MCR-C-UI-UI-DCI
100238_de_06 PHOENIX CONTACT 7
9 Installation
A
B
B
1
B
2
The assignment of the connection terminal blocks is shown in
the block diagram. The module can be snapped onto all 35
mm DIN rails according to EN 60715.
Assembly
Position the module with the DIN rail guide on the upper edge
of the DIN rail, and snap it in with a downward motion.
Removing
Pull the snap lever open with the aid of a screwdriver and slide
the module out at the lower edge of the DIN rail.
WARNING:
In potentially explosive areas, snap the module
onto the DIN rail and connect the cables only
when the power is disconnected.
123
MCR -C -UI/UI -DCI
Art.-Nr.:281091
1
2
3
7
8
9
10
11
12
IN U/I
GND 1
OUT I
GND 2
+24VDC
GND 3
GND 3
APPROBATIONEN /
GND 1
OUT U
POWER
OUT
IN
MCR-C-UI-UI-DCI
POWER
SPAN
ZERO
U/I GND1 GND1
I U GND2
+24V GND3 GND3
A
B
Screw Connection
Insert the wires in the corresponding connection terminal
block.
Use a screwdriver to tighten the screw in the opening above
the connection terminal block.
MCR-C-UI-UI-DCI
100238_de_06 PHOENIX CONTACT 8
10 Configuration
HYBRID TV1
PHOENIX CONTACT
DIP 1
DIP 2
If the modules are not configured (all DIP switches set to
pos.0), the module does not have a defined function until the
DIP switches have been set.
DIP switches S1 and S2 specify the combination of input and
output standard signal ranges (see configuration table).
Standard Configuration
"NC" versions (...-NC) have the following standard configura-
tion:
0 ... 10 V input
0 ... 10 V output
(All DIP switches are set to the "OFF" position)
Opening the Module
Using a screwdriver, release the locked upper housing part
on both sides. The upper housing part and the electronics can
now be pulled out approximately 3 cm.
CAUTION: Electrostatic discharge
The module contains components that can be
damaged or destroyed by electrostatic dischar-
ge. When handling the module, observe the
necessary safety precautions against elec-
trostatic discharge (ESD) according to
EN61340-5-1 and IEC61340-5-1.
11 Adjustment
The "ZERO" potentiometer is used to adjust the zero point of
the module and the "SPAN" potentiometer is used to adjust
the final value. Both potentiometers are located on the top of
the module.
NOTE: Module can become damaged
Before commencing the adjustment process,
observe the warm-up phase of two minutes.
MCR-C-UI-UI-DCI
100238_de_06 PHOENIX CONTACT 9
12 DIP switches
X = ON Input 0 ... 5 V Output 0 ... 10 V Output ±5 V Output ±10 V Output
DIP 1 DIP 2 DIP 2 DIP 2 DIP 2
Input 12345678 12345678910 12345678910 12345678910 12345678910
0 ... 60 mV X XXX X X X XX X X XXX X X X XXX
0 ... 100 mV X X X X X X X X X X X X X X X X X X
0 ... 200 mV X X X X X X X X X X X X X X X X X X
0 ... 300 mV X X X X X X X X X X X X X X X X X X X
0 ... 500 mV X X X X X X X X X X X X X X X X X X
0 ... 1 V X X X X X XX X X XXX X X X XXX
0 ... 2 V X X X X X XX X X XXX X X X XXX
0 ... 2.5 V X X X X X X X X X X X X X X X X X
0 ... 5 V X X X X XX X X XXX X X X XXX
0 ... 10 V X X X X XX X X XXX X X X XXX
0 ... 20 V X X X X XX X X XXX X X X XXX
±60 mV X XXX X X X X XX X X X X XX
±100 mV X X X X X X XX X X X X XX
±200 mV X X X X X X XX X X X X XX
±300 mV XXXXXX XXXX XX XXX
±500 mV X X X X X X XX X X X X XX
±1 V X X X X X XXXX X X XXX
±2 V XX XX X XXXX X X XXX
±2.5 V X X X X X XX X X X X XX
±5 V X X X X X XX X X X X XX
±10 V X X X X X XX X X X X XX
±20 V X X X X X XX X X X X XX
0 ... 5 mA X X XXX X X X XX X X XXX X X X XXX
0 ... 10 mA XX X X X X XX X X XXX X X X XXX
0 ... 20 mA X X X X X X XX X X XXX X X X XXX
±5 mA X X XXX X X X X XX X X X X XX
±10 mA XX X XX X XXXX X X XXX
±20 mA XX X XX X XXXX X X XXX
1 ... 5 V X X X X X X X X X X X
4 ... 20 mA X X X X X X X X X X X X X
X = ON 1 ... 5 V Output 0 ... 5 mA Output 0 ... 10 mA Output 0 ... 20 mA Output 4 ... 20 mA Output
DIP 2DIP 2DIP 2DIP 2DIP 2
Input 12345678910 12345678910 12345678910 12345678910 12345678910
0 ... 60 mV X X X X X X X X X X X X X
0 ... 100 mV X X X X X X X X X X X X X
0 ... 200 mV X X X X X X X X X X X X X
0 ... 300 mV X X X X X X X X X X X X X
0 ... 500 mV X X X X X X X X X X X X X
0 ... 1 V X X X X X X X X X X X X X
0 ... 2 V X X X X X X X X X X X X X
0 ... 2.5 V X X X X X X X X X X X X X
0 ... 5 V X X X X X X X X X X X X X
0 ... 10 V X X X X X X X X X X X X X
0 ... 20 V X X X X X X X X X X X X X
±60 mV X X X X X X X
±100 mV X X X X X X X
±200 mV X X X X X X X
±300 mV X X X X X X X
±500 mV X X X X X X X
±1 V XX X XXXX
±2 V XX X XXXX
±2.5 V XX X XXXX
±5 V XX X XXXX
±10 V XX X XXXX
±20 V XX X XXXX
0 ... 5 mA X X X X X X X X X X X X X
0 ... 10 mA X X X X X X X X X X X X X
0 ... 20 mA X X X X X X X X X X X X X
±5 mA X X X X X X X
±10 mA X X X X X X X
±20 mA X X X X X X X
1 ... 5 V X X X X X X X X
4 ... 20 mA X X X X X X X X
±5 V Output ±10 V Output 1 ... 5 V Output 0 ... 20 mA Output 4 ... 20 mA Output
Constant 10 V 20 V 4 V 18 mA 16 mA
Output final value 5V 10V 5V 20mA 20mA
Adjustment tolerance ±0.5 mV ±0.5 mV ±1 mV ±1 μ1 μA

2810887

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules Signal conditioner MCR-C-UI-UI-450-DCI