206
PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
• Type BC Plate Mount - mounted on a 4” (101.6mm) square plate designed
to fit a standard 4” (101.6mm) square electrical box.
• The line voltage is connected inside the electrical boxto the color-coded
leads on the transformer. The low voltage is terminated to either 1/4”
(4.75 mm) quick connects and/or #6-32 screw furnished on the
secondary side.
• Multiple voltage combinations are available. Consult factory for availability.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Wire Size: All leads are 18 AWG stranded 2/64” (.794 mm) insulation
thickness. Standard parts have 12” (305 mm) total length with
1/2” (12.7 mm) strip.
Frequency: 50/60 Hz.
Insulation Class: UL Class B (130°C).
Weight: 20VA – 19.2 oz. (544 g); 40VA – 32 oz. (906 g).
4000 series
Class II UL 1585 Transformer
20VA - 40VA Inherently Energy Limited
No Secondary Fusing Required
Plate for Electrical Box Mounting
File E87824
Outline Dimensions
1.55
(39.37)
3.375
(85.72)
1.88
(47.75)
A” DIM.
.22
(5.59)
2.25
(57.15)
1.25
(31.75)
1.1 8 7
(30.15)
1. 0 0
(25.4)
“B” DIM.
.50
(12.7)
Primary Leads Secondary Leads
Voltage COM 120 208 240 277 480 575 24 VAC
Color Black White Red Orange Brown Black/Red Gray Blue Yellow
Length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305)
Strip Length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7)
Details regarding leads on standard models
Primary V Secondary V 20VA 40VA
120 24 4000-01C02BC999 4000-01V18BC999
Primary V Secondary V 20VA 40VA
120 24 4000-01C02BC* 4000-01V18BC*
208/240 24 4000-09C02BC* 4000-09V18BC*
Standard “999” Models Available Partial Listing of Custom Models
* A three digit customer ID suffix will be assigned by the factory.
All custom model part numbers are listed as Type K Foot Mount. To
specify Type G Panel Mount, replace K in above part numbers with G.
For more details about standard models see Part Numbering System table
at beginning of transformer section in this catalog .
.187
(4.75)
.187
(4.75)
3.375
(85.72)
4.25
(108)
4.25
(108)
20 VA 40 VA
A” Dimension [inches (mm)] 1.625 (41.28) 2.56 (65.02)
“B” Dimension [inches (mm)] .625 (15.88) 1.25 (31.75)
A” and “B” Dimensions
207
PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
• Type K Foot Mount - features a steel bracket welded to the bottom of the
laminations for easy mounting.
• Type G Panel Mount - features .156” (3.96 mm) diameter holes in each
corner to allow direct mounting to a panel.
• Multiple voltage combinations are available. Consult factory for availability.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Wire Size: All leads are 18 AWG stranded 2/64” (.794 mm) insulation
thickness. Standard parts have 12” (305 mm) total length with
1/2” (12.7 mm) strip.
Frequency: 50/60 Hz.
Insulation Class: UL Class B (130°C).
Weight: 40VA – 24.3 oz. (600 g); 50VA – 33.6 oz. (953 g).
4000 series
Class II UL 1585 Transformer
40 VA - 50VA Inherently Energy Limited
No Secondary Fusing Required
Wire Leads
File E87824
Outline Dimensions
Primary Leads Secondary Leads
Voltage COM 120 208 240 277 480 575 24 VAC
Color Black White Red Orange Brown Black/Red Gray Blue Yellow
Length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305)
Strip Length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7)
Details regarding leads on standard models
Primary V Secondary V 40VA 50VA
120 24 4000-01E07K999 4000-01AW18K999
277 24 4000-03E07K999 4000-03AW18K999
480 24 4000-04E07K999 4000-04AW18K999
120/208/240 24 4000-05E07K999
208/240 24 4000-09E07K999 4000-09AW18K999
Primary V Secondary V 40VA 40VA 50VA
120 24 4000-01V18K* 4000-01E07K* 4000-01AW18K*
240 24 4000-02V18K* 4000-02E07K* 4000-02AW18K*
277 24 4000-03V18K* 4000-03E07K* 4000-03AW18K*
480 24 4000-04V18K* 4000-04E07K* 4000-04AW18K*
120/208/240 24 4000-05E07K*
208/240 24 4000-09V18K* 4000-09E07K* 4000-09AW18K*
208/240/480 24 4000-13E07K*
380/415 24 4000-51V18K* 4000-51E07K* 4000-51AW18K*
575 24 4000-78V18K* 4000-78E07K* 4000-78AW18K*
Standard “999” Models Available Partial Listing of Custom Models
* A three digit customer ID suffix will be assigned by the factory.
All custom model part numbers are listed as Type K Foot Mount. To specify Type G Panel
Mount, replace K in above part numbers with G.
For more details about standard models see Part Numbering System
table at beginning of transformer section in this catalog .
[1] 1.55 (39.37)
[2] 1.813 (46.05)
.187 DIA
(4.75)
[1] 2.812 (71.42)
[2] 3.125 (79.38)
SEE TABLE
A” DIM.
03
(.76)
.22
(5.59)
.750
(19.05)
[1] 1.25 (31.75)
[2] 1.44 (36.58)
“B” DIM.
A” DIM.
SEE
TABLE
.218
(5.54)
.156 DIA TYP
(3.96)
[1] 1.50 (38.1)
[2] 1.75 (44.45)
40 VA / V18 40 VA / E07 50 VA / AW18
A” Dimension [inches (mm)] 2.25 (57.15) 2.125 (53.98) 2.56 (65.02)
“B” Dimension [inches (mm)] 1.25 (31.75) 0.875 (22.22) 1.25 (31.75)
Type K
Foot Mount
Type G
Panel Mount
A” and “B” Dimensions
[1] 2.25 (57.15)
[2] 2.625 (66.68)
[1] 1.88 (47.75)
[2] 2.188 (55.58)
[1] 1.55 (39.37)
[2] 1.813 (46.05)
[1] 1.88 (47.75)
[2] 2.188 (55.58)
[1] 1.25 (31.75)
[2] 1.44 (36.58)
[1] Applies to V18 models.
[2] Applies to E07 & AW18 models.
208
PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
• Type BB Same Side Termination - features quick connect terminals with
line and load terminations on the same side of transformer.
• Type AE Laydown Termination - features quick connect terminals with line
and load terminations on the top of transformer.
• Type AB Opposite Side Termination - features quick connect terminals
with line and load terminations on opposite sides of transformer.
• Multiple voltage combinations are available. Consult factory for availability.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Terminals: Standard male quick connects are .250” x .032” (6.35 x .81
mm). Other available quick connects include .187” x .032”
(4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm).
Frequency: 50/60 Hz.
Insulation Class: UL Class B (130°C).
Weight: 40VA – 22.4 oz. (636 g); 50VA – 35.2 oz. (999 g).
4000 series
Class II UL 1585 Transformer
40VA - 50VA Inherently Energy Limited
No Secondary Fusing Required
Quick Connect Terminals
File E87824
Outline Dimensions
Primary V Secondary V 40VA
120 24 4000-01E07AE999
120 24 4000-01E07BB999
208/240 24 4000-09E07AE999
Primary V Secondary V 40VA 40VA 40VA 50VA
120 24 4000-01E07BB* 4000-01V18BB* 4000-01V18AB* 4000-01AW18BB*
240 24 4000-02E07BB* 4000-02V18BB* 4000-02V18AB* 4000-02AW18BB*
277 24 4000-03E07BB* 4000-03V18BB* 4000-03V18AB* 4000-03AW18BB*
480 24 4000-04E07BB* 4000-04V18BB* 4000-04V18AB* 4000-04AW18BB*
208/240 24 4000-09E07BB* 4000-09V18BB* 4000-09V18AB* 4000-09AW18BB*
380/415 24 4000-51E07BB* 4000-51V18BB* 4000-51V18AB* 4000-51AW18BB*
575 24 4000-78E07BB* 4000-78V18BB* 4000-78AW18BB*
Standard “999” Models Available Partial Listing of Custom Models
* A three digit customer ID suffix will be assigned by the factory.
To specify Type AE Laydown Termination, replace BB in above part numbers with AE.
For more details about standard models see Part
Numbering System table at beginning of
transformer section in this catalog .
.187 DIA
(4.75)
[1] 2.25 (57.15)
[2] 3.125 (79.38)
A” DIM.
.031
(.787)
.22
(5.59)
.750
(19.05)
“B” DIM.
A” DIM.
.187 DIA
(4.75)
[1] 2.812 (71.42)
[2] 3.125 (79.38)
40 VA / V18 40 VA / E07 50 VA / AW18
A” Dimension [inches (mm)] 2.25 (57.15) 2.125 (53.98) 2.56 (65.02)
“B” Dimension [inches (mm)] 1.25 (31.75) 0.875 (22.22) 1.25 (31.75)
Type BB
Same Side
Termination
Type AE
Laydown
Termination
A” and “B” Dimensions
[1] 2.25 (57.15)
[2] 2.625 (66.68)
[1] 1.50 (38.1)
[2] 1.81 (45.97)
[1] 1.40 (35.56)
[2] 1.494 (37.95)
[1] Applies to V18 models.
[2] Applies to E07 & AW18 models.
“B” DIM.
A” DIM.
Type AB
Opposite Side
Termination
[1] 1.88 (47.75)
[2] 2.188 (55.58)
[1] 1.88 (47.75)
[2] 2.188 (55.58)
“B” DIM.
[1] 1.40 (35.56)
[2] 1.494 (37.95)
1. 0
(2.54)
R .375
(9.53)
[1] 2.25 (57.15)
[2] 2.625 (66.68)
[1]1.50 (38.1)
[2]1.81 (45.97)
.048
(1.22)
1.40 (35.56)
[1] 2.25 (57.15)
[2] 2.625 (66.68)
.187 DIA
(4.75)
.031
(.787)
.22
(5.59)
.750
(19.05)
1.55 (39.4)
[1] 2.812 (71.42)
[2] 3.125 (79.38)
R .375
(9.53)
1.88
(47.75)

4700-26EW30BB999

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Power Transformers TRANSFORMER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet