Obsolete Product(s) - Obsolete Product(s) Obsolete Product(s) - Obsolete Product(s)
LIS3L02AS4
10/14
6.2 Mechanical Characteristics derived from measurement in the -40°C to +85°Ctemperature range
Figure 12. X axis Zero g Level Change Vs.
Temperature
Figure 13. Y axis Zero g Level Change Vs.
Temperature
Figure 14. Z axis Zero g Level Change Vs.
Temperature
Figure 15. X axis Sensitivity Change Vs.
Temperature
Figure 16. Y axis Sensitivity Change Vs.
Temperature
Figure 17. Z axis Sensitivity Change Vs.
Temperature
1 0.5 0 0.5 1 1.5 2
0
5
10
15
20
25
30
35
Zerog level change (mg/deg. C)
Percent of parts (%)
1 0.5 0 0.5 1
0
5
10
15
20
25
30
35
40
45
50
0g level change (mg/deg. C)
Percent of parts (%)
1 0 1 2 3 4
0
5
10
15
20
25
30
0g level change (mg/deg. C)
Percent of parts (%)
0.03 0.02 0.01 0 0.01 0.02
0
5
10
15
20
25
30
35
40
45
Sensitivity Change(%/deg. C)
Percent of parts (%)
0.03 0.02 0.01 0 0.01 0.02
0
5
10
15
20
25
30
35
40
45
50
Sensitivity Change (%/deg. C)
Percent of parts (%)
0.05 0.04 0.03 0.02 0.01 0 0.01 0.02 0.03
0
5
10
15
20
25
30
35
40
Sensitivity Change (%/deg. C)
Percent of parts (%)
Obsolete Product(s) - Obsolete Product(s)