Data Sheet ADRF5020
Rev. A | Page 5 of 12
ABSOLUTE MAXIMUM RATINGS
For recommended operating conditions, see Table 1.
Table 2.
Parameter Rating
Supply Voltage
Positive −0.3 V to +5.5 V
Negative −2.75 V to +0.3 V
Digital Control Input Voltage −0.3 V to V
DD
+ 0.3 V
RF Input Power
1
(f = 600 MHz to 30 GHz,
CASE
Terminated Path 25 dBm
Hot Switching 21 dBm
Temperature
Junction (T
J
) 135°C
Storage −65°C to +150°C
Reflow (MSL3 Rating)
2
260°C
Junction to Case Thermal Resistance (θ
JC
)
Through Path 420°C/W
Terminated Path 160°C/W
ESD Sensitivity
HBM 1 kV (Class 1)
1
For power derating at frequencies less than 600 MHz, see Figure 2 to Figure 4.
2
See the Ordering Guide section.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Only one absolute maximum rating can be applied at any one
time.
POWER DERATING CURVES
4
–14
–12
–10
–8
–6
–4
–2
0
2
POWER DERATING (dB)
FREQUENCY (Hz)
10k 1M 100M 10G100k 10M
1G
14581-002
Figure 2. Power Derating for Through Path vs. Frequency, T
CASE
= 85°C
4
–14
–12
–10
–8
–6
–4
–2
0
2
POWER DERATING (dB)
FREQUENCY (Hz)
10k
1M
100M 10G
100k
10M 1G
14581-003
Figure 3. Power Derating for Terminated Path vs. Frequency, T
CASE
= 85°C
4
–14
–12
–10
–8
–6
–4
–2
0
2
POWER DERATING (dB)
14581-004
FREQUENCY (Hz)
10k 1M 100M 10G100k 10M 1G
Figure 4. Power Derating for Hot Switching vs. Frequency, T
CASE
= 85°C
ESD CAUTION