19
AT49BV1604A(T)/1614A(T)
1411FFLASH03/02
Notes: 1. These parameters are characterized and not 100% tested.
2. See t
OE
spec in AC Read Characteristicson page 14.
Data Polling Waveforms
Notes: 1. These parameters are characterized and not 100% tested.
2. See t
OE
spec in AC Read Characteristicson page 14.
Toggle Bit Waveforms
(1)(2)(3)
Notes: 1. Toggling either OE or CE or both OE and CE will operate toggle bit.
The t
OEHP
specification must be met by the toggling input(s).
2. Beginning and ending state of I/O6 will vary.
3. Any address location may be used but the address should not vary.
Data Polling Characteristics
(1)
Symbol Parameter Min Typ Max Units
t
DH
Data Hold Time 10 ns
t
OEH
OE Hold Time 10 ns
t
OE
OE to Output Delay
(2)
ns
t
WR
Write Recovery Time 0 ns
Toggle Bit Characteristics
(1)
Symbol Parameter Min Typ Max Units
t
DH
Data Hold Time 10 ns
t
OEH
OE Hold Time 10 ns
t
OE
OE to Output Delay
(2)
ns
t
OEHP
OE High Pulse 50 ns
t
WR
Write Recovery Time 0 ns
20
AT49BV1604A(T)/1614A(T)
1411FFLASH03/02
Software Product Identification Entry
(1)
Software Product Identification Exit
(1)(6)
Notes: 1. Data Format: I/O15 - I/O8 (Dont Care); I/O7 - I/O0 (Hex)
Address Format: A11 - A0 (Hex), A-1, and A11 - A19 (Dont
Care).
2. A1 - A19 = V
IL
. Manufacturer Code is read for A0 = V
IL
;Device
Code is read for A0 = V
IH
.
Additional Device Code is read for address 0003H
3. The device does not remain in identification mode if
powered down.
4. The device returns to standard operation mode.
5. Manufacturer Code: 1FH(x8); 001FH(x16)
Device Code: C0H (x8) - AT49BV/LV16X4A;
00C0H (x16) - AT49BV/LV16X4A;
C2H (x8) - AT49BV/LV16X4AT;
00C2H (x16) - AT49BV/LV16X4AT.
Additional Device Code: C8H (x8) - AT49BV/LV16X4A(T)
00C8H (x16) - AT49BV/LV16X4A(T)
6. Either one of the Product ID Exit commands can be used.
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA 90
TO
ADDRESS 555
ENTER PRODUCT
IDENTIFICATION
MODE
(2)(3)(5)
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA F0
TO
ADDRESS 555
EXIT PRODUCT
IDENTIFICATION
MODE
(4)
OR
LOAD DATA F0
TO
ANY ADDRESS
EXIT PRODUCT
IDENTIFICATION
MODE
(4)
Sector Lockdown Enable Algorithm
(1)
Notes: 1. Data Format: I/O15 - I/O8 (Dont Care); I/O7 - I/O0 (Hex)
Address Format: A11 - A0 (Hex), A-1, and A11 - A19 (Dont
Care).
2. Sector Lockdown feature enabled.
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA 80
TO
ADDRESS 555
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA 60
TO
SECTOR ADDRESS
PAUSE 200 µs
(2)
21
AT49BV1604A(T)/1614A(T)
1411FFLASH03/02
Status Bit Table
Status Bit
I/O7 I/O6 I/O2
Read Address In Plane A Plane B Plane A Plane B Plane A Plane B
While
Programming in Plane A I/O7
DATA TOGGLE DATA 1 DATA
Programming in Plane B DATA I/O7
DATA TOGGLE DATA 1
Erasing in Plane A 0 DATA TOGGLE DATA TOGGLE DATA
Erasing in Plane B DATA 0 DATA TOGGLE DATA TOGGLE
Erase Suspended & Read
Erasing Sector
1 1 1 1 TOGGLE TOGGLE
Erase Suspended & Read
Non-erasing Sector
DATA DATA DATA DATA DATA DATA
Erase Suspended &
Program Non-erasing Sector
in Plane A
I/O7
DATA TOGGLE DATA TOGGLE DATA
Erase Suspended &
Program Non-erasing Sector
in Plane B
DATA I/O7
DATA TOGGLE DATA TOGGLE

AT49BV1614AT-90TI