Symbol Test Conditions Characteristic Values
(T
J
= 25°C Unless Otherwise Specified) Min. Typ. Max.
g
fs
I
C
= 60A, V
CE
= 10V, Note 1 30 55 S
C
ies
4740 pF
C
oes
V
CE
= 25V, V
GE
= 0V, f = 1MHz 470 pF
C
res
103 pF
Q
g(on)
168 nC
Q
ge
I
C
= 100A, V
GE
= 15V, V
CE
= 0.5 • V
CES
30 nC
Q
gc
78 nC
t
d(on)
29 ns
t
ri
37 ns
E
on
1.27 mJ
t
d(off)
150 ns
t
fi
73 ns
E
off
1.37 2.00 mJ
t
d(on)
28 ns
t
ri
37 ns
E
on
2.35 mJ
t
d(off)
198 ns
t
fi
160 ns
E
off
2.16 mJ
R
thJC
0.18 °C/W
R
thCS
0.15 °C/W
Notes:
1. Pulse test, t 300μs, duty cycle, d 2%.
2. Switching times & energy losses may increase for higher V
CE
(clamp), T
J
or R
G
.
Inductive load, T
J
= 150°C
I
C
= 50A, V
GE
= 15V
V
CE
= 400V, R
G
= 3
Note 2
Reverse Diode (FRED)
Symbol Test Conditions Characteristic Values
(T
J
= 25°C Unless Otherwise Specified) Min. Typ. Max.
V
F
I
F
= 100A, V
GE
= 0V, Note 1 1.7 2.7 V
T
J
= 150C 1.4 V
I
RM
45 A
t
rr
156 ns
R
thJC
0.36 C/W
I
F
= 100A, V
GE
= 0V, T
J
= 150C,
-di
F
/dt = 700A/sV
R
= 400V
Inductive load, T
J
= 25°C
I
C
= 50A, V
GE
= 15V
V
CE
= 400V, R
G
= 3
Note 2
TO-264 Outline
Terminals: 1 = Gate
2,4 = Collector
3 = Emitter
Terminals: 1 - Gate
2 - Collector
3 - Emitter
PLUS247
TM
Outline
Dim. Millimeter Inches
Min. Max. Min. Max.
A 4.83 5.21 .190 .205
A
1
2.29 2.54 .090 .100
A
2
1.91 2.16 .075 .085
b 1.14 1.40 .045 .055
b
1
1.91 2.13 .075 .084
b
2
2.92 3.12 .115 .123
C 0.61 0.80 .024 .031
D 20.80 21.34 .819 .840
E 15.75 16.13 .620 .635
e 5.45 BSC .215 BSC
L 19.81 20.32 .780 .800
L1 3.81 4.32 .150 .170
Q 5.59 6.20 .220 0.244
R 4.32 4.83 .170 .190
ADVANCE TECHNICAL INFORMATION
The product presented herein is under development. The Technical Specifications offered are
derived from a subjective evaluation of the design, based upon prior knowledge and experi-
ence, and constitute a "considered reflection" of the anticipated result. IXYS reserves the right
to change limits, test conditions, and dimensions without notice.