74LVC1G86GV-Q100H

Nexperia
74LVC1G86-Q100
2-input EXCLUSIVE-OR gate
74LVC1G86_Q100 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 3 — 7 March 2017
4 / 13
9 Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter Conditions Min Typ Max Unit
V
CC
supply voltage 1.65 - 5.5 V
V
I
input voltage 0 - 5.5 V
Active mode 0 - V
CC
VV
O
output voltage
V
CC
= 0 V; Power-down mode 0 - 5.5 V
T
amb
ambient temperature -40 - +125 °C
V
CC
= 1.65 V to 2.7 V - - 20 ns/VΔt/ΔV input transition rise and fall rate
V
CC
= 2.7 V to 5.5 V - - 10 ns/V
10 Static characteristics
Table 7. Static characteristics
At recommended operating conditions. Voltages are referenced to GND (ground = 0 V).
-40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max
Unit
V
CC
= 1.65 V to 1.95 V 0.65V
CC
- - 0.65V
CC
- V
V
CC
= 2.3 V to 2.7 V 1.7 - - 1.7 - V
V
CC
= 2.7 V to 3.6 V 2.0 - - 2.0 - V
V
IH
HIGH-level input
voltage
V
CC
= 4.5 V to 5.5 V 0.7V
CC
- - 0.7V
CC
- V
V
CC
= 1.65 V to 1.95 V - - 0.35V
CC
- 0.35V
CC
V
V
CC
= 2.3 V to 2.7 V - - 0.7 - 0.7 V
V
CC
= 2.7 V to 3.6 V - - 0.8 - 0.8 V
V
IL
LOW-level input
voltage
V
CC
= 4.5 V to 5.5 V - - 0.3V
CC
- 0.3V
CC
V
V
I
= V
IH
or V
IL
I
O
= -100 μA;
V
CC
= 1.65 V to 5.5 V
V
CC
- 0.1 - - V
CC
- 0.1 - V
I
O
= -4 mA; V
CC
= 1.65 V 1.2 - - 0.95 - V
I
O
= -8 mA; V
CC
= 2.3 V 1.9 - - 1.7 - V
I
O
= -12 mA; V
CC
= 2.7 V 2.2 - - 1.9 - V
I
O
= -24 mA; V
CC
= 3.0 V 2.3 - - 2.0 - V
V
OH
HIGH-level
output voltage
I
O
= -32 mA; V
CC
= 4.5 V 3.8 - - 3.4 - V
V
I
= V
IH
or V
IL
I
O
= 100 μA;
V
CC
= 1.65 V to 5.5 V
- - 0.10 - 0.10 V
I
O
= 4 mA; V
CC
= 1.65 V - - 0.45 - 0.70 V
I
O
= 8 mA; V
CC
= 2.3 V - - 0.30 - 0.45 V
V
OL
LOW-level output
voltage
I
O
= 12 mA; V
CC
= 2.7 V - - 0.40 - 0.60 V
Nexperia
74LVC1G86-Q100
2-input EXCLUSIVE-OR gate
74LVC1G86_Q100 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 3 — 7 March 2017
5 / 13
-40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max
Unit
I
O
= 24 mA; V
CC
= 3.0 V - - 0.55 - 0.80 V
I
O
= 32 mA; V
CC
= 4.5 V - - 0.55 - 0.80 V
I
I
input leakage
current
V
I
= 5.5 V or GND;
V
CC
= 0 V to 5.5 V
- ±0.1 ±1 - ±1 μA
I
OFF
power-off
leakage current
V
CC
= 0 V; V
I
or V
O
= 5.5 V - ±0.1 ±2 - ±2 μA
I
CC
supply current V
I
= 5.5 V or GND; I
O
= 0 A;
V
CC
= 1.65 V to 5.5 V
- 0.1 4 - 4 μA
ΔI
CC
additional supply
current
per pin; V
CC
= 2.3 V to 5.5 V;
V
I
= V
CC
- 0.6 V; I
O
= 0 A
- 5 500 - 500 μA
C
I
input
capacitance
V
CC
= 3.3 V; V
I
= GND to V
CC
- 5 - - - pF
[1] All typical values are measured at V
CC
= 3.3 V and T
amb
= 25 °C.
11 Dynamic characteristics
Table 8. Dynamic characteristics
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 6.
-40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max
Unit
A, B to Y; see Figure 5
[2]
V
CC
= 1.65 V to 1.95 V 1.0 3.7 9.9 1.0 13.0 ns
V
CC
= 2.3 V to 2.7 V 0.5 2.5 5.5 0.5 7.0 ns
V
CC
= 2.7 V 0.5 2.8 5.8 0.5 7.5 ns
V
CC
= 3.0 V to 3.6 V 0.5 2.3 5.0 0.5 6.5 ns
t
pd
propagation delay
V
CC
= 4.5 V to 5.5 V 0.5 1.9 4.0 0.5 5.5 ns
V
I
= GND to V
CC
[3]
C
PD
power dissipation
capacitance
V
CC
= 3.3 V - 25 - - - pF
[1] All typical values are measured at nominal V
CC
.
[2] t
pd
is the same as t
PLH
and t
PHL
[3] C
PD
is used to determine the dynamic power dissipation (P
D
in μW).
P
D
= C
PD
× V
CC
2
× f
i
× N + Σ(C
L
× V
CC
2
× f
o
) where:
f
i
= input frequency in MHz;
f
o
= output frequency in MHz;
C
L
= output load capacitance in pF;
V
CC
= supply voltage in V;
N = number of inputs switching;
Σ(C
L
× V
CC
2
× f
o
) = sum of the outputs.
Nexperia
74LVC1G86-Q100
2-input EXCLUSIVE-OR gate
74LVC1G86_Q100 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 3 — 7 March 2017
6 / 13
11.1 Waveforms and test circuit
mna041
t
PHL
t
PLH
V
M
V
M
A, B input
Y output
Measurement points are given in Table 9.
V
OL
and V
OH
are typical output voltage levels that occur with the output.
Figure 5. The input A and B to output Y propagation delay times
Table 9. Measurement points
Supply voltage Input Output
V
CC
V
M
V
M
1.65 V to 1.95 V 0.5V
CC
0.5V
CC
2.3 V to 2.7 V 0.5V
CC
0.5V
CC
2.7 V 1.5 V 1.5 V
3.0 V to 3.6 V 1.5 V 1.5 V