RW-2072 Issue 13 Page 25 of 27 October 2014
TE CONNECTIVITY, SWINDON, UK
While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this specification, TE Connectivity does not guarantee that it is error-
free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE Connectivity reserves
the right to make any adjustments to the information contained herein at any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the
information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are
for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE Connectivity for the latest
dimensions and design specifications.
If this document is printed it becomes uncontrolled.
PROPERTY TEST METHOD UNITS REQUIREMENTS RW-2072
SECTION
AFNOR NF F 16-101
Category A1 Rolling Stock,
‘Small dimension parts’
iii
Based on the following criteria:
Use the methods below for
flammability, smoke and
toxicity, determine ‘I’ and ‘F’
---
Category A1
NF F 16-101
Grid 10
Flammability, I Rating
(ignitability)
Determine I rating with the
following tests -
I3
Oxygen Index (OI) BS EN ISO 4589-2:1999 % 28 Minimum 5.7.4.
Glow Wire test BS EN 60695-2-11: 2001 ---
Ignition does not persist at
850°C afterglow wire is
withdrawn
5.7.2.
F Rating (Smoke and toxic
gas)
Calculation:
Conventional Toxicity Index,
CIT
Maximum specific optical
density of smoke, Dmax
iv
Rate of smoke production
during first 4 minutes of test,
VOS
4
=D1+D2+D3+D4
2
Smoke Index,
SI= Dmax + VOS4 + C.I.T
100 30 2
Determine F rating with the
following tests -
NF X 70-100, Toxic gas
emission, mass based
method.
NFX 10-702, Determination of
the opacity of smoke in a non-
renewed atmosphere.
F1
5.7.13.
5.7.9.
≤ 20
iii
Situated inside vehicles, individual parts do not exceed 100g, aggregate mass less than 200g/m. Requirements taken from grid 10 of NF 16-101
iv
Where D (number) is the recorded optical density at each minute.