209
PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
• Type K Foot Mount - features a steel bracket welded to the bottom of the
laminations for easy mounting.
• Type G Panel Mount - features .218” (5.54 mm) diameter holes in each
corner to allow direct mounting to a panel.
• For agency approval, 60 & 75VA transformers must have one of the
following overcurrent protectors in series with the secondary winding:
Internal fuse, integral circuit breaker. Any customer-supplied fusing or
protection must be approved by the factory.
• Multiple voltage combinations are available. Consult factory for availability.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Wire Size: All leads are 18 AWG stranded 2/64” (.794 mm) insulation
thickness. Standard parts have 12” (305 mm) total length with
1/2” (12.7 mm) strip.
Frequency: 50/60 Hz.
Insulation Class: UL Class B (130°C).
Weight: 60VA – 35.2 oz. (997 g); 75VA – 38.4 oz. (1087 g).
4000 series
Class II UL 1585 Transformer
60VA -75VA Non-Inherently Energy Limited
Secondary Fusing Required
Wire Leads
File E87824
Outline Dimensions
Standard “999” Models Available
Partial Listing of Custom Models
* A three digit customer ID suffix will be assigned by the factory.
For Type G Panel Mount, replace K in above part numbers with G.
For more details about standard models see Part Numbering System table at
beginning of transformer section in this catalog . All 75VA standard models
come with an integral circuit breaker.
.187 DIA
(4.75)
3.562 (90.47)
“A” DIM.
.062
(1.57)
.22
(5.59)
.750
(19.05)
“B” DIM.
“A” DIM.
L15K & J15K L15K & J15K J41K
Internally Fused w/ Integral Circuit Breaker Standard Part
“A” Dimension [inches (mm)] 2.475 (62.86) 3.25 (82.55) 3.45 (87.63)
“B” Dimension [inches (mm)] 1.00 (25.4) 1.00 (25.4) 1.125 (28.58)
Type K
Foot Mount -
Internally
Fused
“A” and “B” Dimensions for 60VA & 75VA Models
3.00 (76.2)
2.106 (53.49)
.830
(21.1)
“B” DIM.
“A” DIM.
2.50
(63.5)
“B” DIM.
Primary V Secondary V 60VA 75VA
120 24 4000-01L15K* 4000-01J15K*
240 24 4000-02L15K* 4000-02J15K*
277 24 4000-03L15K* 4000-03J15K*
480 24 4000-04L15K* 4000-04J15K*
120/208/240 24 4000-05L15K* 4000-05J15K*
208/240 24 4000-09L15K* 4000-09J15K*
208/240/480 24 – 4000-13J15K*
380/415 24 – 4000-51J15K*
575 24 – 4000-78J15K*
1.830
(46.48)
1.830
(46.48)
3.00 (76.2)
2.50
(63.5)
Type K
Foot Mount -
Integral
Circuit
Breaker
1.830
(46.48)
.218 DIA
(5.54)
2.0
(50.8)
.218 (5.54)
2.50 (63.5)
Primary V Secondary V 75VA
120 24 4000-01J15K999
277 24 4000-03J15K999
208/240 24 4000-09J15K999
575 24 4000-78J15K999
120/208/240/480 24 4000-08J15K999
SEE TABLE
2.106 (53.49)
3.562 (90.47)
.22
(5.59)
.187 DIA
(4.75)
.750
(19.05)
.062
(1.57)
SEE TABLE
SEE TABLE
2.106 (53.49)
Type G
Panel Mount
Primary Leads Secondary Leads
Voltage COM 120 208 240 277 480 575 24 VAC
Color Black White Red Orange Brown Black/Red Gray Blue Yellow
Length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305)
Strip Length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7)
Details regarding leads on standard models