MAX13037/MAX13038
Automotive Contact Monitor and
Level Shifters with LDO Regulator
4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(BAT = +6V to +26V, T
A
= -40°C to +125°C, unless otherwise noted. Typical values are at BAT = +14V, T
A
= +25°C.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
LINEAR REGULATOR
MAX13037, V
BAT
= +14V, I
LOAD
= 1mA 4.92 5.00 5.08
Output Voltage V
LO
MAX13038, V
BAT
= +14V, I
LOAD
= 1mA 3.234 3.300 3.366
V
V
LO
= +5V
(MAX13037)
0.53 1
I
LOAD
= 1mA to 50mA,
V
BAT
= +14V
V
LO
= +3.3V
(MAX13038)
0.53 1
V
LO
= +5V
(MAX13037)
1 1.85
Load Regulation LOAD _REG
I
LOAD
= 1mA to 150mA,
V
BAT
= +14V
V
LO
= +3.3V
(MAX13038)
1 1.85
%
Line Regulation LINE_REG V
BAT
= +6V to +26V -0.9 +0.9 mV/V
V
LO
= +5V, I
LO
= 50mA (MAX13037) 330
V
LO
= +5V, I
LO
= 150mA (MAX13037) 1000Dropout Voltage V
DROP
V
LO
= +3.3V, I
LO
= 150mA (MAX13038) 1300
mV
Output Current Limit I
LIM
V
BAT
= +14V 150 mA
Power-Supply Rejection Ratio PSRR
I
LO
= 10mA, f = 100Hz, 500mV
P-P
,
AC-coupled into V
BAT
68 dB
Start-Up Time t
START
1ms
RESET, WATCHDOG
Reset Reference Voltage V
RST
THRESH from high to low 1.20 1.24 1.28 V
THERMAL SHUTDOWN
Thermal Shutdown Temperature T
SHDN
(Note 6) 165 °C
Thermal Shutdown Temperature
for Wetting Currents Only
T
WARN
(Note 7) 135 °C
Thermal Shutdown Hysteresis T
HYST
15 °C
TIMING CHARACTERISTICS
(BAT = +6V to +26V, T
A
= -40°C to +125°C, unless otherwise noted. Typical values are at BAT = +14V, T
A
= +25°C.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
V
BAT
= +6V 22 35
IN0 to DO0 Propagation Delay,
IN1 to DO1 Propagation Delay
t
PROP
V
BAT
= +14V 22
µs
CLK Frequency f
CLK
Input rise/fall time < 2ns 5 MHz
Falling Edge of CS to Rising
Edge of CLK
Required Setup Time
t
LEAD
Input rise/fall time < 2ns, Figure 1 110 ns
Falling Edge of CLK to Rising
Edge of CS
Required Setup Time
t
LAG
Input rise/fall time < 2ns, Figure 1 50 ns
MAX13037/MAX13038
Automotive Contact Monitor and
Level Shifters with LDO Regulator
_______________________________________________________________________________________ 5
TIMING CHARACTERISTICS (continued)
(BAT = +6V to +26V, T
A
= -40°C to +125°C, unless otherwise noted. Typical values are at BAT = +14V, T
A
= +25°C.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SDI to Falling Edge of CLK
Required Setup Time
t
SI(SU)
Input rise/fall time < 2ns, Figure 1 30 ns
Falling Edge of CLK to SDI
Required Hold Time
t
SI
(
HOLD
)
Input rise/fall time < 2ns, Figure 1 20 ns
Time from Falling Edge of CS to
SDO Low Impedance
t
SO(EN)
Input rise/fall time < 2ns, Figure 1 55 ns
Time from Rising Edge of CS to
SDO High Impedance
t
SO
(
DIS
)
Figures 1 and 2 55 ns
Time from Rising Edge of CLK to
SDO Data Valid
t
VALID
C
SDO
=15pF, Figure 1 70 ms
C
TDEB
= 500pF 3.18 5.9 9.42 ms
Debounce Time t
DEB
C
TDEB
= 10nF 63 120 188 ms
Scanning Time Pulse t
SCAN
130 250 400 µs
Scanning Time Period t
SCAN-P
SC0 = 0, SC1 = 1, SC2 = 1 4 8 14 ms
Wetting Time Pulse t
WETT
WTOFF = 0 10 21 35 ms
Time from Shutdown to Normal
Operation
t
SD
SD low-to-high transition to input monitoring
enabled
200 µs
Time from SCAN Mode to Normal
Operation
t
SM
(Note 8) 500 µs
Reset Output Pulse Width t
RST
C
TD
= 10nF (Figure 3) 10 21 36 ms
Watchdog Timeout Period 1 t
WD1
C
TD
= 10nF, time before INT goes low
(Figure 3)
40 84 144 ms
Watchdog Timeout Period 2 t
WD2
C
TD
= 10nF, time before RST goes low
(Figure 3)
2 x t
WD1
ms
Minimum Watchdog Timeout
Reset on WDI
t
WDI
300 ns
Note 2: All units are 100% production tested at T
A
= 125°C. Limits over the operating temperature range are guaranteed by design and
not production tested.
Note 3: V
TH_C
= (V
TH_HIGH
+ V
TH_LOW
) / 2.
Note 4: V
TH_HYS
= (V
TH_HIGH
- V
TH_LOW
).
Note 5: Wetting current rise/fall time is measured as the time it takes to go from 20% to 80% of the maximum wetting current.
Note 6: T
SHDN
is the temperature at which the wetting currents and LDO are disabled.
Note 7: T
WARN
is the temperature at which only the wetting currents are disabled.
Note 8: When exiting SCAN mode to enter Normal Mode (through SPI) any input change is ignored for 500µs (typ) to allow correct
wake-up of input comparators. After this time elapses, the inputs are monitored in continuous mode.
MAX13037/MAX13038
Automotive Contact Monitor and
Level Shifters with LDO Regulator
6 _______________________________________________________________________________________
CS
CLK
SDI MSB IN
MSB OUT LSB OUT
t
SO(DIS)
t
VALID
t
SO(EN)
t
LEAD
SDO
t
LAG
t
SI(SU)
t
SI(HOLD)
Figure 1. SPI Timing Characteristics
MAX13037/
MAX13038
CS
SDO
SDOCS
15pF
1/3V
L
1kΩ
t
SO(EN)
V
L
t
SO(DIS)
V
OL
+ 0.1V
L
Figure 2. SDO Enable/Disable Test Circuit and Timing Diagram
WDI
INT
RST
NORMAL OPERATION
(NO SWITCHES ACTIVE)
t
WD1
t
WD1
t
WD2
t
RST
Figure 3. Watchdog Interrupt/Reset Timing Diagram

MAX13038ATI+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Interface - Specialized Auto Contact Monitor & Level Shift w/LDO
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet