Philips Semiconductors Product data
PCA9510; PCA9511
Hot swappable I
2
C and
SMBus bus buffer
2003 Dec 18
13
SYMBOL UNIT
LIMITS
TEST CONDITIONSPARAMETER
SYMBOL UNIT
MAX.TYP.MIN.
TEST CONDITIONSPARAMETER
System characteristics
f
I2C
I
2
C operating frequency 0 — 400 kHz
t
BUF
Bus free time between stop and
start condition
Note 4 1.3 — — µs
t
hD,STA
Hold time after (repeated) start
condition
Note 4 0.6 — — µs
t
su,STA
Repeated start condition setup time Note 4 0.6 — — µs
t
su,STO
Stop condition setup time Note 4 0.6 — — µs
t
hD,DAT
Data hold time Note 4 300 — — µs
t
su,DAT
Data setup time Note 4 100 — — µs
t
LOW
Clock low period Note 4 1.3 — — µs
t
HIGH
Clock high period Note 4 0.6 — — µs
t
t
Clock, data fall time Notes 4 and 5 20 +0.1 x C
B
— 300 ns
t
r
Clock, data rise time Notes 4 and 5 20 +0.1 x C
B
— 300 ns
NOTES:
1. This specification applies over the full operating temperature range.
2. I
PULLUPAC
varies with temperature and V
CC
voltage, as shown in the Typical Performance Characteristics section.
3. The connection circuitry always regulates its output to a higher voltage than its input. The magnitude of this offset voltage as a function of the
pull-up resistor and V
CC
voltage is shown in the Typical Performance Characteristics section.
4. Guaranteed by design, not production tested.
5. C
B
= total capacitance of one bus line in pF.
6. SDA_IN/SCL_IN = 0.1 V, SDA_OUT/SCL_OUT through resistor to V
CC
.
7. Delays that can occur after ENABLE and/or idle times have passed.