PLD E 400 W ...
106445_en_03 PHOENIX CONTACT 7 / 10
5 Safety notes 6 Illuminance distribution
The illuminance distribution depends on the length of the
light. Please refer to the figures below for the illuminance
distribution.
Figure 1 Lighting level distribution in Lux
PLDE400W250 (installation depth of the
control cabinet plate d=200mm)
WARNING: Explosion hazard
Do not install and operate the light in
potentially explosive spaces!
CAUTION: Impaired vision
Looking at the light continually can
temporarily impair vision. This can increase
the danger of accidents. Therefore do no look
at a light source for a long period.
NOTE: Damage to the electronics
The IP20 degree of protection (IEC 60529/EN
60529) of the device is intended for use in a
clean and dry environment.
Do not subject the device to mechanical and/
or thermal loads that exceed the specified
limits.
NOTE
Before any work on the light, always switch off
the supply voltage and ensure it cannot be
switched on again!
0,00 m 0,95 m
2,00 m
0,00 m
5
20
30
30
30
30
30
30
30
30
60
60
60
60
60
60
60
60
60
90 90
90 90
90
90
20
20
20
20
20
20
20
10
30
10
10
5
5
PLD E 400 W ...
106445_en_03 PHOENIX CONTACT 8 / 10
Figure 2 Lighting level distribution in Lux
PLDE400W375 (installation depth of the
control cabinet plate d=200mm)
Figure 3 Lighting level distribution in Lux
PLDE400W500 (installation depth of the
control cabinet plate d=200mm)
0,00 m 0,95 m
2,00 m
0,00 m
10
15
15
20
20
30
30
20
30
60
60
60
60
60
60
60
60
60
60
120
120
120
120
120
120
120
120
180
180
180
180
180
180
240
240
0,00 m 0,95 m
2,00 m
0,00 m
15
20
20
30
30
40
40
60
60
60
80
80
80
80
80
80
60
40
30
160
160
160
160
160
160
160
160
160
160
80
240
240
240
240
240
320
320
320
320
320
PLD E 400 W ...
106445_en_03 PHOENIX CONTACT 9 / 10
7 Pin assignment
To supply power to the light, connect the cable to the X01IN
connector.
Figure 4 Connection of the supply voltage of a light
To connect multiple lights in series, connect the X02OUT
output of one light to the X01IN input of the following light.
Figure 5 Forwarding of the supply voltage with the
series connection of lights
Pin assignment of the M8 connectors
4
3
1
X01 IN
4
3
1
X02 OUT
Pin Assignment Conductor
color
Note
1+24 VDC Brown Power supply to the
light
3GND Blue
4+24 V DC
(switched)
Black Signal from door
position switch for
controlling the light in
mode A
Only use Phoenix Contact accessories!
NOTE: device damage
Make sure that the total current consumed by
all the lights used in a series connection does
not exceed 2A.