1996 Sep 04 16
Philips Semiconductors Product specification
Light position controller TDA3629
Table 2 General test conditions for immunity measurements
Notes
1. The typical value is
2. For definition see
“ISO/DIS 11452-1”
, annex B.
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
General
T
amb
ambient temperature 18 − 28
o
C
V
bat
battery voltage 12.5 − 13.5 V
V
diff
absolute differential output voltage
(DC value)
0 1.0 V
f
start
start frequency − 250 − kHz
f
stop
stop frequency − 1000 − MHz
f
n
frequency steps from 250 kHz to 1 MHz − − 100 kHz
from 1 to 10 MHz; 9 steps
(logarithmic): n = 0 to 8
− note 1 − MHz
from 10 to 200 MHz − − 2 MHz
from 200 to 1000 MHz − − 20 MHz
V
IL(rms)
immunity voltage level (RMS value) from 250 kHz to 1 MHz 5 − − V
from 1 MHz to 5 MHz 10 − − V
from 5 MHz to 1 GHz 15 − − V
V
TL(max)
maximum test voltage level − 24 − V
V
START(rms)
voltage start level (RMS value) 2 4 6 V
V
STEP(rms)
voltage level step (RMS value) − 2 − V
Q
TL
relative accuracy of test level −10 − +10 %
t
dwell
dwell time 2 − − s
RF-voltage characteristic; note 2
f
M(AM)
AM modulation frequency constant peak level − 1 − kHz
m
D
modulation depth constant peak level − 0 − %
1 10
n
9
-