Typical operating characteristics STM1001
10/18 Doc ID 10373 Rev 6
Figure 9. Normalized reset threshold vs. temperature
Figure 10. Max transient duration not causing reset pulse vs. reset comparator
overdrive
AI07882
0.993
0.994
0.995
0.996
0.997
0.998
0.999
1.001
1.000
1.002
1.003
–40 –20 0 20 40 60 80
Temperature (°C)
Normalized Treshold
L/M
R/S/T
AI07883
0.00
100.00
200.00
300.00
400.00
500.00
600.00
700.00
1 10 100 1000
Reset Comparator Overdrive, V
RST
– V
CC
(mV)
Maximum Transient Duration (µs)
R/S/T
L/M
STM1001 Maximum ratings
Doc ID 10373 Rev 6 11/18
4 Maximum ratings
Stressing the device above the rating listed in the absolute maximum ratings table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the operating sections of
this specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability. Refer also to the STMicroelectronics SURE
Program and other relevant quality documents.
Table 2. Absolute maximum ratings
Symbol Parameter Value Unit
T
STG
Storage temperature (V
CC
off) –55 to 150 °C
T
SLD
(1)
1. Reflow at peak temperature of 260 °C. The time above 255 °C must not exceed 30 seconds.
Lead solder temperature for 10 seconds 260 °C
V
IO
Input or output voltage –0.3 to V
CC
+0.3 V
V
CC
Supply voltage –0.3 to 7.0 V
I
O
Output current 20 mA
P
D
Power dissipation 320 mW
DC and AC parameters STM1001
12/18 Doc ID 10373 Rev 6
5 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 3: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 3. Operating and AC measurement conditions
Figure 11. AC testing input/output waveforms
Parameter STM1001 Unit
V
CC
supply voltage 1.0 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Input rise and fall times 5ns
Input pulse voltages 0.2 to 0.8 V
CC
V
Input and output timing ref. voltages 0.3 to 0.7 V
CC
V
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC

STM1001TWX6F

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Supervisory Circuits RESET CIRCUIT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union