MS46-30-1215-Q1-X-TK1

Rev. 6.13
Safety Light Curtains
MS4600
MS4600
For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
D1
D
www.sti.com/info
MiniSafe
®
Light Curtains
• Resolution:14mm(0.55in.),19mm(0.75in.)or30mm(1.18in.)resolution
• Range:7.5m(25ft.)rangeforthe14mmresolution,20m(65ft.)rangeforthe
19and30mmresolutions
• ProtectedHeights:14mmand19mmresolutionsfrom263to1393mm(10to
55in.);or30mmresolutionfrom351to2095mm(14to83in.)
• Compactsize—35x50mm(1.4x2in.)
• Nocablerequiredbetweentransmitterandreceiver
• IndividualBeamIndicators
FileNo.LR90200
R
C US
C US
Specifications for Transmitter and Receiver
Performance
ProtectedHeight: 14and19mm— 263to1393mmin86mmincrements
(10.3to54.5inchesin3.4inchincrements)
30mm— 350to2090mm(13.8to82.6in.)
OperatingRange MS46SR: 0.3to7.5m(1to25ft.)for14mmresolution
0.3to9m(1to30ft.)for19mmand30mmresolutions
MS46LR: 0.3to20m(1to65ft.)/Notavailablewith14mmresolution
Resolution: 14mm(0.55in.),19mm(0.75in.)or30mm(1.18in.).UseofExactChannelSelect
and/orFloatingBlankingmayincreasethisvalue.
ResponseTime(varies
byprotectedheight):
Seetablesatright
InputVoltage(V
in
): 24VDC±20%
InputPower: 14watts(withoutloadontheoutputs)
SafetyOutputRatings: TwoPNPoutputssourcing500mAmax@V
in
(seenote1).Shortcircuitprotected.
Auxiliary(Non-Safety)
OutputRatings:
OneNPNoutputsinking100mAmax@V
in
oronePNPoutputsourcing100mA@V
in
(seenotes1and2)
PowerSupply: 24VDC±20%.Theratingdependsonthecurrentrequirementsoftheloads
attachedtotheoutputs(seenote3).Thepowersupplymustmeettherequirements
ofIEC60204-1and61496-1.STIpartnumber42992orequivalent.
MPCEMonitoringCircuit: 50mAsteadystate@24VDC
Start/RestartInput: N.C.orN.O.momentarycontact(20mAconsumption)
EffectiveApertureAngle: ±2.5°maximum,transmitterandreceiveratoperatingrangegreaterthan3m(9.8ft.).
LightSource: GaAlAsLightEmittingDiode,850nm
Indicators Transmitter:Powerapplied(Yellow)
Receiver:MachineStop(Red),MachineRun(Green),
InterlockorAlarmIndicator(Yellow),BlankingIndicator(Amber)
Mechanical
Enclosure: Polyurethanepowder-paintedaluminum
CableLength: Optionalcablesareavailablein10,15,30and50mlengths
CableConnections
(M12):
Receiver:8-pin
Transmitter:3-pinstandard,5-pinwithMTS
Environmental
ProtectionRating: NEMA4,12;IP65
OperatingTemperature: 0to55°C(32to131°F)
RelativeHumidity: 95%maximum,non-condensing
Vibration: 5-60Hzmaximumonallthreeaxis
Shock: 10gfor0.016seconds,1,000shocksforeachaxisontwoaxis
Approvals
ESPEType4(IEC61496-1/-2)
Category4/PLe(ENISO13849-1)
SIL3/SIL3CL3(IEC61508/EN62061)
UL508,UL1998,CAN/CSA-C22.2No.14,CAN/CSA-C22.2No.0.8,
CAN/CSA-C22.2No0,CAN/CSA-C22.2No205
Specicationsaresubjecttochangewithoutnotice.
Note1:VoltageavailableattheoutputsisequaltoV
in
-2.0VDC.
Note2:Totalcurrentrequiredbythetwosolid-stateoutputsandtheaux.outputshouldnotexceed1.1A.
Note3:Totalsystemcurrentrequirementisthesumofthetransmitter285mAandreceiver1.4Amax.(Receiver
300mA+OSSD1load+OSSD2load+Aux.outputload)
Response Times for Systems
with 14 mm and 20 mm
Resolutions
Protected
Height
(mm/in.)
No. of
Beams
Response
Time
(seconds)
263/10.4 24 <0.016
350/13.8 32 <0.017
437/17.2 40 <0.019
524/20.6 48 <0.021
611/24.1 56 <0.023
698/27.5 64 <0.025
785/30.9 72 <0.027
872/34.3 80 <0.031
959/37.7 88 <0.033
1046/41.2 96 <0.035
1133/44.6 104 <0.035
1220/48.0 112 <0.037
1306/51.4 120 <0.039
1393/54.9 128 <0.040
Response Times for Systems
with 30 mm Resolutions
Protected
Height
(mm/in.)
No. of
Beams
Response
Time
(seconds)
350/13.8 16 <0.014
524/20.6 24 <0.016
698/27.5 32 <0.017
872/34.3 40 <0.019
1046/41.2 48 <0.021
1220/48.0 56 <0.023
1393/54.9 64 <0.025
1570/61.8 72 <0.027
1741/68.6 80 <0.029
1915/75.4 88 <0.031
2090/82.3 96 <0.033
D2
D
www.sti.com/info
MS4600 Safety Light Curtains
Wiring
ID Components & Indicators
1 Receiver
2 IndividualBeamIndicators(oneforeachbeam)—Red
3 RemovableEndCap,Accesstocongurationswitches
4 ProgramButton(mustremovesecurityscrew)
5 ChannelSelectorFloatingBlankingIndicator—Amber
6 InterlockorAlarmIndicator—Yellow
7 MachineStopIndicator—Red
8 MachineRunIndicator—Green
6 ReceiverConnections
I Start—GreyWire
J OSSD2—YellowWire
C OSSD1—GreenorOrangeWire
D 0VDC—BrownWire
E Drain—UninsulatedWire
F +24VDC—WhiteWire
G AuxiliaryOut—BlueorVioletWire
H MPCE—PinkWire
10 InsideReceiverEndCap
A SwitchA
B SwitchB
K Connector
System Configuration
12
RECEIVER
1
2
TRANSMITTER
INDICATOR SIDE
11
14
I
9
J
N
C
G
F
E
M
D
H
L
4600 System
4600 System
3
Status
K
6
7
4
8
5
10
13
16
O
56
4321
ON ON
65
4321
INSIDE RCVR
ENDCAP
B
A
P
Program
Stop
Run
Interlock
FB or CS
15
M
N
L
Non-MTS Transmitter
MTS Transmitter
1 2
5 6
3 4
1 2 3 4
6
5
Automatic Start
Start Interlock
Start/Restart Interlock
MPCE Inactive
MPCE Active
Exact Channel Select Inactive
Exact Channel Select Active
Floating Blanking Inactive
1 Channel Floating Blanking Active
2 Channel Floating Blacking Active
*
Shown in Factory Default Settings
On
On
On
Off
On
On
On
On
*
*
*
*
Off
Off
Off
Off
Off
Off
Off
Off
Receiver DIP Switch Settings
On
On
OP Mode
OP Mode
MPCE
CH Select
FB1
FB2
OP Mode
OP Mode
MPCE
CH Select
FB1
FB2
ON
ON
SWA
SWB
1234 56
Switch B
Switch A
ID Components & Indicators
11 Transmitter
12 StatusIndicator—Yellow
13 TransmitterConnections(withoutMachineTestSignal)
L Drain—UninsulatedWire
M +24VDC—WhiteWire
N 0VDC—BrownWire
14 SynchronizationBeam
15 DetectionZone
16 TransmitterConnections(withMachineTestSignal)
L Drain—UninsulatedWire
M +24VDC—WhiteWire
N 0VDC—BrownWire
O MTS—BlueWire
P MTSReturn—BlackWire
D3
D
www.sti.com/info
Wiring (continued)
1
EDM (External Device Monitoring) must be used
when force-guided control relays are used as the
Final Switching Devices. Connect the the Pink
wire though N/C contacts to 0 VDC.
For the purpose of bench testing prior to installation,
the user may select EDM OFF (default factory
setting). In this case the EDM line (pink wire) must
be connected to the system 0 VDC line.
Auxilary Output connect to PLC (optional)
User-supplied fuse 50 VA
If remote start is not used, connect the start line
(gray wire) to 0 VDC.
2
3
4
5
Start
OSSD 1
OSSD 2
0VDC
Shield
+24VDC
Aux.
Output
MPCE
Mon.
+24VDC
0 VDC
GRAY
DRAIN
BROWN
WHITE
4600 Receiver
Shield
4600 Transmitter
+24VDC
0VDC
DRAIN
WHITE
BROWN
START
PINK
Earth
Ground
ED2
Power Supply
2
3
4
5
ED1
ED2
ED1
Shielded Cable
Shielded Cable
Shielded Cable
1
For transmitter with MTS option
Blue
Black
ORANGE
OR
GREEN
YELLOW
VIOLET
OR
BLUE
To Machine Control Contacts
ED1 ED2
Using Solid-state Outputs
Connecting Via Two Force-Guided Relays
FGRseriesrelaysprovideforce-guidedoutputsformachinecontrol.
MS4600 Safety Light Curtains

MS46-30-1215-Q1-X-TK1

Mfr. #:
Manufacturer:
Description:
SPARE TRANSMITTER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet