RW-2072 Issue 13 Page 22 of 27 October 2014
TE CONNECTIVITY, SWINDON, UK
While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this specification, TE Connectivity does not guarantee that it is error-
free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE Connectivity reserves
the right to make any adjustments to the information contained herein at any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the
information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are
for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE Connectivity for the latest
dimensions and design specifications.
If this document is printed it becomes uncontrolled.
PROPERTY TEST METHOD UNITS REQUIREMENTS
RW-2072
SECTION
FIRE SAFETY
Fire Propagation
(Aviation Method)
Airbus Directive ABD0031
Issue F, Fire worthiness
requirements pressured section
of fuselage
(Flammability of Heat Shrink
tubing – AITM 2.0038)
---
Burn length Average shall
not exceed 76mm
After flame time average not
exceed 30s
After flame time, dripping
must not exceeed 3s
5.7.1.
Fire Propagation
ASTM D2671 procedure B
Burn time shall not exceed
one minute, and not more
than 25% of indicator flag
shall be burned or charred.
No dripping or flowing. No
burning of cotton.
5.7.3.
EN45545-2
Flammability Hazard Rating
for unlimited interior mass
use:
Based on the following
criteria:
Oxygen Index (OI)
Smoke Density, Ds
Toxicity
BS EN ISO 4589-2:1999
EN ISO 5659-2
NF F 70-100 -1
NF F 70-100 -2
%
---
---
---
Requirement Set R22,
Hazard Rating 3
i
32 Minimum
150 Maximum
0.75 Maximum
5.7.4.
5.7.7.
5.7.9. and
5.7.13.
Surface Flammability,
Flame Spread Index, Is
ASTM E162 --- 35 Maximum 5.7.5.
Specific Optical Smoke
Density, Ds
5.7.6.
Flaming Mode
Specific Optical Density
1.5 minutes
4 minutes
ASTM E 662
---
---
100 Maximum
200 Maximum
Non Flaming Mode
1.5 minutes
4 minutes
---
---
100 Maximum
200 Maximum
i
Unlimited internal use, any operating category and rail car design
RW-2072 Issue 13 Page 23 of 27 October 2014
TE CONNECTIVITY, SWINDON, UK
While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this specification, TE Connectivity does not guarantee that it is error-
free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE Connectivity reserves
the right to make any adjustments to the information contained herein at any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the
information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are
for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE Connectivity for the latest
dimensions and design specifications.
If this document is printed it becomes uncontrolled.
PROPERTY TEST METHOD UNITS REQUIREMENTS
RW-2072
SECTION
FIRE SAFETY
Toxic Gas Generation from
Material Combustion
Carbon Monoxide (CO)
Carbon Dioxide (CO2)
Nitrogen Oxides (NO2)
Sulphur Dioxide (SO2)
Hydrogen Chloride (HCl)
Hydrogen Fluoride (HF)
Hydrogen Bromide (HBr)
Hydrogen Cyanide (HCN)
BSS 7239
Measured at maximum smoke
density. Flaming mode and
non-flaming mode assessed,
worst case reported.
ppm
Maxima:
3500
90000
100
100
500
100
100
100
5.7.10
Effective Heat of
Combustion
ii
Average Heat Release Rate,
3 minutes
Average Extinction area, 3
minutes
ASTM E1354
50kWm
2
applied heat flux with
retainer frame
kW/m
2
m
2
/kg
100
Maximum
500
5.7.11
ii
NFPA 130 does not specify a requirement for small electrical components, the figures stated are based on current best practices for US federal
rail administration and national fire protection association.
RW-2072 Issue 13 Page 24 of 27 October 2014
TE CONNECTIVITY, SWINDON, UK
While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this specification, TE Connectivity does not guarantee that it is error-
free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE Connectivity reserves
the right to make any adjustments to the information contained herein at any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the
information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are
for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE Connectivity for the latest
dimensions and design specifications.
If this document is printed it becomes uncontrolled.
TABLE: 7 Special Requirements for HX-LFH Heat Shrink Sleeving
PROPERTY TEST METHOD UNITS REQUIREMENTS
RW-2072
SECTION
London Underground
Standard 1-085: A3
Non-listed items
Based on the following criteria:
Limited and dispersed
Use
Oxygen Index (OI) BS EN ISO 4589-2:1999 % 30 Minimum 5.7.4.
Smoke Density, Annex D.8.3,
‘A0’
BS6853: 1999, Annex D.8.3 M
3
/g 0.02 Maximum 5.7.8.
Toxicity, Annex B
(using BS6853 cat 1a
requirements), ‘R’
BS 6853: 1999, Annex B
NF X 70-100
--- 1 Maximum 5.7.13.
Toxic Fume, Elemental
Analysis
Use printed product,
London Underground
Standard 1-085 A3 Fire safety
performance of materials.
---
Halogen, Phosphorus,
Silicone or Nitrogen shall
not be intentionaly added or
be present at greater than
trace amounts (300ppm
maximum)
5.7.12.
BS6853
Interior minor use of materials
of mass 100-500g
Based on the following criteria:
Vehicle Category 1a
Oxygen Index (OI) BS EN ISO 4589-2:1999 % 34 Minimum 5.7.4.
Smoke Density, Annex
D.8.3, A0
BS6853: 1999, Annex D.8.3.) M
2
/g 0.017 Maximum 5.7.8.
Toxicity, Annex B, R
BS 6853: 1999, Annex B
NF X 70-100
--- 1.0 Maximum 5.7.13.

EC8466-000

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Wire Labels & Markers HX064WE1DS050X
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union