ADuM230D/ADuM230E/ADuM231D/ADuM231E Data Sheet
Rev. A | Page 10 of 21
REGULATORY INFORMATION
See Table 17, Table 18, and the Insulation Lifetime section for details regarding recommended maximum working voltages for specific
cross-isolation waveforms and insulation levels.
Table 12. RW-16 Wide Body [SOIC_W] Package
UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending)
Recognized Under 1577
Component Recognition
Program
1
Approved under CSA Component Acceptance
Notice 5A
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10):2006-12
2
Certified by
CQC11-471543-2012,
GB4943.1-2011
Single Protection, 5000 V rms
Isolation Voltage
CSA 60950-1-07+A1+A2 and IEC 60950-1,
second edition, +A1+A2:
Reinforced insulation, V
IORM
=
849 peak, V
IOSM
= 8000 V peak
Basic insulation at
780 V rms (1103 V peak)
Double Protection, 5000 V rms
Isolation Voltage
Basic insulation at 780 V rms (1103 V peak) Basic insulation, V
IORM
= 849 V peak,
V
IOSM
= 12 kV peak
Reinforced insulation at
389 V rms (552 V peak),
tropical climate, altitude
≤5000 meters
Reinforced insulation at 390 V rms (552 V peak)
IEC 60601-1 Edition 3.1:
Basic insulation (1 means of patient protection
(1 MOPP)), 490 V rms (686 V peak)
Reinforced insulation (2 MOPP), 238 V rms
(325 V peak)
CSA 61010-1-12 and IEC 61010-1 third edition:
Basic insulation at 300 V rms mains, 780 V
secondary (1103 V peak)
Reinforced insulation at 300 V rms Mains,
390 V secondary (552 V peak)
File E214100 File 205078 File 2471900-4880-0001 File (pending)
1
In accordance with UL 1577, each ADuM230D/ADuM230E/ADuM231D/ADuM231E is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec.
2
In accordance with DIN V VDE V 0884-10, each ADuM230D/ADuM230E/ADuM231D/ADuM231E is proof tested by applying an insulation test voltage ≥ 1018 V peak for
1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
Table 13. RI-16 -2 Wide Body Increased Creepage [SOIC_IC] Package
UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending)
Recognized Under 1577
Component Recognition
Program
1
Approved under CSA Component Acceptance
Notice 5A
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10):2006-12
2
Certified by
CQC11-471543-2012,
GB4943.1-2011
Single Protection, 5000 V rms
Isolation Voltage
CSA 60950-1-07+A1+A2 and IEC 60950-1,
second edition, +A1+A2:
Reinforced insulation, V
IORM
=
849 peak, V
IOSM
= 8000 V peak
Basic insulation at
830 V rms (1174 V peak)
Double Protection, 5000 V rms
Isolation Voltage
Basic insulation at 830 V rms (1174 V peak) Basic insulation, V
IORM
= 849 V peak,
V
IOSM
= 12 kV peak
Reinforced insulation at
415 V rms (587 V peak),
tropical climate, altitude
≤5000 meters
Reinforced insulation at 415 V rms (587 V peak)
IEC 60601-1 Edition 3.1:
Basic insulation (1 means of patient protection
(1 MOPP)), 519 V rms (734 V peak)
Reinforced insulation (2 MOPP), 261 V rms
(369 V peak)
CSA 61010-1-12 and IEC 61010-1 third edition:
Basic insulation at 300 V rms mains, 830 V
secondary (1174 V peak)
Reinforced insulation at 300 V rms Mains,
390 V secondary (587 V peak)
File E214100 File 205078 File 2471900-4880-0001 File (pending)
1
In accordance with UL 1577, each ADuM230D/ADuM230E/ADuM231D/ADuM231E is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec.
2
In accordance with DIN V VDE V 0884-10, each ADuM230D/ADuM230E/ADuM231D/ADuM231E is proof tested by applying an insulation test voltage ≥ 1018 V peak for
1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
Data Sheet ADuM230D/ADuM230E/ADuM231D/ADuM231E
Rev. A | Page 11 of 21
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Protective circuits ensure the maintenance
of the safety data. The * marking on packages denotes DIN V VDE V 0884-10 approval.
Table 14.
Description Test Conditions/Comments Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to III
Climatic Classification 40/125/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
849 V peak
Input to Output Test Voltage, Method B1
V
IORM
× 1.875 = V
pd (m)
, 100% production test,
t
ini
= t
m
= 1 sec, partial discharge < 5 pC
V
pd (m)
1592 V peak
Input to Output Test Voltage, Method A V
pd (m)
After Environmental Tests Subgroup 1
V
IORM
× 1.5 = V
pd (m)
, t
ini
= 60 sec, t
m
= 10 sec,
partial discharge < 5 pC
1274 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
pd (m)
, t
ini
= 60 sec, t
m
= 10 sec,
partial discharge < 5 pC
1019 V peak
Highest Allowable Overvoltage V
IOTM
8000 V peak
Surge Isolation Voltage Basic
V
PEAK
= 12.8 kV, 1.2 µs rise time, 50 µs,
50% fall time
V
IOSM
12,000 V peak
Surge Isolation Voltage Reinforced
V
PEAK
= 12.8 kV, 1.2 µs rise time, 50 µs,
50% fall time
V
IOSM
8000 V peak
Safety Limiting Values
Maximum value allowed in the event of a
failure (see Figure 5)
Maximum Junction Temperature T
S
150 °C
Total Power Dissipation at 25°C P
S
2.78 W
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Figure 5. Thermal Derating Curve, Dependence of Safety Limiting Values
with Ambient Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 15.
Parameter Symbol Rating
Operating Temperature T
A
−40°C to +125°C
Supply Voltages V
DD1
, V
DD2
1.7 V to 5.5 V
Input Signal Rise and Fall Times 1.0 ms
3.0
2.5
2.0
1.5
0.5
1.0
0
020015010050
SAFE LIMITING POWER (W)
AMBIENT TEMPERATURE (°C)
13577-003
ADuM230D/ADuM230E/ADuM231D/ADuM231E Data Sheet
Rev. A | Page 12 of 21
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 16.
Parameter Rating
Storage Temperature (T
ST
) Range −65°C to +150°C
Ambient Operating Temperature
(T
A
) Range
−40°C to +125°C
Supply Voltages (V
DD1
, V
DD2
) −0.5 V to +7.0 V
Input Voltages (V
IA
, V
IB
, V
IC
, V
E1
, V
E2
,
DISABLE
1
, DISABLE
2
)
1
−0.5 V to V
DDI
+ 0.5 V
Output Voltages (V
OA
, V
OB
, V
OC
)
2
−0.5 V to V
DDO
+ 0.5 V
Average Output Current per Pin
3
Side 1 Output Current (I
O1
) −10 mA to +10 mA
Side 2 Output Current (I
O2
) −10 mA to +10 mA
Common-Mode Transients
4
−150 kV/s to +150 kV/s
1
V
DDI
is the input side supply voltage.
2
V
DDO
is the output side supply voltage.
3
See Figure 5 for the maximum rated current values for various ambient
temperatures.
4
Refers to the common-mode transients across the insulation barrier.
Common-mode transients exceeding the absolute maximum ratings may
cause latch-up or permanent damage.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Table 17. Maximum Continuous Working Voltage
1
RW-16
Wide Body [SOIC_W] Package
Parameter Rating Constraint
AC Voltage
Bipolar Waveform
Basic Insulation 849 V peak
50-year minimum
insulation lifetime
Reinforced Insulation 790 V peak
50-year minimum
insulation lifetime
Unipolar Waveform
Basic Insulation 1698 V peak
50-year minimum
insulation lifetime
Reinforced Insulation 849 V peak
50-year minimum
insulation lifetime
DC Voltage
Basic Insulation 1118 V peak
Lifetime limited by
package creepage
maximum approved
working voltage per
IEC 60950-1
Reinforced
Insulation
559 V peak
Lifetime limited by
package creepage
maximum approved
working voltage per
IEC 60950-1
1
Refers to the continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
Table 18. Maximum Continuous Working Voltage
1
RI-16 -2
Wide Body Increased Creepage [SOIC_IC] Package
Parameter Rating Constraint
AC Voltage
Bipolar Waveform
Basic Insulation 849 V peak
50-year minimum
insulation lifetime
Reinforced Insulation 819 V peak
Lifetime limited by
package creepage
maximum approved
working voltage per
IEC 60950-1
Unipolar Waveform
Basic Insulation 1698 V peak
50-year minimum
insulation lifetime
Reinforced Insulation 943 V peak
Lifetime limited by
package creepage
maximum approved
working voltage per
IEC 60950-1
DC Voltage
Basic Insulation 1157 V peak
Lifetime limited by
package creepage
maximum approved
working voltage per
IEC 60950-1
Reinforced Insulation 579 V peak
Lifetime limited by
package creepage
maximum approved
working voltage per
IEC 60950-1
1
Refers to the continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
ESD CAUTION

ADUM231E0BRWZ-RL

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators IC Robust 3 ch ISO 2:1 ch
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS