Byte23 Name Control Function Type 0 1 PWD
Bit7
Reserved Reserved R - - 0
Bit6
Reserved Reserved R - - 0
Bit5
Reserved Reserved R - - 0
Bit4
R 4096 0
Bit3
R 2048 0
Bit2
R 1024 0
Bit1
R 512 0
Bit0
R 256 0
Byte24 Name Control Function Type 0 1 PWD
Bit7
RW 00 - Direct Drive Mode 01 - Thermal Trigger Mode 1
Bit6
RW 10 - Dynamic PWM Mode 11 - Reserved 0
Bit5
RW 00 - 25KHz 01 - 22KHz 0
Bit4
RW 10 - 27KHz 11 - Reserved 0
Bit3
RW 00 - 1Pole FAN 01 - 2 Poles FAN 0
Bit2
RW 10 - 3 Poles FAN 11 - 4 Poles FAN 1
Bit1
RW 00 - 0 01 - 32 0
Bit0
RW 10 - 64 11 - 128 1
Byte25 Name Control Function Type 0 1 PWD
Bit7
RW 00 - 250ms 01 - 500ms 0
Bit6
RW 10 - 1s 11 - 2s 1
Bit5
RW 1
Bit4
RW 1
Bit3
RW 0
Bit2
RW 00 - 3 01 - 4 0
Bit1
RW 10 - 5 11 - 6 1
Bit0
Reserved Reserved RW - - 0
Byte26 Name Control Function Type 0 1 PWD
Bit7
RW 1 0
Bit6
RW 1/2 0
Bit5
RW 1/4 0
Bit4
RW 1/8 0
Bit3
RW 1/16 0
Bit2
RW 1/32 0
Bit1
RW 1/64 0
Bit0
RW 1/128 0
Byte27 Name Control Function Type 0 1 PWD
Bit7
RW 1/256 0
Bit6
RW 1/512 0
Bit5
RW 1/1024 0
Bit4
RW 0
Bit3
RW 1
Bit2
RW 1
Bit1
RW 00 - 2C 01 - 5C 0
Bit0
RW 10 - 10C 11 - 15C 1
TACH_MEASURE<12:8> MSB of TACH Measurement -
Mode Select Select the FAN Operating Mode
Freq_Sel Select the PWM frequency
Edge FAN Type Selection
Error Range TACH Detect Tolerant Error Rang
Spin-Up Time The Time For Spin-Up
Spin-Up Duty PWM Duty-Cycle For Spin-Up
000 - 30%, 001 - 35%, 010 - 40%,
011 - 45%, 100 - 50%, 101 - 55%,
110 - 60%, 111 - 65%
Spin-Up cnt Time Out Times For Spin-Up
Duty_Cycle<10:3> MSB of PWM Duty-Cycle Setting -
Duty_Cycle<2:0> LSB of PWM Duty-Cycle Setting -
Update Time TACH Detect Update Time
000 - 100ms, 001 - 200ms, 010 - 300ms, 011 - 400m,
100 - 500ms, 101 - 600ms, 110 - 700ms, 111 - 800ms
T_Hy s
Temperature Hysteresis For FAN's
Trigger Point