Obsolete Product(s) - Obsolete Product(s)
Absolute maximum ratings TSH120
2/13
1 Absolute maximum ratings
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. All voltage values are measured with respect to the ground pin.
6V
V
in
Input voltage range
(2)
2. The magnitude of input and output voltage must never exceed V
CC
+0.3V.
2V
T
oper
Operating free air temperature range -40 to +105 °C
T
stg
Storage temperature -65 to +150 °C
T
j
Maximum junction temperature 150 °C
R
thja
Thermal resistance junction to ambient 430 °C/W
R
thjc
Thermal resistance junction to case 58 °C/W
P
max
Maximum power dissipation
(3)
for T
j
=150°C
T
a
=+25°C
T
a
=+85°C
3. Short-circuits can cause excessive heating. Destructive dissipation can result from short-circuits on
amplifiers.
290
150
mW
ESD
HBM: human body model
(4)
except pin-4
pin-4
4. Human body model: A 100pF capacitor is charged to the specified voltage, then discharged through a
1.5kΩ resistor between two pins of the device. This is done for all couples of connected pin combinations
while the other pins are floating.
2
1.5
kV
MM: machine model
(5)
5. Machine model: A 200pF capacitor is charged to the specified voltage, then discharged directly between
two pins of the device with no external series resistor (internal resistor < 5Ω). This is done for all couples of
connected pin combinations while the other pins are floating. This is a minimum value.
200 V
Latch-up immunity 200 mA
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. Tested in full production at +2.5V and +3.3V single supply voltage.
2.2 to 5.5 V
Obsolete Product(s) - Obsolete Product(s)