Nexperia
74LVC1G86-Q100
2-input EXCLUSIVE-OR gate
74LVC1G86_Q100 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 3 — 7 March 2017
7 / 13
V
EXT
V
CC
V
I
V
O
mna616
DUT
C
L
R
T
R
L
R
L
G
Test data is given in Table 10.
Definitions test circuit:
R
T
= Termination resistance should be equal to output impedance Z
o
of the pulse generator.
C
L
= Load capacitance including jig and probe capacitance.
R
L
= Load resistance.
V
EXT
= External voltage for measuring switching times.
Figure 6. Test circuit for measuring switching times
Table 10. Test data
Supply voltage Input Load V
EXT
V
CC
V
I
t
r
= t
f
C
L
R
L
t
PLH
, t
PHL
1.65 V to 1.95 V V
CC
≤ 2.0 ns 30 pF 1 kΩ open
2.3 V to 2.7 V V
CC
≤ 2.0 ns 30 pF 500 Ω open
2.7 V 2.7 V ≤ 2.5 ns 50 pF 500 Ω open
3.0 V to 3.6 V 2.7 V ≤ 2.5 ns 50 pF 500 Ω open
4.5 V to 5.5 V V
CC
≤ 2.5 ns 50 pF 500 Ω open