2701531

https://www.phoenixcontact.com/pi/products/2701531
08/20/2018Page1/6
Distributed I/O device-AXL E EC IOL8 DI4 M12 6M-2701531
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
AxiolineE-EtherCAT
®
device in a metal housing with 8IO-Link ports and 4digital inputs, 24VDC, M12 fast
connection technology
Product Description
The Axioline E device is designed for use within an EtherCAT
®
network.
It enables the operation of up to eight IO-Link sensors/actuators and is also used to acquire digital signals.
Why buy this product
Connection to EtherCAT® network using M12connectors (D-coded)
Transmission speed of 100 Mbps
Connection of four IO-Link devices with additional digital input
Connection of four IO-Link actuators with additional power supply
Connection of IO-Link ports using M12connectors (A-coded, 5-pos.)
Diagnostic and status indicators
Short-circuit and overload protection of the sensor supply
IP65/IP67 degree of protection
Key Commercial Data
Packing unit 1 STK
GTIN
GTIN 4046356763790
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width 60 mm
Height 185 mm
Depth 38 mm
https://www.phoenixcontact.com/pi/products/2701531
08/20/2018Page2/6
Distributed I/O device-AXL E EC IOL8 DI4 M12 6M-2701531
Technical data
Dimensions
Note on dimensions
The height is 194.5 mm including the mounting plate. With fixing clips
pulled out, the height is 212 mm. The depth is 38 mm including the
mounting plate (30.5 mm without the mounting plate).
Drill hole spacing 198.5 mm
Ambient conditions
Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 %
Permissible humidity (storage/transport) 5 % ... 95 %
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000m above sea level)
Degree of protection IP65/IP67
General
Housing material Zinc die-cast
Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
Net weight 726.9 g
Interfaces
Designation
EtherCAT
®
No. of channels 2
Connection method M12 fast connection technology
Note on the connection method D-coded
Designation connection point Copper cable
Transmission speed 100 Mbps (with auto negotiation)
Number of positions 4
System limits of the bus coupler
Designation
EtherCAT
®
Equipment type
EtherCAT
®
slave
System-specific protocols
Mailbox protocols CANopen
®
over EtherCAT
®
Mailbox protocols File access over EtherCAT
®
Type of addressing Auto-increment addressing
Fixed position addressing
Logical addressing
Specification ETG.1000 V1.02
Supply
Designation
Module electronics and sensors (U
S
)
Connection method M12 connector (T-coded)
Number of positions 4
Supply voltage 24 V DC
https://www.phoenixcontact.com/pi/products/2701531
08/20/2018Page3/6
Distributed I/O device-AXL E EC IOL8 DI4 M12 6M-2701531
Technical data
Supply
Nominal supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumption max. 12 A
Typical current consumption 180 mA ±15 % (at 24 V DC)
Designation
Actuators (U
A
)
Connection method M12 connector (T-coded)
Number of positions 4
Supply voltage 24 V DC
Nominal supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumption max. 12 A
Typical current consumption 28 mA ±15 % (at 24 V DC)
Digital inputs
Description of the input IO-Link ports in digital input (DI) mode
Connection method M12 connector, X01 ... X04 have double occupancy
Connection technology 3-wire
Nominal input voltage U
IN
24 V DC
Input voltage range "0" signal -0.3 V DC ... 5 V DC
Input voltage range "1" signal 15 V DC ... 30 V DC
Nominal input current typ. 3 mA
Sensor current per channel max. 200 mA (from L+/L-)
Total sensor current max. 1.6 A (from L+/L-)
Input filter time < 1000 µs
Input frequency 0.5 kHz
Type of protection Overload protection
Short-circuit protection for the sensor supply
Digital outputs
Output description IO-Link ports in digital output (DO) mode
Connection method M12 connector, X01 ... X04 have double occupancy
Connection technology 3-wire
Number of outputs max. 8
Nominal output voltage 24 V DC
Maximum output current per channel 150 mA
Maximum output current per device 1.2 A
Nominal load, ohmic 3.6 W (160 Ω, at nominal load)
Nominal load, inductive 3.6 VA (0.8 H, 160 Ω, at nominal load)
Signal delay max. 150 µs (when switched on)
max. 200 µs (when switched off)
Switching rate 1 per second, maximum (at nominal inductive load)
Limitation of the voltage induced on circuit interruption -15 V DC
Output voltage when switched off max. 1 V
Output current when switched off max. 300 µA

2701531