Description
The HCPL-7860/HCPL-786J Optically Isolated Modulator
and HCPL-0872 Digital Interface IC or digital lter together
form an isolated programmable two-chip analog-to-digital
converter. The isolated modulator allows direct measure-
ment of motor phase currents in power inverters.
In operation, the HCPL-7860/HCPL-786J Isolated Modula-
tor converts a low-bandwidth analog input into a high-
speed one-bit data stream by means of a Sigma-Delta
(Σ−∆) over-sampling modulator. This modulation provides
for high noise margins and excellent immunity against
isolation-mode transients. The modulator data and on-
chip sampling clock are encoded and transmitted across
the isolation boundary where they are recovered and de-
coded into separate high-speed clock and data channels.
NOTE: A 0.1 μF bypass capacitor must be connected between pins VDD1 and GND1 and between pins VDD2 and GND2.
SIGMA
DELTA
MOD./
ENCODE
DECODE
1
2
3
4
8
7
6
5
Input
Current
HCPL-0872
or
Digital Filter
MCU
or
DSP
HCPL-7860
HCPL-7860/HCPL-786J
Optically Isolated Sigma-Delta (S-D) Modulator
Data Sheet
Features
12-bit Linearity
200 ns Conversion Time
(Pre-Trigger Mode 2 with HCPL-0872)
12-bit Eective Resolution with 5 µs Signal Delay
(14-bit with 102 µs) (with HCPL-0872)
Fast 3 µs Over-Range Detection (with HCPL-0872)
± 200 mV Input Range with Single 5 V Supply
1% Internal Reference Voltage Matching
Oset Calibration (with HCPL-0872)
-40°C to +85°C Operating Temperature Range
15 kV/µs Isolation Transient Immunity
Safety Approval: UL 1577, CSA and IEC/EN/DIN EN
60747-5-5
Applications
Motor Phase and Rail Current Sensing
Data Acquisition Systems
Industrial Process Control
Inverter Current Sensing
General Purpose Current Sensing and Monitoring
Lead (Pb) Free
RoHS 6 fully
compliant
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this
component to prevent damage and/or degradation which may be induced by ESD. The components
featured in this datasheet are not to be used in military or aerospace applications or environments.
2
Pin Description
Symbol Description Symbol Description
V
DD1
Supply voltage input (4.5 V to 5.5 V) V
DD2
Supply voltage input (4.5 V to 5.5 V)
V
IN+
Positive input (± 200 mV recommended) MCLK Clock output (10 MHz typical)
V
IN-
Negative input (normally connected to GND1) MDAT Serial data output
GND1 Input ground GND2 Output ground
HCPL-7860
1
2
3
4
8
7
6
5
V
DD1
V
IN+
V
IN-
GND1
V
DD2
MCLK
MDAT
GND2
SHIELD
ISOLATION
BOUNDARY
DECODE
SIGMA-
DELTA
MOD./
ENCODE
5
6
12
11
NC
NC
NC
MDAT
7
10
NC NC
8
9
GND1
GND2
1
2
16
15
V
DD1
V
IN+
GND2
NC
3
14
V
IN-
V
DD2
4
13
NC MCLK
SIGMA-
DELTA
MOD./
ENCODER
DECODER
HCPL-786J
Ordering Information
HCPL-7860 is UL Recognized with 3750 Vrms for 1 minute per UL1577. HCPL-786J is UL Recognized with 5000 Vrms for
1 minute per UL1577.
Part number
Option
Package
Surface
Mount
Gull
Wing
Tape
& Reel
IEC/EN/DIN EN
60747-5-5 Quantity
RoHS
Compliant
Non-RoHS
Compliant
HCPL-7860 -000E No option 300 mil
DIP-8
X 50 per tube
-300E #300 X X X 50 per tube
-500E #500 X X X X 1000 per reel
HCPL-786J -000E No option SO-16 X 45 per tube
-500E #500 X X X 850 per reel
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
Example 1:
HCPL-7860-500E to order product of Gull Wing Surface Mount package in Tape and Reel packaging with IEC/EN/DIN
EN 60747-5-5 Safety Approval in RoHS compliant.
Example 2:
HCPL-786J to order product of SO-16 package in tube packaging and non-RoHS compliant.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
Remarks: The notation ‘#XXX’ is used for existing products, while (new) products launched since 15th July 2001 and RoHS
compliant option will use ‘-XXXE’.
Note: NC = No connection. Leave oating.
3
Package Outline Drawings
8-pin DIP Package
8-pin Gull Wing Surface Mount Option 300
1.080 ± 0.320
(0.043 ± 0.013)
2.54 ± 0.25
(0.100 ± 0.010)
0.51 (0.020) MIN.
0.65 (0.025) MAX.
4.70 (0.185) MAX.
2.92 (0.115) MIN.
5 TYP.
0.254
+ 0.076
- 0.051
(0.010
+ 0.003)
- 0.002)
7.62 ± 0.25
(0.300 ± 0.010)
6.35 ± 0.25
(0.250 ± 0.010)
9.80 ± 0.25
(0.386 ± 0.010)
1.78 (0.070) MAX.
1.19 (0.047) MAX.
DIMENSIONS IN MILLIMETERS AND (INCHES).
OPTION NUMBERS 300 AND 500 NOT MARKED.
NOTE: FLOATING LEAD PROTRUSION IS 0.25 mm (10 mils) MAX.
5678
4321
3.56 ± 0.13
(0.140 ± 0.005)
0.635 ± 0.25
(0.025 ± 0.010)
12 ° NOM.
9.65 ± 0.25
(0.380 ± 0.010)
0.635 ± 0.130
(0.025 ± 0.005)
7.62 ± 0.25
(0.300 ± 0.010)
5
6
7
8
4
3
2
1
9.80 ± 0.25
(0.386 ± 0.010)
6.350 ± 0.25
(0.250 ± 0.010)
1.016 (0.040)
1.27 (0.050)
10.9 (0.430)
2.0 (0.080)
LAND PATTERN RECOMMENDATION
1.080 ± 0.320
(0.043 ± 0.013)
3.56 ± 0.13
(0.140 ± 0.005)
1.780
(0.070)
MAX.
1.19
(0.047)
MAX.
2.54
(0.100)
BSC
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES).
NOTE: FLOATING LEAD PROTRUSION IS 0.5 mm (20 mils) MAX.
0.254
+ 0.076
- 0.051
(0.010
+ 0.003)
- 0.002)
Lead Free
UL Logo
Device Part Number
Special Program
Code
EEE
Avago
NNNN
YYWW
A
Test Rating Code
Z
P
Pin 1 Dot
Lot ID
Date Code
Lead Free
UL Logo
Device Part Number
Special Program
Code
EEE
Avago
NNNN
YYWW
A
Test Rating Code
Z
P
Pin 1 Dot
Lot ID
Date Code

HCPL-7860-000E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Data Acquisition ADCs/DACs - Specialized Isolated Modulator
Lifecycle:
New from this manufacturer.