ADCMP600/ADCMP601/ADCMP602
Rev. A | Page 6 of 16
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter Rating
Supply Voltages
Input Supply Voltage (V
CCI
to GND) −0.5 V to +6.0 V
Output Supply Voltage
(V
CCO
to GND)
−0.5 V to +6.0 V
Positive Supply Differential
(V
− V
)
−6.0 V to +6.0 V
Input Voltages
Input Voltage −0.5 V to V
CCI
+ 0.5 V
Differential Input Voltage ±(V
CCI
+ 0.5 V)
Maximum Input/Output Current ±50 mA
Shutdown Control Pin
Applied Voltage (HYS to GND) −0.5 V to V
CCO
+ 0.5 V
Maximum Input/Output Current ±50 mA
Latch/Hysteresis Control Pin
Applied Voltage (HYS to GND) −0.5 V to V
CCO
+ 0.5 V
Maximum Input/Output Current ±50 mA
Output Current ±50 mA
Temperature
Operating Temperature, Ambient −40°C to +125°C
Operating Temperature, Junction 150°C
Storage Temperature Range −65°C to +150°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
THERMAL RESISTANCE
θ
JA
is specified for the worst-case conditions, that is, a device
soldered in a circuit board for surface-mount packages.
Table 4. Thermal Resistance
Package Type θ
1
Unit
ADCMP600 SC70 5-Lead 426 °C/W
ADCMP600 SOT-23 5-Lead 302 °C/W
ADCMP601 SC70 6-Lead 426 °C/W
ADCMP602 MSOP 5-Lead 130 °C/W
1
Measurement in still air.
ESD CAUTION