www.murata-ps.com/support
LSM2 Series
Single Output, Non-Isolated
Selectable-Output POL DC/DC Converters
MDC_LSM2 Series.D01∆ Page 3 of 17
Performance/Functional Specifications
(1)
INPUT
Input Voltage Range See Ordering Guide
Isolation Not isolated, input and output use the same
common return.
Start-Up Threshold
W3 Models 2.2 Volts
12V Models 8 Volts
Undervoltage Shutdown
W3 Models 2.0 Volts
12V Models 7.5 Volts
Overvoltage Shutdown None
Reflected (Back) Ripple Current
(2)
20-70mAp-p (model dependent)
Internal Input Filter Type Capacitive
Reverse Polarity Protection See fuse information
Input Current:
Full Load Conditions See Ordering Guide
Inrush Transient 0.1-0.4A
2
sec (model dependent)
Shutdown Mode (Off, UV, OT) 5mA
Output Short Circuit 60mA
Low Line (VIN = VMIN)
LSM2-T/6-W3 5.54 Amps
LSM2-T/6-D12 3.79 Amps
LSM2-T/10-W3 9.14 Amps
LSM2-T/10-D12 6.375 Amps
LSM2-T/16-W3 14.63 Amps
LSM2-T/16-D12 10.2 Amps
Remote On/Off Control:
(5)
Positive Logic (no model suffix) OFF = ground pin to +0.3V max.
ON = open pin or +VIN max.
Negative Logic (“N” model suffix) ON = Open pin or 0 to +0.3V max.
OFF = +2.5V to +VIN max.
Current 1mA max.
OUTPUT
Voltage Output Range See Ordering Guide
Minimum Loading No minimum load
Accuracy (50% load) ±2% of VNOM
Voltage Adjustment Range
(13)
See Ordering Guide
Temperature Coefficient ±0.02% of VOUT range per °C
Ripple/Noise (20 MHz bandwidth) See Ordering Guide and
(8)
Line/Load Regulation (See Tech Notes) See Ordering Guide and
(10)
Efficiency See Ordering Guide
Maximum Capacitive Loading:
(14)
LSM2-T/6 models:
Cap-ESR = 0.001 to 0.01W 3000µF
Cap-ESR >0.01W 5000µF
LSM2-T/10 and -T/16 models:
Cap-ESR = 0.001 to 0.01W 5000µF
Cap-ESR >0.01W 10,000µF
Current Limit Inception: (98% of VOUT)
LSM2-T/6 models 10 Amps (after warm up)
LSM2-T/10 models 16.75 Amps (after warm startup)
LSM2-T/16 models 21–31 Amps (after warm up)
Short Circuit Mode
(6)
Short Circuit Current Output 600mA
Protection Method
(16)
Hiccup autorecovery on overload removal
Short Circuit Duration Continuous, no damage (output shorted to
ground)
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous or transient)
W3 models +7 Volts
12V models +15 Volts
On/Off Control –0.3V min. to +VIN max.
Input Reverse Polarity Protection See Fuse section
Output Current (7) Current-limited. Devices can
withstand sustained short circuit
without damage.
Storage Temperature –55 to +125°C
Lead Temperature (soldering 10 sec. max.) +280°C
These are stress ratings. Exposure of devices to greater than any of these conditions may
adversely affect long-term reliability. Proper operation under conditions other than those listed in
the Performance/Functional Specifications Table is not implied.
Pre-bias Startup
(15)
Converter will start up if the external
output voltage is less than VNOM
Sequencing
Slew Rate 2V max. per millisecond
Startup delay until sequence start 10 milliseconds
Tracking accuracy, rising input VOUT = ±100mV of Sequence In
Tracking accuracy, falling input VOUT = ±200mV of Sequence In
Sequence pin input impedance 400kW to 1MW
Remote Sense to VOUT 0.5V max.
(7)
Power Good Output
(17)
TRUE (OK) = open drain
(“G” suffix) FALSE (not OK) = Signal Ground to 0.4V
Power_Good Configuration MOSFET to ground with external user
pullup, 10mA max. sink
DYNAMIC CHARACTERISTICS
Dynamic Load Response 25µsec to ±2% of final value
(50-100-50% load step, di/dt = 20A/µsec)
Start-Up Time 7msec for VOUT = nominal
(VIN on to VOUT regulated or On/Off to VOUT)
Switching Frequency
LSM2-T/6 models 315kHz
LSM2-T/10 and -T/16 models 230kHz
ENVIRONMENTAL
Calculated MTBF
(4)
TBC Hours
Operating Temperature Range (Ambient) –40 to +85°C
with derating
(9)
See Derating Curves
Operating PC Board TemUperature –40 to +100°C max.
(12)
Storage Temperature Range –55 to +125°C
Thermal Protection/Shutdown +115°C
Relative Humidity to 85% / +85°C, non-condensing
PHYSICAL
Outline Dimensions See Mechanical Specifications
Removable Heat Shield Nylon 46
Weight 0.28 ounces (7.8 grams)
Lead Material Tin-plated copper alloy
Electromagnetic Interference
Designed to meet
FCC part 15, class B,
EN55022
(conducted and radiated) (may need external filter)
Safety Designed to meet UL/cUL 60950-1 CSA-
C22.2 No.234 IEC/EN
60950-1
Flammability UL94V-0