GU128X64-800B
9
9.3 Cont’d
Brightness levels are set by the following:
BW3 BW2 BW1 BW0 Brightness Level
0 0 0 0 100%(Light)
0 0 0 1 94%
0 0 1 0 87%
0 0 1 1 81%
0 1 0 0 75%
0 1 0 1 69%
0 1 1 0 62%
0 1 1 1 56%
1 0 0 0 50%
1 0 0 1 44%
1 0 1 0 37%
1 0 1 1 31%
1 1 0 0 25%
1 1 0 1 19%
1 1 1 0 12%
1 1 1 1 6%(Dark)
9.4
Display Clear (C/D= "1") This command clears the GRAM.
This command should always be applied at power on or reset. In the period of 1mS following the
issue of this command, the module requires internal processing and does not accept any
commands.
MSB LSB
0 1 0 1 G1C G0C 1 HM
< --------------------------- > < ---------------------------- >
Command Select Clear Control Code
To clear the GRAM area, G1C or G0C bit must be asserted. By asserting HM bit, both data write position
address and display start position address which selected by G1C, G0C, DC also be reset.
HM = (1 or 0) equals (Initialize data write position address and display start position address or Not initialize).
G1C= (1 or 0) equals (GRAM area 1 is cleared or GRAM area 1 not cleared)
G0C= (1 or 0) equals (GRAM area 0 cleared or GRAM area 0 not cleared)
GRAM area 1: X= 00H-7FH, Y=0H – 7H (Display data write position address)
GRAM area 2: X= 00H-7FH, Y=8H – FH (Display data write position address)
GU128X64-800B
10
9.5 Display Area Set (C/D="1", only used for Initialize Set)
This command sets the display area block as Graphic Display (GRAM) or Character display
(DDRAM). But, this is version which has no Font ROM. Therefore, DDRAM is not available, all of
display area block must be assigned to GRAM as the initialize setting, and this must be done when
the module is powered up and also every time the reset is applied. Setup is performed by 3-byte
command.
1st Byte: (C/D="1") Command Select
MSB LSB
0 1 1 0 0 0 1 0
< ------------------------------------------------------------ >
Command Select
2nd Byte: (C/D="1") Display Area Data Address Select
MSB LSB
0 0 0 0 0 A2 A1 A0 (0H 7H)
< ------------------ >
Display Area Data Address
3rd Byte: (C/D="0") Display Area Block Select
MSB LSB
1 1 1 1 1 1 1 1
< ------------------------------------------------------------- >
Display Data
D0 to D7 = "1": Graphic Display (GRAM)
D0 to D7 = "0": Character Display (DDRAM, Not available)
Display area block is assigned as follows on a screen.
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
Dis
p
la
y
A
r
ea Data Add
r
ess
(
0to7H
)
0
12
345 6
7
8dot
16 dot
GU128X64-800B
11
9.6 GRAM Data Write position Address Set (Graphic Display) (C/D="1")
This command specifies both X & Y data write position address.
9.6.1 GRAM Data Write Position X Address Set
Data write position X address of GRAM expressed with 8 bits (00Hex-7FHex) is specified.
Refer to 8.1 Graphic Display (GRAM) on Page #5.
1st Byte: Command Select
MSB LSB
0 1 1 0 0 1 0 *
* Either a “0” or a “1” is acceptable
< ------------------------------------------------------------- >
2nd Byte:
GRAM Data Write Position X Address
MSB LSB
0 GXA6 GXA5 GXA4 GXA3 GXA2 GXA1 GXA0
< ------------------------------------------------------------- >
9.6.2 GRAM Data Write Position Y Address Set
Data write position Y address of GRAM expressed with 4 bits (0Hex-FHex) is specified.
1st Byte:
MSB LSB
0 1 1 0 0 0 0 *
* Either a “0” or a “1” is acceptable
< -------------------------------------------------------------- >
Command Select
2nd Byte:
MSB LSB
* * * * GYA3 GYA2 GYA1 GYA0 * Either a “0” or a “1” is acceptable
< -------------------------- >
9.7 GRAM Display Start Position Address Set (C/D="1")
9.7.1 Horizontal Shift
This command specifies the address that a display pattern can be positioned to by 8 bits (00Hex
to 7FHex). This is equivalent to an offset in the X-axis.
1st Byte:
MSB LSB
0 1 1 1 * * * *
* Either a “0” or a “1” is acceptable
< --------------------------- >
Command Select
2nd Byte:
MSB LSB
XA7 XA6 XA5 XA4 XA3 XA2 XA1 XA0
< -------------------------------------------------------------- >
GRAM Display Start Position Address
9.7.2 Vertical Shift
This is equivalent to an offset Y-axis.
MSB LSB
1 0 1 1 UD S1 S0 *
* Either a “0” or a “1” is acceptable
< --------------------------- > < ------------------ >
Command Select Display Shift Data
UD= "1": Display scrolled up.
UD= "0": Display scrolled down.
S1= "0", S0= "1": Display shift by 8 dots.
S1= "1", S0= "0": Display shift by 1 dot.
S1= "1", S0= "1": Display shift by 2 dots.