3C35991FT0C

BCD.00060 Rev. AA July 07, 2011 Page 1 of 5 www.power-one.com
SLI 15 Inverter Series Data Sheet
1500 Watt, 1U Compact Inverters
Description
The SLI 15 Inverter Series provides an ideal solution for telecom, IT, and industrial applications. Due to innovative
technology solutions like the patent-pending "Compact Coil", the SLI 15 inverters pack 1500 watts of power into a
light (5.6 kg) and compact package that is mountable in 19" racks and is only one rack unit high. The SLI 15
Inverter Series offers four models for different input (24 and 48 VDC) and output (115 and 230 VAC) voltage
combinations. An integrated controller, along with an optional internal Static Transfer Switch (STS) enable flexible
and scalable systems which are truly "plug and play", and require no external subsystems. The inverters can be
stacked up to the power level needed by each application and also have the capability to be configured for
generating a 3-phase voltage source.
Electrical performance of the SLI 15 is exemplary of a top-of-the-market product with efficiency that peaks at 93%
and a patent-pending control algorithm that compensates current harmonics on the DC side without using bulky and
expensive filters. The SLI 15 includes a powerful on-board Digital Signal Processor (DSP) that allows easy
programming of main parameters through use of its front-panel keypad and LCD display. In addition, the SLI 15 can
be interfaced with an RS-485 serial communications link.
SLI Inverter Model Selection and Ordering Information
Model
1
Input Voltage
(VDC)
Output Voltage
Nominal
(VAC)
Overall Output
Voltage Range
(VAC)
Frequency
Range
(Hz)
SLI-24-115
24 115 100 to 120 47 to 63
SLI-24-230
24 230 200 to 240 47 to 63
SLI-48-115
48 115 100 to 120 47 to 63
SLI-48-230
48 230 200 to 240 47 to 63
1
The following suffixes should be added to the model number to order options. For an internal Static Transfer
Switch, please add the suffix "-STS". For AC terminal blocks, please add the suffix "-SC". For Hot Plug version,
please add the suffix “-HP”. For Neutral tied to Ground, please add the suffix “-GN”.
Applications
Telecom
IT
Industrial
Safety in compliance with IEC60950:1999, 3
rd
edition;
EN60950:2000; UL60950, 3
rd
edition; CSA Standard C22.2
No.60950-00, 3
rd
edition
Features
New, compact design: 1U height x 19" width
x 14.94" depth; 19" rack-mountable
High efficiency: up to 93%
True sine wave output
Parallelable output with current share and
synchronization of multiple inverters working
in parallel
Front panel LCD display to monitor and set
the main parameters
RS-485 serial link
Constant input current sink from battery for
extended life
Optional hot-swappable configuration
Optional internal Static Transfer Switch
In the -STS version, ON line (primary source
to the load) or OFF line mode (UPS like)
Configurable for being used as Three Phase
source, 3 units
BCD.00060 Rev. AA July 07, 2011 Page 2 of 5 www.power-one.com
SLI 15 Inverter Series Data Sheet
1500 Watt, 1U Compact Inverters
ELECTRICAL SPECIFICATIONS
Input Specifications
Parameter Conditions / Description Min. Nom. Max. Units
DC Input Voltage
Range
20
40
24
48
36
72
VDC
Input Current 24 VDC Models @ 18 VDC:
48 VDC Models @ 36 VDC:
100
48
Amps
Inrush current <10 Amps
Output Specifications
Parameter Conditions / Description Min. Nom. Max. Units
Output Power
1500 Watts
Output AC Voltage
Range
Standard is Vac floating from Ground; -GN
version is available with Neutral connected to
Ground (Grid Input shall be supplied by means
of an isolation transformer)
110
200
115
230
120
240
VAC
Frequency 50Hz/230Vac, 60Hz/115Vac 50 60 Hz
Efficiency
93 %
Load Power Factor lagging or leading 0,33 1
Crest Factor Ipk/Irms 4
Regulation in single
mode
Load: over full operating range. R-Load
Line: over full operating range. R-Load
-3
-0,1
+1
+0,1
%
Regulation in parallel
mode
Load: over full operating range. R-Load 230
115
-6
-8,5
0
0
%
Total Harmonic
Distortion
On Resistive Load. <2
%
BCD.00060 Rev. AA July 07, 2011 Page 3 of 5 www.power-one.com
SLI 15 Inverter Series Data Sheet
1500 Watt, 1U Compact Inverters
Fault Protection
Parameter Conditions / Description Min. Nom. Max. Units
Input Overcurrent
Protection
24 VDC Models; Internal Fuse.
48 VDC Models; Internal Fuse.
140
70
Amps
Input Overvoltage
Protection
24 VDC Models:
48 VDC Models:
37,5
74
VDC
Input Undervoltage
Protection
24 VDC Models:
48 VDC Models:
18
36
VDC
Output Overload 115 VAC Models:
230 VAC Models:
1610
1840
W
Surge 115 VAC Models for 200 ms:
230 VAC Models for 200 ms:
1750
2300
VA
Overvoltage Protection
All outputs are set at 115%, ±2 % of nominal.
Undervoltage
Protection
All outputs are set at 85%, ±2 % of nominal.
Overcurrent Protection 115 VAC Models: 1 A to 14 A selectable.
230 VAC Models: 1 A to 8 A selectable.
Safety Overcurrent
Protection
By safety circuit breaker:
115 VAC Models: 15 A.
230 VAC Models: 10 A.
Short-Circuit
Protection
Peak Current type protection:
115 VAC Models: 60 A.
230 VAC Models: 30 A.
Overtemperature
Protection
Visual and acoustic indication 5 C before shutdown at T
amb
> 65 C and at T
int
> 100 C.
Protection Restore
Modes
The restore mode of each protection can be individually selected to "latch" or "auto-restart".
Environmental Specifications
Parameter Conditions / Description Min. Nom. Max. Units
Operating Temp
at Full Load
Power Derating: 75W/ºC: +55 ºC to +65 ºC. -25 55
ºC
Altitude Operating.
Non-Operating.
13K
40K
ASL ft
ASL ft
Storage Temp -40 85 ºC
Humidity 90% relative humidity @ 40 ºC, non-condensing.
Output Voltage
Temperature
Coefficient
0.02% per ºC within rated load.

3C35991FT0C

Mfr. #:
Manufacturer:
Bel Power Solutions
Description:
Power Conditioning 1500W 48VIN 230VOUT
Lifecycle: