Test data is given in Table 7. Definitions for test circuit:
C
L
= Load capacitance including jig and probe capacitance.
R
T
= Termination resistance should be equal to output impedance Z
o
of the pulse generator.
Figure 7.  Test circuit for measuring switching times
74AHC1G4210 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2018. All rights reserved.
Product data sheet Rev. 3 — 25 April 2018
6 / 12

74AHC1G4210GWH

Mfr. #:
Manufacturer:
Nexperia
Description:
Multipliers / Dividers 74AHC1G4210GW/UMT5/REEL 7" Q3/
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet