MAX8784
• Place V
CC
pin and REF pin bypass capacitors as
close as possible to the device. The ground con-
nection of the V
CC
bypass capacitor should be
connected directly to the AGND pin with a wide
trace.
• Minimize the length and maximize the width of the
traces between the output capacitors and the load
for best transient responses.
• Minimize the size of the LX node while keeping it
wide and short. Keep the LX and charge-pump
nodes away from feedback nodes (FB, FBP, and
FBN) and analog ground. Use DC traces as a
shield if necessary.
Refer to the MAX8784 evaluation kit for an example of
proper board layout.
Step-Up Regulator, Internal Charge Pumps, Switch
Control, and Operational Amplifier for TFT LCDs