J BEAM AXIS, SE NSITIVITY, AND
DISTANCE ADJUSTME NTS
1. E4B-T1 and E4B-TS50 Through-beam Models
Set the SENSITIVITY adjuster of the Receiver to maximum.
Move the Emitter and Receiver vertically and horizontally until the
SENSING indicator of the Receiver is lit and secure the Emitter
and R eceiver at the midpoint of the range w ithin which the
STABILITY i ndicator is li t.
Optimum line
Range in which the STABILITY indicator (green) is lit
Range in which the SENSING indicator (red) is lit
Pass the sensing object through the sensi ng range and adjust
the sensitivity so that the SEN SING indicator turns ON and OFF
according to the presence or absence of the sensing object whil e
the STABILITY indicator i s lit continuousl y.
If the S TABILITY indicator i s not lit while the Sensor is in
operation, this may indicate a possibl e operati onal error. Check
or readjust the sensitivity.
If the E mitter and Receiver are set at a di stance shorter than the
rated sensing distance, reduce the sensitivity to within the range
in which the STABILITY indicator is lit. This will increase the
immunity of the Sensor against noise.
The parall el movement characteri stics (i.e., the mutual
interference distance) and sensing object size vary with the
sensitivity adjustment. Refer to Engineering Data and make the
optimum adjustments.
2. E4B-LS20 and E4B-LS70 Distance Setting Models
Locate the Sensor so that both the STABILITY and SENSING indicators will be lit when the object is placed at the sensing position, and
the STABILITY indicator will be lit and the SENSING indicator will turn OFF when the object is removed.
Step 1 2 3
Sensing
Sensing object
Background
Sensing object
Background
Sensing object
Background
Distance adjuster --- ---
Adj ustment
procedure
Pl ace the sensing object at the
sensing posi tion and turn the
distance adjuster clockwise
gradually until both the SEN SING
and STABILITY indicators are lit.
Rotate the sensor vertically and
horizontally and secure the sensor
at the midpoint of the range wi thin
which the STABILITY indicator i s on.
Remove the sensing object and
check that the SENS ING indi cator is
OFF and the STAB ILIT Y indicator is
continuously on.
Note: If the STABILIT Y indicator is not lit while the Sensor is in operation, this indicates a possible operational error. Check or readjust
the sensitivity.
E4B-LS20
The sensing distance is adj ustable within a range of 10 to 20 cm
with the distance adjuster.
Sensing
distance
Position of distance adjuster
5to10cm Set to the position 5-20. The distance range will
be5to23cminthiscaseduetothe
characteristics of the ultrasonic beam.
10 to 20 cm The adjuster can be set freely within a range of
10 to 20 cm. T he object can be detected within a
range of 5 to 10 cm in this case due to multiple
ultrasonic refl ection.
Setting sensing range (cm)
Sensing object
Unstable range
Separate them 30 cm min.
Background
E4B-LS20
E4B
E4B
9
3. E4B-RS70 Reflective Zone
Target Reflective
Locate the Sensor so that both the STABILITY and SENSING indicators will be lit when the sensing object is placed at the sensing posi-
tion and the STABILITY indicator will be lit and the SENSING indicator will be off when the sensing object is removed.
Step 1 2 3
Sensing
Sensing object
Background
Sensing object
Background
Sensing object
Background
Distance selector --- ---
Adj ustment
procedure
Pl ace the sensing object at the
sensing posi tion and turn the
distance selector clockw ise
gradually until both the SEN SING
and STABILITY indicators are lit.
Rotate the sensor vertically and
horizontally and secure the sensor
at the midpoint of the range wi thin
which the STABILITY indicator i s on.
Remove the sensing object and
check that the SENS ING indi cator is
OFF and the STAB ILIT Y indicator is
continuously on.
Note: 1. If the S TABILITY indicator i s not lit while the Sensor is in operation, this indicates a possibl e operati onal error. Check or readjust
the sensitivity.
2. If the background object is w ithin a distance of 1.5 m from the sensing head, the SENSING indicator may be lit and the STABILITY
indicator may not be lit in spite of the absence of the sensing object. Sensi tivi ty should be reduced until S TABILITY indicator turns
on. Re-check operati on with object present. If stable operation still does not occur, background may need to be relocated.
E4BE4B
10
Background Reflective
This method allow s the stable detection of objects under i rregular
and unstable reflection condi tions (e.g., if the sensing objects are
different in surface or size, if they are passed through diagonally,
or if they are sound absorbant).
The sensor is adj usted to detect the background, Acoustic
Reflector, rather than the target directly. When the target is
present, it blocks detection of the Acoustic Reflector.
Reflector
Sensing range (20 to 55 cm)
: Near the midpoint of the sensing range (e.g., 45, 55, or 65 cm)
E4B-RS70
The A coustic Reflector must be at least 4 x 4 cm in si ze and
made of a material that is efficiently reflective (such as a metal
plate).
Be sure that the target is not set within the sensing range.
Set the distance selector to the desired position, fi x the reflector
around the midpoint of the set sensing range, and check that
both the SEN SING and STABILITY indicators are lit.
Step 1 2 3
Sensing
Reflector
Set zone
Reflector
Reflector
Sensing object
Distance selector --- ---
Adj ustment
procedure
Set the distance selector to the
desired zone position, mount the
Reflector at or near the midpoint of
the set zone, and confirm that both
the STABILITY and SENSIN G
indicators are on.
Rotate the sensor vertically and
horizontally and secure the Emitter
and R eceiver at the midpoint of the
range within which the STABILITY
indicator is on.
Remove the sensing object and
check that the SENS ING indi cator is
OFF and the STAB ILIT Y indicator is
continuously on.
Note: 1. If the S TABILITY indicator i s not lit while the Sensor is in operation, this indicates a possibl e operati onal error. Check or readjust
the sensitivity.
2. If the object is in position A parallel to the R eflector as show n above, the SE NSING indicator may be lit and the STABILITY
indicator may not be lit depending on the position of the sensi ng object. In such a case, give priority to the adjustment of the
STABILITY i ndicator w hen the beam is inci dent by means of the reflector.