209
PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
• Type K Foot Mount - features a steel bracket welded to the bottom of the
laminations for easy mounting.
• Type G Panel Mount - features .218” (5.54 mm) diameter holes in each
corner to allow direct mounting to a panel.
• For agency approval, 60 & 75VA transformers must have one of the
following overcurrent protectors in series with the secondary winding:
Internal fuse, integral circuit breaker. Any customer-supplied fusing or
protection must be approved by the factory.
• Multiple voltage combinations are available. Consult factory for availability.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Wire Size: All leads are 18 AWG stranded 2/64” (.794 mm) insulation
thickness. Standard parts have 12” (305 mm) total length with
1/2” (12.7 mm) strip.
Frequency: 50/60 Hz.
Insulation Class: UL Class B (130°C).
Weight: 60VA – 35.2 oz. (997 g); 75VA – 38.4 oz. (1087 g).
4000 series
Class II UL 1585 Transformer
60VA -75VA Non-Inherently Energy Limited
Secondary Fusing Required
Wire Leads
File E87824
Outline Dimensions
Standard “999” Models Available
Partial Listing of Custom Models
* A three digit customer ID suffix will be assigned by the factory.
For Type G Panel Mount, replace K in above part numbers with G.
For more details about standard models see Part Numbering System table at
beginning of transformer section in this catalog . All 75VA standard models
come with an integral circuit breaker.
.187 DIA
(4.75)
3.562 (90.47)
A” DIM.
.062
(1.57)
.22
(5.59)
.750
(19.05)
“B” DIM.
A” DIM.
L15K & J15K L15K & J15K J41K
Internally Fused w/ Integral Circuit Breaker Standard Part
A” Dimension [inches (mm)] 2.475 (62.86) 3.25 (82.55) 3.45 (87.63)
“B” Dimension [inches (mm)] 1.00 (25.4) 1.00 (25.4) 1.125 (28.58)
Type K
Foot Mount -
Internally
Fused
A” and “B” Dimensions for 60VA & 75VA Models
3.00 (76.2)
2.106 (53.49)
.830
(21.1)
“B” DIM.
A” DIM.
2.50
(63.5)
“B” DIM.
Primary V Secondary V 60VA 75VA
120 24 4000-01L15K* 4000-01J15K*
240 24 4000-02L15K* 4000-02J15K*
277 24 4000-03L15K* 4000-03J15K*
480 24 4000-04L15K* 4000-04J15K*
120/208/240 24 4000-05L15K* 4000-05J15K*
208/240 24 4000-09L15K* 4000-09J15K*
208/240/480 24 4000-13J15K*
380/415 24 4000-51J15K*
575 24 4000-78J15K*
1.830
(46.48)
1.830
(46.48)
3.00 (76.2)
2.50
(63.5)
Type K
Foot Mount -
Integral
Circuit
Breaker
1.830
(46.48)
.218 DIA
(5.54)
2.0
(50.8)
.218 (5.54)
2.50 (63.5)
Primary V Secondary V 75VA
120 24 4000-01J15K999
277 24 4000-03J15K999
208/240 24 4000-09J15K999
575 24 4000-78J15K999
120/208/240/480 24 4000-08J15K999
SEE TABLE
2.106 (53.49)
3.562 (90.47)
.22
(5.59)
.187 DIA
(4.75)
.750
(19.05)
.062
(1.57)
SEE TABLE
SEE TABLE
2.106 (53.49)
Type G
Panel Mount
Primary Leads Secondary Leads
Voltage COM 120 208 240 277 480 575 24 VAC
Color Black White Red Orange Brown Black/Red Gray Blue Yellow
Length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305)
Strip Length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7)
Details regarding leads on standard models
210
PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
• Type BB Same Side Termination - features quick connect terminals with
line and load terminations on the same side of transformer.
• Type AE Laydown Termination - features quick connect terminals with line
and load terminations on the top of transformer.
• For agency approval, 60 & 75VA transformers must have one of the
following overcurrent protectors in series with the secondary winding:
Internal fuse, integral circuit breaker. Any customer-supplied fusing or
protection must be approved by the factory.
• Multiple voltage combinations are available. Consult factory for availability.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Terminals: Standard male quick connects are .250” x .032” (6.35 x .81
mm). Other available quick connects include .187” x .032”
(4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm).
Frequency: 50/60 Hz.
Insulation Class: UL Class B (130°C).
Weight: 60VA – 35.2 oz. (997 g); 75VA – 38.4 oz. (1087 g).
4000
series
Class II UL 1585 Transformer
60VA -75VA Non-Inherently Energy Limited
Secondary Fusing Required
Quick Connect Terminals
File E87824
Outline Dimensions
Primary V Secondary V 75VA
120 24 4000-01J15AE999
208/240 24 4000-09J15AE999
Standard “999” Models Available
Partial Listing of Custom Models
* A three digit customer ID suffix will be assigned by the factory.
For Type AE Laydown Termination, replace BB in above part numbers with AE.
For more details about standard models see Part Numbering System table at
beginning of transformer section in this catalog. All 75VA standard models come
with an integral circuit breaker.
.187 DIA
(4.75)
3.562 (90.47)
A” DIM.
.062
(1.57)
.22
(5.59)
.750
(19.05)
“B” DIM.
A” DIM.
.187 DIA
(4.75)
Internally Fused w/ Integral Circuit Breaker
A” Dimension [inches (mm)] 2.475 (62.86) 3.25 (82.55)
“B” Dimension [inches (mm)] 1.00 (25.4) 1.00 (25.4)
Type BB
Same Side
Termination
Type AE
Laydown
Termination -
Internally Fused
A” and “B” Dimensions for 60VA & 75VA Models
3.00
(76.2)
2.10 (53.34)
.830
(21.1)
“B” DIM.
A” DIM.
2.50
(63.5)
“B” DIM.
1. 0
(2.54)
R .375
(9.53)
Primary V Secondary V 60VA 75VA
120 24 4000-01L15BB* 4000-01J15BB*
240 24 4000-02L15BB* 4000-02J15BB*
277 24 4000-03L15BB* 4000-03J15BB*
480 24 4000-04L15BB* 4000-04J15BB*
120/208/240 24 4000-05L15BB* 4000-05J15BB*
208/240 24 4000-09L15BB* 4000-09J15BB*
208/240/480 24 4000-13J15BB*
380/415 24 4000-51J15BB*
575 24 4000-78J15BB*
R .375
(9.53)
1.830
(46.48)
2.40 (61.0)
.062 (1.57)
1.830
(46.48)
3.562 (90.47)
3.00 (76.2)
.219
(5.56)
2.50
(63.5)
2.10 (53.34)
Type AE
Laydown
Termination -
Integral
Circuit
Breaker
1.830
(46.48)
.830
(21.1)
.062 (1.57)
.187 DIA
(4.75)
1. 0
(2.54)
R .375
(9.53)
3.562 (90.47)
3.00 (76.2)
.219
(5.56)
2.50
(63.5)
2.40 (61.0)
211
PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03 (PDF Rev. 4-04)
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
• Type K Foot Mount - features wire leads and a steel bracket welded to
the bottom of the laminations for easy mounting.
• Type BB Same Side Termination - features quick connect terminals with
line and load terminations on the same side of transformer.
• Multiple voltage combinations are available. Consult factory for availability.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Wire Size: All leads are 18 AWG stranded 2/64” (.794 mm) insulation
thickness. Standard parts have 12” (305 mm) total length with
1/2” (12.7 mm) strip.
Terminals: Standard male quick connects are .250” x .032” (6.35 x .81
mm). Other available quick connects include .187” x .032”
(4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm).
Frequency: 50/60 Hz.
Insulation Class: UL Class B (130°C).
Weight: 60VA – 36.8 oz. (1042 g); 100VA – 80 oz. (2270 g);
150VA – 83.2 oz. (2356 g).
4700 series
UL 506 Transformer
60VA - 150VA Non-Fused
Wire Leads or
Quick Connects
File E102980
Outline Dimensions
Primary Leads Secondary Leads
Voltage COM 120 208 240 277 480 575 24 VAC
Color Black White Red Orange Brown Black/Red Gray Blue Yellow
Length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305)
Strip Length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7)
Primary V Secondary V 60VA 100VA
120 24 4700-81L15K999
120/208/240/480 24 4700-08K18K999
Primary V Secondary V 100VA 150VA
120 24 4700-01K18K* 4700-01Z18K*
277 24 4700-03K18K* 4700-03Z18K*
480 24 4700-04K18K* 4700-04Z18K*
120/208/240/480 24 4700-08K18K*
208/240 24 4700-09K18K* 4700-09Z18K*
208/230/460 24 4700-12K18K*
208/240/480 24 4700-13K18K*
400 24 4700-48K18K* 4700-48Z18K*
575 24 4700-78K18K* 4700-78Z18K*
460/575 24 4700-130K18K* 4700-130Z18K*
Standard “999” Models Available
Partial Listing of Custom Models
* A three digit customer ID suffix will be assigned by the factory.
For more details about standard models see Part Numbering System table at
beginning of transformer section in this catalog .
.187 DIA
(4.75)
SEE TABLE
.22
(5.59)
.750
(19.05)
Type K
Foot Mount
60VA
3.562
(90.47)
.062
(1.57)
3.00
(76.2)
2.106 (53.49)
2.50
(63.5)
2.475
(62.87)
Type K
Foot Mount
100VA
1.830
(46.48)
SEE TABLE
1. 0 0
(25.4)
.187 X R. 375
(4.75 x 9.52)
2.313
(58.75)
3.125 (79.38)
2.53 (64.26)
3.125
(79.38)
3.75
(95.25)
2.165
(54.99)
1.25
(31.75)
2.875
(73.03)
.075
(1.91)

4700-26EW30BB999

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Power Transformers TRANSFORMER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union