Document Number: 002-08308 Rev. *C Page 7 of 24
7. Pin Setting
When changing the pin setting, the stabilization wait time for the modulation clock is required. The stabilization wait time for the mod-
ulation clock takes the maximum value of Lock-Up time in “AC Characteristics of Electrical Characteristics”.
7.1 Modulation Enable Setting
Note: CY88152A-100 and CY88152A-110 do not have XENS pin.
7.2 SEL Modulation Rate Setting
Note: The modulation rate can be changed at the level of the terminal.
7.3 Frequency Setting
Note: CY88152A-100 and CY88152A-110 do not have FREQ pin.
Note: CY88152A-101, CY88152A-111 and CY88152A-112 have neither FREQ0 pin nor FREQ1 pin.
XENS Modulation
L Modulation CY88152A-101,
CY88152A-111, CY88152A-112
H No modulation
SEL Modulation Rate Remarks
L ± 0.5% CY88152A-111,
CY88152A-112
Center spread
− 1.0% CY88152A-100,
CY88152A-101
Down spread
H ± 1.5% CY88152A-111,
CY88152A-112
Center spread
− 3.0% CY88152A-100,
CY88152A-101
Down spread
FREQ Frequency
L 16.6 MHz to 40 MHz CY88152A-101, CY88152A-111
40 MHz to 80 MHz CY88152A-112
H 33 MHz to 67 MHz CY88152A-101, CY88152A-111
66 MHz to 134 MHz CY88152A-112
FREQ1 FREQ0 Frequency
L L 16.6 MHz to 40 MHz CY88152A-100
L H 33 MHz to 67 MHz
H L 40 MHz to 80 MHz
H H 66 MHz to 134 MHz