Regulatory Information
The ACPL-302J is approved by the following organizations:
UL CSA IEC/EN/DIN EN 60747-5-5
Approved under UL 1577, component
recognition program up to V
ISO
= 5000
V
RMS
expected before product release.
Approved under CSA Component Ac-
ceptance Notice #5, File CA 88324.
Approved under:
IEC 60747-5-5:
EN 60747-5-5:
DIN EN 60747-5-5:
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics
Description Symbol Units
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 600 V
rms
for rated mains voltage ≤ 1000 V
rms
I – IV
I – IV
I - IV
I - III
Climatic Classication 40/105/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
1230 V
PEAK
Input-to-Output Test Voltage, Method b
V
IORM
× 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec, Partial discharge < 5 pC
V
PR
2306 V
PEAK
Input-to-Output Test Voltage, Method a
V
IORM
× 1.6 = V
PR
, Type and Sample Test with t
m
= 10 sec, Partial discharge < 5 pC
V
PR
1968 V
PEAK
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 60 sec) V
IOTM
8000 V
PEAK
Safety-limiting values – maximum values allowed in the event of a failure,
(also see Figure 7)
Case Temperature
Input Power
Output Power
Ts
P
S,INPUT
P
S,OUTPUT
175
400
1200
°C
mW
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
> 10
9
Ω
Notes:
1. Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in the application.
Surface mount classication is Class A in accordance with CECCOO802.
2. Refer to IEC/EN/DIN EN 60747-5-5 Optoisolator Safety Standard section of the Avago Regulatory Guide to Isolation Circuits, AV02-2041EN for a
detailed description of Method a and Method b partial discharge test proles.
8