SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 10 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
EAS and AFI password protection is disabled
Status of EAS mode is not defined
AFI is supported and not defined
DSFID is supported and not defined
User data memory is not defined
Remark: Because the EAS mode is undefined at delivery, the EAS mode shall be set
(enabled or disabled) according to your application requirements during the test or
initialization phase.
Remark: If password protection is not required, depending on the targeted application, it
is recommended to write random passwords during the label initialization.
8.3 Communication principle
For detailed description of the protocol and timing please refer to ISO/IEC 15693-2
(modulation, bit-coding, framing, Ref. 2
) and ISO/IEC 15693-3 (anticollision, timing,
protocol, Ref. 3
).
8.4 Supported commands
8.4.1 Mandatory commands
8.4.1.1 INVENTORY
As defined in ISO/IEC 15693-3.
Exception: If the Privacy or Destroy mode is enabled the label will not respond.
8.4.1.2 STAY QUIET
As defined in ISO/IEC 15693-3.
8.4.2 Optional commands
8.4.2.1 READ SINGLE BLOCK
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
If the related page of the addressed block is protected with the Read-Password and the
password has not been transmitted first with the SET PASSWORD command the label will
respond according to the error handling (see Section 8.5 “
Error handling).
8.4.2.2 WRITE SINGLE BLOCK
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 11 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
If the addressed block is part of a write protected page or only protected with the Read
Password (see Section 8.4.3.6 “
PROTECT PAGE) and the password has not been
transmitted first with the SET PASSWORD command the label will respond according to
the error handling (see Section 8.5 “
Error handling).
8.4.2.3 LOCK BLOCK
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
If the addressed block is part of a write protected page or only protected with the read
password (see Section 8.4.3.6 “
PROTECT PAGE) and the password has not been
transmitted first with the SET PASSWORD command, the label will respond according to
the error handling (see Section 8.5 “
Error handling).
8.4.2.4 SELECT
As defined in ISO/IEC 15693-3.
8.4.2.5 RESET TO READY
As defined in ISO/IEC 15693-3.
8.4.2.6 WRITE AFI
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Remark: This command maybe password protected, refer to Section 8.4.3.17
PASSWORD PROTECT EAS/AFI.
8.4.2.7 LOCK AFI
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Remark: This command maybe password protected, refer to Section 8.4.3.17
PASSWORD PROTECT EAS/AFI.
8.4.2.8 WRITE DSFID
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
8.4.2.9 LOCK DSFID
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 12 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
Option 1 (Option flag set) is supported.
8.4.2.10 GET SYSTEM INFORMATION
As defined in ISO/IEC 15693-3.
The TAG type of the ICODE SLIX-S IC is “02h”.
8.4.3 Custom commands
The manufacturer code of NXP Semiconductors is defined in ISO/IEC 7816-6A1 (Ref. 5).
It has the value “04h”.
For the structure of custom commands please refer to ISO/IEC 15693-3.
If not explicitly specified differently all address modes are supported.
8.4.3.1 GET RANDOM NUMBER
Command code = B2h
The GET RANDOM NUMBER command is required to receive a random number from the
label IC. The passwords that will be transmitted with the SET PASSWORD command
have to be calculated with the password and the random number (see Section 8.4.3.2
SET PASSWORD).
The different passwords are addressed with the password identifier.
8.4.3.2 SET PASSWORD
Command code = B3h
The SET PASSWORD command enables the different passwords to be transmitted to the
label to access the different protected functionalities of the following commands. The SET
PASSWORD command has to be executed just once for the related passwords if the label
is powered.
Remark: The SET PASSWORD command can only be executed in Addressed or
Selected mode except for the Privacy password. If the Privacy password is transmitted
(see Section 8.4.3.10 “
ENABLE PRIVACY), the timing of the SET PASSWORD
command is write alike.
Table 6. Request format
SOF Flags GET
RANDOM
NUMBER
IC Mfg
code
UID CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
16 bits -
Table 7. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 8. Response format when Error_flag NOT set
SOF Flags Random number CRC16 EOF
- 8 bits 16 bits 16 bits -

SL2S5302FUD,003

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
RFID Transponders ICODE SLIX-S
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet