Electrical characteristics VN5770AK-E
10/34 Doc ID 13228 Rev 6
Table 7. Logic input
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
=0.9V 1 PA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
=2.1V 10 PA
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
=1mA 5.5 7 V
I
IN
= -1mA -0.7 V
Table 8. Protection and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC Short circuit
current
V
CC
=13V 6 8.5 12 A
5V<V
CC
<36V 12 A
I
limL
Short circuit current
during thermal cycling
V
CC
=13V; T
R
<T
j
<T
TSD
3.5 A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature T
RS
+ 1 T
RS
+ 5 °C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
7°C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
=1A; V
IN
= 0; L = 20mH V
CC
-41 V
CC
-46 V
CC
-52 V
V
ON
Output voltage drop
limitation
I
OUT
= 0.03A;
T
j
= -40°C to 150°C
(see Figure 4)
25 mV
Obsolete Product(s) - Obsolete Product(s)