ICS525R-02I

OSCaR
TM
User Configurable Clock
MDS 525-01/02 R 7 Revision 021710
Integrated Device Technology, Inc. www.idt.com
ICS525-01/02
NOTE 1: Phase relationship between input and output can change at power-up. For a fixed phase
relationship, see the ICS527.
NOTE 2: For 16 MHz, 100 MHz output. Use the -02 for lowest jitter.
Output Clock Duty Cycle, OD =
2, 4, 6, 8, or 10
at VDD/2 45
49 to
51
55 %
Output Clock Duty Cycle, OD =
3, 5, 7, or 9
at VDD/2 40 60 %
Output Clock Duty Cycle, OD =
1 (-02 only)
at VDD/2 35 65
Power-down Time, PD low to
clocks stopped
50 ns
Power-up Time, PD high to
clocks stable
10 ms
Absolute Clock Period Jitter,
ICS525-01, Note 2
t
ja
Deviation from mean ±140 ps
One Sigma Clock Period Jitter,
ICS525-01, Note 2
t
js
One Sigma 45 ps
Absolute Clock Period Jitter,
ICS525-02, Note 2
t
ja
Deviation from mean ±85 ps
One Sigma Clock Period Jitter,
ICS525-02, Note 2
t
js
One Sigma 30 ps
Parameter Symbol Conditions Min. Typ. Max. Units
OSCaR
TM
User Configurable Clock
MDS 525-01/02 R 8 Revision 021710
Integrated Device Technology, Inc. www.idt.com
ICS525-01/02
Package Outline and Package Dimensions (28-pin SSOP, 150 mil Body)
Package dimensions are kept current with JEDEC Publication No. 95, MO-153
INDEX
AREA
1 2
28
D
E1
E
SEATING
PLANE
A
1
A
A
2
e
- C -
b
aaa C
c
L
*For reference only. Controlling dimensions in mm.
Millimeters Inches*
Symbol Min Max Min Max
A 1.351.75.053.069
A1 0.10 0.25 .0040 .010
A2 -- 1.50 -- .059
b 0.200.30.008.012
C 0.180.25.007.010
D 9.80 10.00 .386 .394
E 5.806.20.228.244
E1 3.80 4.00 .150 .157
e 0.635 Basic 0.025 Basic
L 0.401.27.016.050
α 0° 8° 0° 8°
aaa -- 0.10 -- 0.004
OSCaR
TM
User Configurable Clock
MDS 525-01/02 R 9 Revision 021710
Integrated Device Technology, Inc. www.idt.com
ICS525-01/02
Ordering Information
*NOTE: EOL for non-green parts to occur on 5/13/10 per PDN U-09-01
Parts that are ordered with a "LF" suffix to the part number are the Pb-Free configuration and are RoHS compliant.
While the information presented herein has been checked for both accuracy and reliability, Integrated Device Technology (IDT)
assumes no responsibility for either its use or for the infringement of any patents or other rights of third parties, which would
result from its use. No other circuits, patents, or licenses are implied. This product is intended for use in normal commercial
applications. Any other applications such as those requiring extended temperature range, high reliability, or other extraordinary
environmental requirements are not recommended without additional processing by IDT. IDT reserves the right to change any
circuitry or specifications without notice. IDT does not authorize or warrant any IDT product for use in life support devices or
critical medical instruments
Part / Order Number Marking Shipping Packaging Package Temperature
525-01R* ICS525-01R Tubes 28-pin SSOP 0 to +70° C
525-01RT* ICS525-01R Tape and Reel 28-pin SSOP 0 to +70° C
525-01RLF ICS525-01RLF Tubes 28-pin SSOP 0 to +70° C
525-01RLFT ICS525-01RLF Tape and Reel 28-pin SSOP 0 to +70° C
525-01RI* ICS525-01RI Tubes 28-pin SSOP -40 to +85° C
525-01RIT* ICS525-01RI Tape and Reel 28-pin SSOP -40 to +85° C
525-01RILF ICS525-01RILF Tubes 28-pin SSOP -40 to +85° C
525-01RILFT ICS525-01RILF Tape and Reel 28-pin SSOP -40 to +85° C
525R-02* ICS525R-02 Tubes 28-pin SSOP 0 to +70° C
525R-02T* ICS525R-02 Tape and Reel 28-pin SSOP 0 to +70° C
525R-02LF ICS525R-02LF Tubes 28-pin SSOP 0 to +70° C
525R-02LFT ICS525R-02LF Tape and Reel 28-pin SSOP 0 to +70° C
525R-02I* ICS525R-02I Tubes 28-pin SSOP -40 to +85° C
525R-02IT* ICS525R-02I Tape and Reel 28-pin SSOP -40 to +85° C
525R-02ILF ICS525R-02IL Tubes 28-pin SSOP -40 to +85° C
525R-02ILFT ICS525R-02IL Tape and Reel 28-pin SSOP -40 to +85° C

ICS525R-02I

Mfr. #:
Manufacturer:
Description:
IC CLOCK USER CONFIGURE 28-SSOP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union