E4B
E4B
7
E4B-LS70E4, E4B-RS70E4 E4B-T1E4
Variation rate of sensing distance (%)
Ambient temperature (°C)
Operating distance Y (cm)
V
R
:Max.
V
R
: Center
V
R
:Min.
Setti ng distance X (cm)
J AMBIENT TEMPERATURE VS.
VARIATION RATE OF SENSING
DISTANCE (TYPICAL)
J SENSITIVITY ADJUSTER POSITION
VS. PARALLEL MOVEMENT
CHARACTERISTICS
Installation
J INDICATORS
1. STABILITY Indicator (Green)
When this indicator is lit, the ultrasonic input into the Receiver is
sufficient, or i ts interruption i s small enough, to ensure the
smooth operation of the E4B. Do not operate the E4B when this
indicator is not lit.
2. SENSING Indi cator (Red)
When this indicator is lit, the Receiver has ultrasonic input.
J INDICATOR OF THROUGH-BEAM
EMITTER
1. Incident Indicator
Lit when ultrasonic signal detected.
To use this i ndicator of the Emitter as an SENSING indicator like
the i ndicator on the Recei ver, connect the black lead wires of the
Emitter and Receiver together.
Emitter
100 mA max.
Receiver
Load
Black
Blue
Brown
Blue
Brown
Black
+12to24V
0V
+12to24V
0V
Note: Be sure not to make mistakes in pol arity when connecting the above wi res. In other words, both brown lead wires must connect to
+VDC or 0 V and both blue l ead wires must connect to 0 V or +VDC . Otherwise, the indicator of the Emitter will be lit when the
ultrasonic beam is i nterrupted.
2. Power Indicator
Lit when the E4B i s turned ON .
If the above connections are not possible (e.g., the Receiver and
Emitter use different power supplies), this indicator will be used
as a pow er i ndicator.
Connections of Black (White) Lead Wire of Emitter
Pow er connection example
Brown: +VDC
Bl ue: 0 V
Brown: 0 V
Bl ue: +VDC
0 V blue
+VDC blue
Note: The indicator will not be lit if the above wires are not con-
nected correctly.