FLM BK PB M12 DI 8 M12-EF
8008_en_00 PHOENIX CONTACT 4
Sensor Supply
Minimum sensor voltage U
S
-1 V
Nominal current per channel 600 mA
Nominal current per device 600 mA
Overload protection Electronic per device
Short-circuit protection Electronic per device
Error Messages to the Higher-Level Control or Computer System
Sensor supply short-circuit Yes
Sensor supply overload Yes
If an error is triggered by an overload or short circuit of the sensor supply, the device switches off the sensor supply of the channels and
updates the diagnostics. The corresponding error message can then be read out by the master. If the sensor supply U
S
is not sufficiently high,
the master can read out an appropriate error message also.
Interface
Bus system PROFIBUS DP
Incoming Bus
Coupling of shield connection Directly to FE
Transmission Speed 12 Mbaud, maximum
Outgoing Bus
Coupling of shield connection Directly to FE
Transmission Speed 12 Mbaud, maximum
For transmission rates of more than 3 MBaud in PROFIBUS, series inductance is available in the device. Please observe the installation
instructions of the PROFIBUS User Organization.
Electrical Isolation/Isolation of the Voltage Areas
Separate Potentials in the FLM BK PB M12 DI 8 M12-EF
- Test Distance - Test Voltage
24 V supply (bus logic) / FE 500 V AC, 50 Hz, 1 min
24 V supply (bus logic) / digital inputs (sensor supply/I/O) 500 V AC, 50 Hz, 1 min
24 V supply (bus logic) / incoming remote bus 500 V AC, 50 Hz, 1 min
Digital inputs (sensor supply/I/O) / FE 500 V AC, 50 Hz, 1 min
Digital inputs (sensor supply / I/O) / incoming remote bus 500 V AC, 50 Hz, 1 min
Incoming remote bus / FE 500 V AC, 50 Hz, 1 min
For device connection, please note the instructions and regulations in the "Installing the Fieldline Product Range" user manual
FLS FLM SYS INST UM E.
Approvals
For the latest approvals, please visit www.phoenixcontact.net/download.
FLM BK PB M12 DI 8 M12-EF
8008_en_00 PHOENIX CONTACT 5
4 Pin Assignment
Figure 2 Connections of the
FLM
BK PB M12 DI 8 M12-EF
B K P B
U
L S
I N
U S
O U T
I N
B U S
U L
B F
M D
L B
O U T
U
L S
I 1 I 2
R U N
I 3 I 4
I 5 I 6
I 7 I 8
2 M B D
B U S I N
B U S O U T
F E
L B O U T
U O U T
L S
I N 1 / I N 2
I N 3 / I N 4
I N 5 / I N 6
I N 7 / I N 8
7 0 0 8 A 0 0 2
U
L S
I N
0
2
4
6
9
8
0
2
4
6
8
1 2
1 0
1 0
x
1
x
Designation Meaning
FE Functional earth ground
BUS IN PROFIBUS IN
BUS OUT PROFIBUS OUT
LB OUT Local bus OUT (FLM local bus)
U
LS
IN Power supply IN
(logic and sensor supply)
U
LS
OUT Voltage supply OUT (logic and sensor
supply) for additional devices
IN1 to IN8 Inputs 1 to 8
ACHTUNG:
In general, the maximum current load of 4 A per
contact must not be exceeded.
FLM BK PB M12 DI 8 M12-EF
8008_en_00 PHOENIX CONTACT 6
4.1 Pin Assignment PROFIBUS
Figure 3 PROFIBUS pin assignment
(M12 B-encoded)
Mains termination resistors
Since PROFIBUS DP is a serial bus system in a linear or tree
structure, the individual branches must be terminated with a
termination resistor. The bus coupler does not have a
resistor of this type. For additional information, please refer
to the PROFIBUS documentation.
Phoenix Contact recommends using the PROFIBUS
connector SAC-5P-M12MS PB TR (Orden No. 1507803).
This connector has a termination resistor that can be
connected.
4.2 Local Bus Pin Assignment (LB OUT)
Figure 4 Local bus pin assignment (LB OUT)
Pin BUS IN BUS OUT
1 VP (Supply voltage
+ 5 V for
terminal resistor)
VP (Supply voltage
+ 5 V for
terminal resistor)
2 RxD/TxD-N (A) RxD/TxD-N (A)
3 GND VP GND VP
4 RxD/TxD-P (B) RxD/TxD-P (B)
5 Shield Shield
The shield is connected to FE in the device.
6 6 2 5 B 0 0 4
B U S I N
L B O U T
B U S O U T
Pin LB OUT
1 DO
2 DO
3 DI
4 DI
5 GND
The thread is used for shielding.
7 0 0 8 A 0 0 5
L B O U T

2773377

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
I/O Connectors FLM BK PB M12 DI 8 M12-EF
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet