Data Sheet ADuM5020/ADuM5028
Rev. 0 | Page 9 of 18
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 13.
Parameter Rating
Storage Temperature (T
ST
) −55°C to +150°C
Ambient Operating Temperature (T
A
) −40°C to +125°C
Supply Voltages (V
DDP
, V
ISO
)
1
−0.5 V to +7.0 V
V
ISO
Supply Current
ADuM5020 100 mA
60 mA
DDI
ADuM5028
Input Voltage (PDIS, V
SEL
)
1, 2
Common-Mode Transients
3
−200 kV/µs to +200 kV/µs
1
All voltages are relative to their respective ground.
2
V
DDI
is the input side supply voltage.
3
Common-mode transients refer to common-mode transients across the
insulation barrier. Common-mode transients exceeding the absolute
maximum ratings may cause latch-up or permanent damage.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Table 14. Maximum Continuous Working Voltage
Supporting 50-Year Minimum Lifetime
1
Parameter Max Unit
Applicable
Certification
AC Voltage
Bipolar Waveform 560 V peak
50-year operation
Unipolar Waveform
Basic Insulation 560 V peak
50-year operation
DC Voltage
Basic Insulation 1000 V peak
50-year operation
1
Maximum continuous working voltage refers to the continuous voltage
magnitude imposed across the isolation barrier. See the Insulation Lifetime
section for more information.
ESD CAUTION