FP1505R1-R10-R

Current range from 24 to 105 amps
Frequency range up to 1MHz
RoHS compliant
Applications
Multi-phase regulators
Voltage Regulator Module (VRM)
Desktop and server VRMs and EVRDs
Data networking and storage systems
Notebook regulators
Graphics cards and battery power systems
Point of load modules
DCR current sensing
Environmental Data
Storage temperature range: -40°C to +125°C
Operating temperature range: -40°C to +125°C
(with derated current)
Solder reflow temperature: J-STD-020D compliant
Packaging
Supplied in tape-and-reel packaging, 744 parts per reel,
13” diameter reel
Description
Halogen Free
125°C maximum total operating temperature
7.0 x 15.0 x 5.0mm surface mount package
Ferrite core material
High current handling capability, low core loss
Designed for high speed, high current switch mode applications
Controlled DCR tolerance for sensing circuits
Inductance range from 100nH to 400nH
High Current, High Frequency, Power Inductors
FLAT-PAC™ FP1505 Series
0409 BU-SB09350 Page 1 of 4 Data Sheet: 4365
SMD Device
SMD Device
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 1.0V
rms
, 0.0Adc
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 1.0V
rms
,I
sat
1
3I
rms
: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of other
heat generating components will affect the temperature rise. It is recommended that the
temperature of the part not exceed 125°C under worst case operating conditions verified in the
end application.
4I
sat
1: Peak current for approximately 20% rolloff at +25°C.
5I
sat
2: Peak current for approximately 20% rolloff at +125°C.
6 K-factor: Used to determine B
p-p
for core loss (see graph). B
p-p
= K * L * ΔI * 10
-3
.B
p-p
:(Gauss), K:
(K-factor from table), L: (Inductance in nH), ΔI (Peak-to-peak ripple current in amps).
7 Part Number Definition: FP1505Rx-Rxx-R
• FP1505 = Product code and size
• Rx= DCR indicator
• Rxx= Inductance value in uH, R = decimal point
• -R suffix = RoHS compliant
Product Specifications
Part OCL
1
FLL
2
I
rms
3
I
sat
1
4
I
sat
2
5
DCR (mΩ)
Number
7
± 10% (nH) Min. (nH) (Amps) (Amps) @25°C (Amps) @125°C @20°C K-factor
6
FP1505R1-R10-R 100 72 105 90 356.3
FP1505R1-R12-R 120 86 87 75 356.3
FP1505R1-R15-R 150 108
53
72 60
0.47 ± 7%
356.3
FP1505R1-R25-R 250 180 42 32 356.3
FP1505R1-R30-R 300 217 35 26 356.3
FP1505R1-R40-R 400 288 24 19.5 356.3
HALOGEN
HF
FREE
2
Schematic
1
15
4.50 (2x)
2.50 (2x)
6.7
± 0.3
1.9 ref.
(2x)
Front View
2.8 ref.
5.00 Max
14.7
± 0.3
1
2
Recommended Pad Layout
Side ViewTop View
1505Rx
Rxx
wwllyy R
2.0
ref
a
b
Dimensions - mm
User direction of feed
S ection A -A
A
A
5.4
1.5 dia
1.5 dia
4.0
2.0
16.0
1.75
11.5
24.0
± 0.3
15.4
7.4
1505Rx
Rxx
wwllyy R
0
5
10
15
20
25
30
35
40
45
50
00.40.81.21.62
Total Loss (W)
Temperature Rise (°C)
Part Marking: Coiltronics logo 1505Rx Rx = DCR indicator Rxx = Inductance value in μH. (R = Decimal point). wwllyy = Date code R = Revision level
Supplied in tape-and-reel packaging, 744 parts per reel, 13” diameter reel.
Packaging Information - mm
Temperature Rise vs.Total Loss
0409 BU-SB09350 Page 2 of 4 Data Sheet: 4365
The nominal DCR is measured between points “a” and “b”
0409 BU-SB09350 Page 3 of 4 Data Sheet: 4365
Core Loss vs. B
0.0001
0.001
0.01
0.1
1
10
100 1000 10000
B (Ga u s s )
Core Loss (W)
1
MHz
500
kHz
300
kHz
200
kHz
100
kHz
p-p
p-p
% of OCL vs. % of I
sat
1
0%
20%
40%
60%
80%
100%
0% 20% 40% 60% 80% 100% 120% 140%
% of I
sa t
1
% of OCL
+125°C
+25°C
-40°C
Inductance Characteristics
Core Loss

FP1505R1-R10-R

Mfr. #:
Manufacturer:
Description:
Fixed Inductors 72nH 53A Flat-Pac FP1505
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: