Data Sheet ADuM5020/ADuM5028
Rev. 0 | Page 7 of 18
Table 11. ADuM5028 VDE Characteristics
Description Test Conditions/Comments Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage 150 V rms I to IV
For Rated Mains Voltage 300 V rms I to III
For Rated Mains Voltage 400 V rms I to II
Climatic Classification 40/125/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
565 V peak
Input to Output Test Voltage, Method b1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1059 V peak
Input to Output Test Voltage, Method a
V
PR
After Environmental Tests Subgroup 1 V
IORM
× 1.5 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec,
partial discharge < 5 pC
V
pd(m)
848 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec,
partial discharge < 5 pC
V
pd(m)
678 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 sec V
IOTM
4242 V peak
Withstand Isolation Voltage 1 minute withstand rating V
ISO
3000 V rms
Surge Isolation Voltage Reinforced V
IOSM(TEST)
= 10 kV; 1.2 µs rise time; 50 µs, 50% fall time V
IOSM
6000 V peak
Safety Limiting Values Maximum value allowed in the event of a failure
(see Figure 4)
Case Temperature T
S
150 °C
Total Power Dissipation at 25°C
I
S1
1.56
W
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
ADuM5020/ADuM5028 Data Sheet
Rev. 0 | Page 8 of 18
0
0.5
1.0
1.5
2.0
2.5
3.0
0 50 100 150 200
AMBIENT TEMPERATURE (°C)
SAFE LIMITING POWER (W)
16520-002
Figure 3. ADuM5020 Thermal Derating Curve, Dependence of Safety Limiting
Values with Ambient Temperature per DIN V VDE V 0884-10
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0 50 100 150 200
SAFETY LIMITING POWER (W)
AMBIENT TEMPERATURE (°C)
16520-104
Figure 4. ADuM5028 Thermal Derating Curve, Dependence of Safety Limiting
Values with Ambient Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 12.
Parameter Symbol Min Typ Max Unit
Operating Temperature
1
T
A
40
+125
°C
Supply Voltages
2
V
DDP
V
DDP
at V
ISO
= 3.135 V to
3.465 V
4.5 5.5 V
V
DDP
at V
ISO
= 4.75 V to
5.25 V
4.5 5.5 V
1
Operation at >85°C requires reduction of the maximum load current.
2
Each voltage is relative to its respective ground.
Data Sheet ADuM5020/ADuM5028
Rev. 0 | Page 9 of 18
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 13.
Parameter Rating
Storage Temperature (T
ST
) 55°C to +150°C
Ambient Operating Temperature (T
A
) 40°C to +125°C
Supply Voltages (V
DDP
, V
ISO
)
1
0.5 V to +7.0 V
V
ISO
Supply Current
ADuM5020 100 mA
60 mA
0.5 V to V
DDI
+ 0.5 V
ADuM5028
Input Voltage (PDIS, V
SEL
)
1, 2
Common-Mode Transients
3
200 kV/µs to +200 kV/µs
1
All voltages are relative to their respective ground.
2
V
DDI
is the input side supply voltage.
3
Common-mode transients refer to common-mode transients across the
insulation barrier. Common-mode transients exceeding the absolute
maximum ratings may cause latch-up or permanent damage.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Table 14. Maximum Continuous Working Voltage
Supporting 50-Year Minimum Lifetime
1
Parameter Max Unit
Applicable
Certification
AC Voltage
Bipolar Waveform 560 V peak
50-year operation
Unipolar Waveform
Basic Insulation 560 V peak
50-year operation
DC Voltage
Basic Insulation 1000 V peak
50-year operation
1
Maximum continuous working voltage refers to the continuous voltage
magnitude imposed across the isolation barrier. See the Insulation Lifetime
section for more information.
ESD CAUTION

ADUM5028-5BRIZ-RL

Mfr. #:
Manufacturer:
Analog Devices / Linear Technology
Description:
Switching Voltage Regulators isoPower 3kV,
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union