Enhanced Product AD7403-EP
Rev. 0 | Page 5 of 12
PACKAGE CHARACTERISTICS
Table 3.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
I-O
12
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
IC Junction to Ambient Thermal Resistance θ
JA
45 °C/W Thermocouple located at center of package underside,
test conducted on 4-layer board with thin traces
1
The device is considered a 2-terminal device. For AD7403-EP, Pin 1 to Pin 8 are shorted together and Pin 9 to Pin 16 are shorted together.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 4.
Parameter Symbol Value Unit Test Conditions/Comments
Input to Output Momentary Withstand Voltage V
ISO
5000 min V 1 minute duration
Minimum External Air Gap (Clearance) L(I01) 8.3 min
1, 2
mm Measured from input terminals to output
terminals, shortest distance through air
Minimum External Tracking (Creepage) L(I02) 8.3 min
1
mm Measured from input terminals to output
terminals, shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.034 min mm Distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1
3
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table I)
3
1
In accordance with IEC 60950-1 guidelines for the measurement of creepage and clearance distances for a pollution degree of 2 and altitudes ≤2000 m.
2
Consideration must be given to pad layout to ensure the minimum required distance for clearance is maintained.
3
CSA CTI rating for the AD7403-EP is >575 V and therefore Material Group II isolation group.
REGULATORY INFORMATION
Table 5.
UL
1
CSA VDE
2
Recognized under 1577
Component Recognition
Program
1
Approved under CSA Component Acceptance Notice 5A Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
5000 V rms Isolation Voltage
Single Protection
Basic insulation per CSA 60950-1-07 and IEC 60950-1,
830 V rms (1173 V
PEAK
), maximum working voltage
3
Reinforced insulation per DIN V VDE V 0884-10
(VDE V 0884-10):2006-12, 1250 V
PEAK
Reinforced insulation per CSA 60950-1-07 and
IEC 60950-1. 415 V rms (586 V
PEAK
) maximum working
voltage
3
Reinforced insulation per IEC 60601-1, 250 V rms
(353 V
PEAK
) maximum working voltage
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each AD7403-EP is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 15 µA).
2
In accordance with DIN V VDE V 0884-10, each AD7403-EP is proof tested by applying an insulation test voltage ≥ 2344 V
PEAK
for 1 second (partial discharge detection limit = 5 pC).
3
Rating is calculated for a pollution degree of 2 and a Material Group III. The AD7403-EP RI-16-2 package material is rated by CSA to a CTI of >575 V and therefore
Material Group II.