SC628A
4
Parameter Symbol Conditions Min Typ Max Units
Fault Protection (continued)
Undervoltage Lockout
V
UVLO
Increasing V
IN
2.7 V
V
UVLO-HYS
Hysteresis 800 mV
Charge Pump Electrical Speci cations
Maximum Total Output
Current
I
OUT(MAX)
V
IN
> 3.5V, V
OUT(MAX)
= 4.0V 1000 mA
Flash Current Settling Time t
FL_SET
maximum time for current to settle 1 ms
Flash Current Setting I
FL
Nominal setting for FL 25 1000 mA
Flash Current Accuracy I
FL_ACC
V
IN
= 3.7V, I
FL
= 450mA, T
A
= 25°C -13 ± 5 13 %
1x Mode to 1.5x Mode
Falling Transition Voltage
V
TRANS1x
I
OUT
= 150mA, V
OUT
= 3.3V 3.37 V
1.5x Mode to 2x Mode
Falling Transition Voltage
V
TRANS1.5x
I
OUT
= 150mA, V
OUT
= 4.5V
(2)
3.3 V
Current Sink O -State
Leakage Current
I
BLn
V
IN
= V
FL
= 4.2V 0.1 1 μA
Pump Frequency f
PUMP
V
IN
= 3.2V 250 kHz
Digital I/O Electrical Speci cations (FLEN, EN)
Input High Threshold V
IH
V
IN
= 5.5V 1.4 V
Input Low Threshold V
IL
V
IN
= 3.0V 0.4 V
Input High Current I
IH
V
IN
= 5.5V -1 +1 μA
Input Low Current I
IL
V
IN
= 5.5V -1 +1 μA
I
2
C Interface
Interface complies with slave mode I
2
C interface as described by Philips I
2
C speci cation version 2.1 dated January, 2000.
Digital Input Voltage
V
B-IL
0.4 V
V
B-IH
1.4 V
SDA Output Low Level I
DIN
(SDA) ≤ 3mA 0.4 V
Digital Input Current I
B-IN
-0.2 0.2 μA
Hysteresis of
Schmitt Trigger Inputs
V
HYS
0.1 V
Maximum Glitch Pulse
Rejection
t
SP
50 ns
I/O Pin Capacitance C
IN
10 pF
Electrical Characteristics (continued)
SC628A
5
Electrical Characteristics (continued)
Parameter Symbol Conditions Min Typ Max Units
I
2
C Timing
Clock Frequency f
SCL
400 440 kHz
SCL Low Period
(3)
t
LOW
1.3 μs
SCL High Period
(3)
t
HIGH
0.6 μs
Data Hold Time
(3)
t
HD_DAT
s
Data Setup Time
(3)
t
SU_DAT
250 ns
Setup Time for Repeated
START Condition
(3)
t
SU_STA
0.6 μs
Hold Time for Repeated
START Condition
(3)
t
HD_STA
0.6 μs
Setup Time for STOP
Condition
(3)
t
SU_STO
0.6 μs
Bus-Free Time Between
STOP and START
(3)
t
BUF
1.3 μs
Interface Start-up Time
(3)
t
EN
Bus Start-up Time After EN Pin is Pulled High 1 ms
Notes:
(1) Once tripped,  ash output will remain disabled until FLEN pin is cycled or reset via serial interface.
(2) Test voltage is V
OUT
= 4.5V — a relatively extreme LED voltage — to force a transition during test. Typically V
OUT
= 3.3V for the white LED at
100mA.
(3) Guaranteed by design
SC628A
6
Typical Characteristics
Spotlight Current — 25mA
19
21
23
25
27
29
31
2.7
3
3.3
3.63.9
4.2
V
IN
(V)
I
FL
(mA)
V
OUT
= 2.97V, I
OUT
= 25mA, T
A
= 25°C
Flash Current — 400mA
Flash Current — 875mA
Spotlight Current — 100mA
Spotlight Current — 275mA Flash Current — 1000mA
340
360
380
400
420
440
460
2.733.33.6
3.94.2
V
IN
(V)
I
FL
(mA)
V
OUT
= 3.41V, I
OUT
= 400mA, T
A
= 25°C
85
90
95
100
105
110
115
2.73
3.3
3.6
3.94.2
V
IN
(V)
I
FL
(mA)
V
OUT
= 3.14V, I
OUT
= 100mA, T
A
= 25°C
200
225
250
275
300
325
350
2.73
3.3
3.63.94.2
V
IN
(V)
I
FL
(mA)
V
OUT
= 3.32V, I
OUT
= 275mA, T
A
= 25°C
V
OUT
=
3
.
69V
,
I
OUT
=
8
75m
A
,
T
A
=
2
5
°C
I
FL
(mA)
V
IN
(V)
575
675
775
875
975
1075
1175
2.733.33.63.94.2
V
OUT
= 3.72V, I
OUT
= 1000mA, T
A
= 25°C
I
FL
(
m
A)
V
IN
(V)
700
800
900
1000
1100
1200
1300
2.7
3
3.33.6
3.94.2

SC628AULTRT

Mfr. #:
Manufacturer:
Semtech
Description:
LED Lighting Drivers LED DRIVER IC WITH 1A FLASH
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet