1 of 8
© 2016 TE Connectivity family of companies
All Rights Reserved
| Indicates Change
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.
108-2351
19 AUG 16 Rev H1
IMPACT 100 Ohm Interconnect Systems
1. SCOPE
1.1. Content
This specification defines the performance, tests and quality requirements for the TE Connectivity (TE)
IMPACT 100 Ohm Interconnect Systems which consists of modular groupings of broad-edge coupled
signals with optional integrated guidance. These connectors are two-piece devices, which connect two
printed circuit boards (PCBs). The right angle receptacle connectors (daughtercard) and header pin
connectors (backplane) are through-hole devices with Eye-of-the-Needle (EON) compliant pin terminals.
1.2. Qualification
When tests are performed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be performed using the applicable inspection plan and product drawing.
Successful qualification testing on the subject product line was completed on 25 Feb 11. The
Qualification Test Report number for this testing is 501-743. This documentation is on file at and
available from Engineering Practices and Standards (EPS).
2. APPLICABLE DOCUMENTS
The following documents form a part of this specification to the extent specified herein. Unless
otherwise specified, the latest edition of the document applies. In the event of conflict between the
requirements of this specification and the product drawing, the product drawing shall take precedence.
In the event of conflict between the requirements of this specification and the referenced documents,
this specification shall take precedence.
2.1. TE Connectivity Document
501-743: IMPACT Interconnect Systems (Qualification Test Report)
2.2. Industry Document
EIA-364: Electrical Connector/Socket Test Procedures Including Environmental Classifications
2.3. Reference Document
109-197: TE Test Specifications vs. EIA and IEC Test Methods (Test Specification)
2.4. The header pins are lubricated in the contact area with an approved lubricant according to industry
standard Telcordia GR-1217-CORE, Section 5.3.
3. REQUIREMENTS
3.1. Design and Construction
Product shall be of the design, construction and physical dimensions specified on the applicable product
drawing.